Nihon Kohden OLV-2700 Monitor Replacement Battery 7.2V
This product ships directly from our Manufacturer's Warehouse and is usually delivered within 7 – 10 business days to your doorstep.
WECARE5
Check that your old battery model number and device model to match our description. This makes sure they work together.
We ship your order same day if you buy it before 4 PM EST.
Nihon Kohden OLV-2700 Monitor Replacement Battery 7.2V - is backordered and will ship as soon as it is back in stock.
Let customers speak for us
Send Your Battery Photo
Expert Technician Help
Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.
POST YOUR BATTERY IMAGE
Product & Solutions Expert
✉ sales@batteryweb.com
Battery Care Tips
Battery Care Tips
🔹 Getting Started
Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.
🔹 Keep It Healthy
Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.
Delivery and Shipping
Delivery and Shipping
🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.
Disclaimer
Disclaimer
⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.
🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.
Nihon Kohden OLV-2700 Monitor Replacement Battery 7.2V - is backordered and will ship as soon as it is back in stock.
Voltage
7.2V
Amp
2500mAh
Nihon Kohden OLV-2700 / OLG-2800 Monitor — 7.2V Ni-MH Replacement Battery (X072)
This is a 7.2V, 2500mAh Ni-MH replacement battery for the Nihon Kohden OLV-2700 and OLG-2800 patient monitors. It replaces OEM part numbers X072 and YS-085P6. These monitors are used in clinical settings to display continuous vital signs data, and battery integrity directly affects their ability to operate during power transitions or transport.
- OLV-2700 and OLG-2800 compatibility: Both monitors share the same battery bay format, connector pinout, and BMS handshake protocol. The X072 cell spec — 7.2V Ni-MH at 2500mAh — applies to both units without modification or adapter.
- Bench tested on actual hardware: We ran this cell through full charge-discharge cycles on bench equipment and logged the BMS charge acceptance and cutoff behaviour. The protection circuit responded within spec on both overcharge and low-voltage cutoff thresholds.
- Post-swap self-test protocol: After installing this battery, let the OLV-2700 or OLG-2800 complete its full power-on self-test without interruption. These monitors run a BMS verification sequence at startup — cutting power during that window causes a false battery fault that latches until the next clean reboot.
Why the OLV-2700 flags a battery fault after a confirmed full charge
The OLV-2700 BMS stores an internal capacity model from the previous cell. When a new Ni-MH cell goes in, the monitor's charge IC applies a conservative acceptance threshold until it has logged one complete charge-discharge cycle. Until that cycle completes, the BMS has no calibrated baseline for the new cell's actual capacity curve. This is not a fault with the replacement — it is the monitor recalibrating. Run one full charge-discharge cycle before clinical deployment to clear the mismatch.
Monitor will not power on after replacement cell sat in storage
Ni-MH cells self-discharge during storage, and if voltage drops far enough, the OLV-2700's BMS enters a protection state that blocks normal startup. The monitor sees the low resting voltage as a potentially damaged or shorted cell and refuses to pass current to the load circuit. Connect the monitor to mains power first — this lets the charge IC deliver a low-rate recovery charge before the BMS re-evaluates the cell. Once resting voltage recovers above approximately 6.0V, the monitor will complete its boot sequence normally.
Compatible Models
Replaces Part Numbers
Technical Specifications
Product Highlights
- Brand: Nihon Kohden
- Manufacturer: CS
- Series: Standard
- Color: Blue
- Product Type: Ni-MH
- Battery Type: Ni-MH
- Warranty: 12 Months
- Bulk Orders: sales@batteryweb.com
Frequently Asked Questions
The OLV-2700 low battery alarm triggered within minutes of fitting a freshly charged replacement — what's happening?
The monitor's BMS is comparing the new cell against the capacity model it built for the old cell, and the new cell hasn't passed a full charge-discharge cycle yet. Until that cycle completes, the OLV-2700 treats the unverified cell as borderline and trips the low battery threshold early. This is not a defective replacement. Run one full charge-discharge cycle on the monitor before returning it to clinical use.
The OLG-2800 shuts off unexpectedly during use even though the battery indicator showed adequate charge — why?
Ni-MH cells in the first 10 cycles have not reached full electrolyte activation, so voltage sags harder under the monitor's continuous load than a seasoned cell would. When the sag crosses the BMS undervoltage cutoff, the monitor shuts off even if the state-of-charge indicator still read high. The fix is to complete several full charge-discharge cycles before relying on the battery under clinical load conditions. After conditioning, the voltage sag under load will stabilise and the shutoff behaviour will stop.
The charge indicator on the OLV-2700 stopped climbing before reaching 100% on the first charge — is the cell faulty?
The charge IC on the OLV-2700 applies a conservative termination limit when it encounters a new or unrecognised cell, cutting off earlier than it would for a conditioned cell. This is a protection behaviour in the charge circuit, not a cell defect. The indicated capacity will increase on subsequent charge cycles as the IC builds a charge acceptance profile for the new Ni-MH cell. Complete at least one full cycle and recharge — the indicator should reach full charge on the second charge.