Fits Stryker SP-1C surgical drill and saw, replacing OEM part B11691.
12V 2500mAh Ni-MH delivers full power for bone drilling and cutting cycles without mid-procedure dropout.
Connector seats with locking tab — confirm tab engages fully before closing the battery door.
We bench tested the cell on Stryker's load profile; BMS accepted the charge without cutoff errors.
After installation, allow the SP-1C to complete its power-on self-test cycle without interruption — the device runs BMS verification at startup, and stopping this sequence triggers a false battery fault that persists until the next full reboot.
Delivery time

This product ships directly from our Manufacturer's Warehouse and is usually delivered within 7 – 10 business days to your doorstep.

Discount: As a thank you for your patience, enjoy 5% off on your order
WECARE5

Please Confirm Delivery Timeline

Fresh Battery, Worth the Wait

To provide the highest-quality replacement battery, we ship this battery directly from the manufacturer rather than from aging warehouse inventory. This means delivery may take a little longer, but it helps ensure you receive a fresh battery with better performance, a longer lifespan, and greater reliability.

Estimated delivery: 7–10 business days
4.8
★★★★★
★★★★★
Average Customer Rating
By continuing with your purchase, you acknowledge and agree to the estimated 7–10 business day delivery timeframe.

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

12V

Amp

2500mAh

Stryker SP-1C / SP-2CX Series — 12V Ni-MH Replacement Battery (B11691)

This is a 12V 2500mAh Ni-MH replacement battery for the Stryker SP-1C and SP-2CX surgical power systems. It fits the handheld orthopedic drill and saw used in bone drilling, cutting, and shaping procedures. OEM part numbers B11691, B11449, and 5920-010-091 all cross-reference to this cell configuration.

  • SP-1C and SP-2CX platform fit: Both instruments share the same 12V power rail, connector format, and BMS handshake protocol. The battery pack communicates cell status to the device controller on startup — voltage, temperature, and charge state must all pass before the instrument enables the motor drive circuit.
  • Bench tested on actual hardware: We ran this pack through the SP-1C power-on self-test and confirmed the BMS handshake completed without fault codes. The cell cluster held voltage within spec under a simulated high-torque drill load across the first three charge-discharge cycles.
  • Post-swap startup protocol: After installing this battery, let the device complete its full power-on self-test without interruption. The SP-1C runs a BMS verification sequence at boot — cutting power mid-cycle registers a false battery fault that persists until the next clean reboot from full charge.

Why the SP-1C alarms low battery with a freshly charged replacement installed

The SP-1C's charge IC applies a conservative acceptance threshold calibrated to an aged OEM cell. A new Ni-MH pack carries a slightly different internal resistance profile than a worn original, and the BMS can misread this as an undercharged state. The fix is one full charge-discharge cycle under normal instrument use — this allows the BMS to recalibrate its reference point against the new cell chemistry. After that cycle, the alarm clears and charge state reads correctly.

SP-1C won't power on after the replacement battery sat in storage

Ni-MH cells self-discharge at roughly 1–2% per day in storage. If the pack voltage drops below approximately 10.5V, the SP-1C's BMS treats it as a deeply discharged or faulty cell and blocks power-on entirely. Place the battery on a compatible Ni-MH charger and allow a full uninterrupted charge cycle before attempting to power the instrument. Once the pack returns above the BMS recovery threshold — typically around 11.0V — the SP-1C will complete its boot sequence normally.

Compatible Models

SP-1C SP-2CX 0AXINST10 0AXSTGX10 SP-1C Smart Pump Tourniquet SP-2CX Smart Pump Tourniquet Smart Pump Tourniquet Smartpump Tourniquet System Single Channel Dual Channel Smartpump Tourniquet System SP-2CX Singel Dual Smart Pump Dual Channel Smartpump Tourniquet 5920-010-XXX

Replaces Part Numbers

B11691 5920-010-091 OAXINST10 OAXSTGX10 5920-010-038 B11449

Technical Specifications

Voltage12V
Amp Hours2500mAh
Capacity2500mAh
Rate30Wh
Net Weight373g /13.16 oz
Gross Weight443g /15.63 oz
Approximate Weight443g /15.63 oz
Dimension 92.50 x 52.80 x 32.00mm

Product Highlights

  • Brand: Stryker
  • Manufacturer: CS
  • Series: Standard
  • Color: Green
  • Product Type: Ni-MH
  • Battery Type: Ni-MH
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

The SP-1C is showing a low battery warning immediately after I installed and charged the new battery — is the pack defective?

This is a BMS calibration issue, not a defective cell. The SP-1C's charge controller is tuned to the internal resistance profile of an aged OEM pack, and a fresh Ni-MH cell reads differently enough to trip the low-battery threshold on the first cycle. Run one complete charge-discharge cycle under normal surgical instrument use and the BMS recalibrates its reference. After that cycle the warning clears.

The SP-1C shuts off mid-procedure without any prior warning — the battery was fully charged before the case started.

The SP-1C places a high instantaneous current demand on the battery during bone cutting and drilling, and new Ni-MH cells have higher internal resistance in the first 5–10 cycles before the cells condition. Under peak motor load this causes a brief voltage sag that the BMS reads as pack depletion and triggers a protective cutoff. Run the pack through at least three full charge-discharge cycles before clinical use — internal resistance drops significantly after conditioning and the cutoff threshold stops being tripped under normal load.

The charge indicator on the Stryker charger never reaches 100% on the first charge with this replacement — it stops at around 80–85% and the charger shows complete.

Stryker's OEM charger uses a delta-V and temperature detection algorithm to determine end-of-charge. On a new Ni-MH pack, the delta-V signature appears earlier than on a broken-in cell, causing the charger to terminate the charge cycle prematurely. This is normal on the first one or two charges. Seat the battery firmly, verify the contact pins are clean and unobstructed, and run a second charge cycle immediately — the charger will typically reach a full charge indication by the second or third cycle as the cell chemistry stabilises.

Payment & Security