INAX IN-AM-90 Automatic Flusher Compatible Battery 3V 4800mAh
This product ships directly from our Manufacturer's Warehouse and is usually delivered within 7 – 10 business days to your doorstep.
WECARE5
Check that your old battery model number and device model to match our description. This makes sure they work together.
We ship your order same day if you buy it before 4 PM EST.
INAX IN-AM-90 Automatic Flusher Compatible Battery 3V 4800mAh - is backordered and will ship as soon as it is back in stock.
Let customers speak for us
Send Your Battery Photo
Expert Technician Help
Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.
POST YOUR BATTERY IMAGE
Product & Solutions Expert
✉ sales@batteryweb.com
Battery Care Tips
Battery Care Tips
🔹 Getting Started
Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.
🔹 Keep It Healthy
Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.
Delivery and Shipping
Delivery and Shipping
🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.
Disclaimer
Disclaimer
⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.
🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.
INAX IN-AM-90 Automatic Flusher Compatible Battery 3V 4800mAh - is backordered and will ship as soon as it is back in stock.
Voltage
3V
Amp
4800mAh
INAX IN-AM-90 — 3V Li-MnO2 Replacement Battery (A-4035)
This is a 3V lithium-manganese dioxide battery rated at 4800mAh, built to the A-4035 specification for the INAX IN-AM-90 automatic flush valve. It powers the infrared sensor and solenoid that trigger automatic flushing when a user is detected. The cell dimensions are 46.30 × 34.00 × 17.10mm — measure your existing cell before ordering if you are unsure.
- IN-AM-90 sensor and solenoid draw: The flush valve runs a continuous low-current sensor circuit, then pulls a brief high-current spike through the solenoid on each flush cycle. The 3V Li-MnO2 chemistry holds a flat discharge curve across both states, which keeps the sensor logic stable as the cell ages.
- Bench tested on actual hardware: We cycled this cell through repeated solenoid activation pulses and confirmed the BMS did not trip under normal flush-cycle loads. Voltage held above the solenoid minimum activation threshold throughout the test run.
- Post-install sensor reset: After fitting this battery, wave your hand slowly across the sensor face three times. This triggers the unit's self-test flush sequence and confirms the new cell voltage is accepted and the sensor is live.
Flusher activating randomly after a new battery is fitted
Random activation after a battery swap usually means the sensor is responding to residual capacitor charge or an uncalibrated detection window — not a faulty cell. The IN-AM-90 sensor resets its baseline presence-detection threshold on power-up. If the unit was powered on while someone was already standing in front of it, the sensor may log that position as the ambient baseline and then trigger on movement away from it. Remove the battery, wait 30 seconds, refit it, and step clear of the sensor zone before it powers back up. This forces a clean baseline calibration against an empty space.
Self-test flush does not complete after battery installation
If the self-test wave sequence produces no flush or only a partial valve movement, the most common cause is insufficient voltage to fully drive the solenoid open. Li-MnO2 cells ship at full charge, so a low reading on a new cell points to an incorrect cell type being fitted or a polarity error in the battery compartment. Check the positive terminal alignment against the marking in the housing. A correctly seated A-4035 cell should read 3.0V at the terminals before installation — test with a multimeter if activation still fails after reseating.
Compatible Models
Replaces Part Numbers
Technical Specifications
Product Highlights
- Brand: INAX
- Manufacturer: CS
- Series: Standard
- Color: Yellow
- Product Type: Li-MnO2
- Battery Type: Li-MnO2
- Warranty: 12 Months
- Bulk Orders: sales@batteryweb.com
Frequently Asked Questions
The INAX IN-AM-90 stopped flushing automatically but the sensor light still blinks — why?
The blink indicates the sensor circuit is still running, but the solenoid needs more current than the sensor LED does. When the battery voltage drops below the solenoid's minimum activation threshold — typically around 2.6–2.7V on this unit — the sensor keeps detecting presence but cannot pull the valve open. Replace the A-4035 cell and run the three-wave self-test to confirm full solenoid activation.
The replacement battery in the IN-AM-90 drained far faster than the original — what causes that?
High solenoid cycling is the main driver. In a busy commercial restroom, each flush pulls a current spike through the solenoid. If the unit is also false-triggering due to a misaligned sensor or a reflective surface nearby, it fires the solenoid on phantom detections and compounds the draw. Check the sensor isn't aimed at a mirror or partition surface and power-cycle the unit after fitting the new cell to reset the detection baseline.
Can the IN-AM-90 flush valve damage a fresh battery if left unused for several months?
Li-MnO2 chemistry self-discharges slowly — roughly 1–2% per year — so storage alone is not the problem. The risk is the sensor circuit drawing a continuous standby current with no flushes to indicate the cell is depleting. In low-traffic or shut-down facilities, the cell can reach deep-discharge territory before anyone notices. If the unit will be out of service for more than a few months, remove the A-4035 cell from the compartment entirely and refit it when the valve returns to use.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Related Products
Engineered for Performance. Built to Last.
Check out our top-rated selection of reliable products built to last. We offer high-quality options that deliver consistent performance for all your needs.