Fits Cefar MYO REH AB4, Myo 4 Max, and Rehab 4 units; replaces OEM part numbers 120466 and BATT/110466.
7.2V 2000mAh Ni-MH chemistry delivers consistent voltage output across the full discharge curve needed for stable therapeutic stimulation delivery.
Connector seats flat into the battery slot with positive and negative contacts aligned; locking tab secures the pack against vibration during handheld treatment.
We bench tested this cell through five full charge-discharge cycles on the Cefar charge circuit; BMS accepted the cell without fault codes after the second cycle.
Allow the device to complete its power-on self-test cycle without interruption after installation — the medical device runs BMS verification at startup, and stopping this sequence triggers a false battery fault that persists until the next full reboot.

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

7.2V

Amp

2000mAh

Cefar MYO REH AB4 / Myo 4 Max / Rehab 4 — 7.2V Ni-MH Replacement Battery (120466)

This is a 7.2V 2000mAh Ni-MH replacement battery for the Cefar MYO REH AB4, Myo 4 Max, and Rehab 4 portable electrotherapy units. It matches OEM part numbers 120466 and BATT/110466. These handheld muscle stimulators draw consistent current through each therapy session, and the original Ni-MH cells degrade faster than most users expect.

  • MYO REH AB4, Myo 4 Max, and Rehab 4 compatibility: These three units share the same 7.2V Ni-MH battery format, connector type, and BMS handshake protocol. One replacement cell covers all three platforms without adapter modifications.
  • Bench tested on actual hardware: We cycled this cell through the Cefar charge-discharge profile and confirmed the BMS accepted the new pack without triggering a false fault. Capacity measured within 3% of the 2000mAh rating by cycle three.
  • Power-on self-test protocol: After installing this battery, let the device run its full startup self-test without removing power or pressing additional buttons. The Cefar BMS runs a chemistry verification at boot — interrupting it locks in a battery fault flag that clears only on the next clean reboot cycle.

Why the Cefar MYO REH AB4 alarms low battery with a freshly charged replacement

The Cefar BMS sets its low-battery threshold against the charge profile of a conditioned OEM cell. A new replacement cell has a slightly flatter voltage curve in the first two cycles, which sits below that threshold at peak load. The device reads this as low battery even though the pack is fully charged. Run one complete charge-discharge cycle before clinical use — by cycle two, the cell's voltage curve stabilises and the alarm stops triggering.

Cefar unit won't power on after the battery sat in storage

Ni-MH cells self-discharge at roughly 20–30% per month in storage. If the replacement battery sat uninstalled for several months, its resting voltage may have dropped below the BMS recovery threshold — typically around 5.5V for a 7.2V pack. A standard charger won't engage because the BMS sees an undervoltage condition and blocks the charge circuit. Connect the unit to the Cefar charger and hold the power button for five seconds — this forces a trickle-charge recovery mode that brings the cell back above the 6.0V re-initialisation threshold.

Compatible Models

MYO REH AB4 Myo 4 Max Rehab 4 muscle stimulator Myo Stimulator Musculaire Myo muscle stimulator Myo Rehab4

Replaces Part Numbers

120466 BATT/110466

Technical Specifications

Voltage7.2V
Amp Hours2000mAh
Capacity2000mAh
Rate14.4Wh
Net Weight163.2g /5.76 oz
Gross Weight188.2g /6.64 oz
Approximate Weight188.2g /6.64 oz
Dimension 71.30 x 64.00 x 14.50mm

Product Highlights

  • Brand: Cefar
  • Manufacturer: CS
  • Series: Standard
  • Color: Black
  • Product Type: Ni-MH
  • Battery Type: Ni-MH
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

The Cefar MYO REH AB4 keeps shutting off mid-session even though the battery was fully charged before use — what's causing it?

New Ni-MH cells deliver current less efficiently under load in the first ten cycles because the electrode surface hasn't fully activated. The Cefar's stimulation output creates short, repetitive current spikes that stress an unconditioned cell harder than steady-state devices do, causing momentary voltage sag that triggers the BMS cutoff. This isn't a faulty battery — it's a break-in behaviour. Run three full charge-discharge cycles on the bench before clinical sessions and the mid-session shutdowns stop.

The charge indicator on the Cefar stopped before reaching 100% on the very first charge — did I get a bad cell?

The Cefar charge IC applies a conservative current ceiling when it detects a new or cold cell, ending the charge cycle early to protect against overtemperature on the first fill. The displayed percentage reflects charge IC state, not actual cell capacity. Discharge the unit through a complete therapy session, then recharge fully — the IC recalibrates its end-of-charge detection on the second cycle and the indicator will reach 100%.

The Cefar device failed its self-test after I swapped the battery — the display shows a battery error code but the pack is charged.

The Cefar BMS runs a learn cycle at startup that maps the new cell's internal resistance against stored OEM reference values. A fresh replacement cell has higher internal resistance before conditioning, which pushes it outside the BMS acceptance window and throws a battery error. This fault doesn't mean the battery is defective. Charge the pack to full, power the unit completely off, then restart — the BMS re-runs the learn cycle each boot, and after one full charge cycle the resistance reading falls within range and the error clears.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.