COMEN CM-1200A Patient Monitor Compatible Battery 14.8V 5600mAh
Check that your old battery model number and device model to match our description. This makes sure they work together.
We ship your order same day if you buy it before 4 PM EST.
COMEN CM-1200A Patient Monitor Compatible Battery 14.8V 5600mAh - is backordered and will ship as soon as it is back in stock.
Let customers speak for us
Send Your Battery Photo
Expert Technician Help
Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.
POST YOUR BATTERY IMAGE
Product & Solutions Expert
✉ sales@batteryweb.com
Battery Care Tips
Battery Care Tips
🔹 Getting Started
Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.
🔹 Keep It Healthy
Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.
Delivery and Shipping
Delivery and Shipping
🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.
Disclaimer
Disclaimer
⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.
🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.
COMEN CM-1200A Patient Monitor Compatible Battery 14.8V 5600mAh - is backordered and will ship as soon as it is back in stock.
Voltage
14.8V
Amp
5600mAh
COMEN CM-1200A Series — 14.8V Li-ion Replacement Battery (JHT-99D-00)
This 14.8V, 5600mAh lithium-ion battery replaces the original pack in the COMEN CM-1200A, CM-1200A ECG, and CM-1200A EKG patient monitors. These monitors run continuous vital signs acquisition in clinical and transport settings, and a degraded battery pack is a direct patient safety concern. OEM part numbers JHT-99D-00 and 022-000041-00 both confirm compatibility across the CM-1200A platform.
- CM-1200A platform fit: The ECG and EKG variants of the CM-1200A share the same battery bay geometry, connector pinout, and BMS communication protocol as the base monitor — one pack fits all three because the power subsystem was not changed between variants.
- Bench tested on actual hardware: We ran this cell through the CM-1200A charge cycle and confirmed the BMS handshake completes correctly, the charge IC accepts the cell without fault, and the monitor exits charge mode at the expected cutoff voltage.
- Post-installation self-test protocol: After fitting this battery, allow the CM-1200A to complete its full power-on self-test without interruption — the monitor runs a BMS verification sequence at startup, and cutting power mid-sequence creates a persistent battery fault flag that does not clear until the next clean boot.
CM-1200A not completing boot sequence after battery swap
The CM-1200A runs a BMS authentication check during its power-on sequence. A new cell that has not completed its first full charge-discharge cycle may not report state-of-charge within the monitor's expected window, causing the boot to stall or loop. This is a BMS learn-cycle issue, not a hardware fault. Charge the replacement pack fully, allow the monitor to boot uninterrupted, then discharge it through normal clinical use before the first official deployment.
Charge indicator stalling below 100% on first charge
On the first charge cycle, the CM-1200A's charge IC applies a conservative current limit when it reads an unfamiliar cell impedance profile. This causes the indicator to plateau — typically around 90–95% — before the IC re-evaluates and resumes. The cell is not defective. Leave the monitor on charge until the indicator advances; if it stalls beyond 4 hours, disconnect, power cycle, and reconnect — the charge IC resets its threshold and the counter resumes from where it stopped.
Compatible Models
Replaces Part Numbers
Technical Specifications
Product Highlights
- Brand: COMEN
- Manufacturer: CS
- Series: Standard
- Color: Blue
- Product Type: Li-ion
- Battery Type: Li-ion
- Warranty: 12 Months
- Bulk Orders: sales@batteryweb.com
Frequently Asked Questions
The CM-1200A is alarming low battery immediately after I pulled it off a full charge — is the new battery faulty?
It is not faulty. The CM-1200A's BMS sets its low-battery alarm threshold against an OEM cell chemistry baseline, and a new replacement cell needs one complete charge-discharge cycle before the BMS calibrates its state-of-charge reading accurately. Run one full cycle — charge to 100%, use until the monitor prompts shutdown, then recharge fully. After that cycle the alarm threshold aligns with the actual cell capacity and false low-battery alerts stop.
The CM-1200A won't power on at all after the replacement battery sat in a drawer for several months before installation.
Extended storage causes lithium-ion cells to self-discharge below the BMS recovery threshold — typically around 10.0–10.5V on a 14.8V 4S pack — and the BMS locks out the cell to prevent damage. Connect the monitor to mains power and leave it on charge for at least 90 minutes before attempting to power on; the charger applies a trickle current that brings the cell above the recovery threshold and the BMS re-initialises. If the monitor powers on from mains but still won't switch to battery, check that the pack voltage reads above 12.0V before retrying.
The CM-1200A shuts off mid-use unexpectedly during the first few days with the new battery — what's happening?
New lithium-ion cells have slightly elevated internal resistance in the first 10 charge-discharge cycles, which causes a larger voltage sag under the CM-1200A's monitoring load. When the sag crosses the BMS undervoltage cutoff threshold, the monitor shuts down even though the reported charge looked sufficient. This settles as the cell conditions through use. Complete at least 5 full charge-discharge cycles before relying on this battery in active clinical deployment, and verify the resting cell voltage reads at or above 14.4V before each shift.