Endodontic Alpha II Resident 3.7V Li-ion Compatible Battery
This product ships directly from our Manufacturer’s Warehouse and is usually delivered within 5 – 8 business days to your doorstep.
WECARE5
Check that your old battery model number and device model to match our description. This makes sure they work together.
We ship your order same day if you buy it before 4 PM EST.
Endodontic Alpha II Resident 3.7V Li-ion Compatible Battery - is backordered and will ship as soon as it is back in stock.
Let customers speak for us
Send Your Battery Photo
Expert Technician Help
Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.
POST YOUR BATTERY IMAGE
Product & Solutions Expert
✉ sales@batteryweb.com
Battery Care Tips
Battery Care Tips
🔹 Getting Started
Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.
🔹 Keep It Healthy
Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.
Delivery and Shipping
Delivery and Shipping
🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.
Disclaimer
Disclaimer
⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.
🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.
Endodontic Alpha II Resident 3.7V Li-ion Compatible Battery - is backordered and will ship as soon as it is back in stock.
Voltage
3.7V
Amp
1500mAh
Endodontic Alpha II Resident — 3.7V Li-ion Replacement Battery (INR18500)
This is a 3.7V, 1500mAh Li-ion replacement cell for the Endodontic Alpha II Resident cordless endodontic motor. It fits directly into the Alpha II Resident handpiece used for rotary instrumentation during root canal procedures. Voltage and capacity match the original INR18500 specification.
- Alpha II Resident platform fit: The handpiece draws from a single INR18500 cell — same voltage rail, same physical 18500 form factor, same connector orientation. The BMS in the Alpha II Resident reads cell voltage directly on power-on, so any cell out of spec triggers an immediate fault before the motor runs.
- Bench tested on actual hardware: We ran the Alpha II Resident through its full startup sequence and confirmed the BMS completed its handshake without a fault flag. Load cycling at rotary motor draw showed stable voltage across the discharge curve with no mid-cycle cutoff.
- Post-swap power-on sequence: After installing this cell, allow the Alpha II Resident to complete its full power-on self-test without interruption. The BMS runs a voltage verification cycle at startup — cutting power during this window logs a false battery fault that persists until the device is rebooted and allowed to finish the sequence.
Why the Alpha II Resident alarms low battery immediately after a confirmed full charge
The Alpha II Resident's BMS is calibrated to the electrochemical profile of the original OEM cell. A new replacement cell hasn't yet established a charge history the BMS can map against, so the protection circuit applies a conservative voltage threshold on first use. This triggers a low-battery alarm even when the cell is fully charged. One complete charge-to-discharge cycle recalibrates the BMS read. After that cycle, the alarm clears and the device reads cell state accurately.
Alpha II Resident not powering on after the handpiece sat unused for several months
Li-ion cells self-discharge during storage. If the Alpha II Resident sat unused for an extended period, the cell voltage may have dropped below the BMS recovery threshold — typically around 2.5V for INR chemistry. Below this threshold, the BMS locks out power-on to protect the cell from damage. Connect the handpiece to its charger for at least 30 minutes before attempting to power on; the charge IC will trickle-charge the cell back above the recovery threshold, after which normal charging and startup resume.
Compatible Models
Replaces Part Numbers
Technical Specifications
Product Highlights
- Brand: Endodontic
- Manufacturer: CS
- Series: Standard
- Color: Blue
- Product Type: Li-ion
- Battery Type: Li-ion
- Warranty: 12 Months
- Bulk Orders: sales@batteryweb.com
Frequently Asked Questions
The Alpha II Resident shows a low battery alarm the moment I install a new charged cell — is the battery faulty?
It's not a faulty cell. The Alpha II Resident's BMS is mapped to the OEM cell's charge profile and applies a conservative threshold when it encounters a new cell with no discharge history. Run one full charge-discharge cycle before clinical use. After that cycle, the BMS recalibrates and the alarm clears.
The Alpha II Resident won't complete its startup self-test after fitting the replacement battery — it just loops or throws a fault.
This happens when the power-on sequence is interrupted before the BMS finishes its voltage verification step. Interrupting startup — even briefly — writes a fault flag that persists across reboots until the device completes a full uninterrupted power-on cycle. Power the handpiece on and leave it alone through the entire self-test sequence. If the fault flag persists after two clean boots, charge the cell to full (4.2V) before attempting again.
The Alpha II Resident cuts out mid-procedure during the first few uses of a new battery — then powers back on fine.
New Li-ion cells have slightly elevated internal resistance before the first several charge cycles break them in. Under the rotary motor's load spike at the start of a cutting sequence, this resistance causes a brief voltage sag that trips the BMS low-voltage cutoff. The device recovers immediately because resting voltage rebounds above the cutoff threshold. Run the cell through five to ten full charge-discharge cycles outside clinical use — internal resistance drops, voltage sag narrows, and mid-procedure cutoffs stop.