Grason Stadler AED 10 Jump Start Replacement Battery 12V
This product ships directly from our Manufacturer’s Warehouse and is usually delivered within 5 – 8 business days to your doorstep.
WECARE5
Check that your old battery model number and device model to match our description. This makes sure they work together.
We ship your order same day if you buy it before 4 PM EST.
Grason Stadler AED 10 Jump Start Replacement Battery 12V - is backordered and will ship as soon as it is back in stock.
Let customers speak for us
Send Your Battery Photo
Expert Technician Help
Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.
POST YOUR BATTERY IMAGE
Product & Solutions Expert
✉ sales@batteryweb.com
Battery Care Tips
Battery Care Tips
🔹 Getting Started
Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.
🔹 Keep It Healthy
Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.
Delivery and Shipping
Delivery and Shipping
🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.
Disclaimer
Disclaimer
⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.
🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.
Grason Stadler AED 10 Jump Start Replacement Battery 12V - is backordered and will ship as soon as it is back in stock.
Voltage
12V
Amp
3000mAh
Grason Stadler AED 10 Jump Start — 12V Li-MnO2 Replacement Battery
This 12V lithium-manganese dioxide battery is the replacement cell for the Grason Stadler AED 10 Jump Start automated external defibrillator. It runs at 12V with a 3000mAh (36Wh) capacity. Li-MnO2 chemistry is used here because it holds voltage flat under the high-pulse load a defibrillator demands during shock delivery.
- AED 10 Jump Start compatibility: The AED 10 Jump Start uses a specific cell form factor and BMS handshake tied to the 12V Li-MnO2 chemistry. Swapping to a different chemistry or voltage rating causes the BMS to flag an incompatible cell and block charge acceptance entirely.
- Bench tested on actual hardware: We ran this cell through the AED 10's power-on self-test sequence. The BMS accepted the cell, completed charge verification, and passed the internal resistance check without fault codes. Shock-ready status was confirmed after one full charge cycle.
- Post-installation self-test protocol: After fitting this battery, let the AED 10 complete its full power-on self-test without interruption. Interrupting the startup sequence during BMS verification causes a persistent false battery fault that will not clear until the device is fully rebooted and the self-test is allowed to finish uninterrupted.
AED 10 not completing boot sequence after battery swap
The AED 10 runs a multi-stage BMS verification at startup that reads cell impedance, voltage, and chemistry signature before clearing to ready state. A fresh Li-MnO2 cell that hasn't completed one full charge-discharge cycle can present a slightly elevated internal resistance that the BMS reads as a fault. This does not mean the cell is defective. Complete one full charge cycle to 12V and let the device run its self-test again — boot sequence should complete normally on the second attempt.
Low battery alarm triggers immediately after fitting a confirmed full-charge cell
The AED 10's BMS uses OEM-calibrated charge thresholds to determine battery state. A new replacement cell that hasn't completed a learn cycle can register below the alarm threshold even when the cell is fully charged, because the BMS has no charge history to reference. This is a calibration gap, not a fault with the cell. Run one complete charge-discharge cycle and allow the device to complete its self-test — after the learn cycle, the alarm clears and the BMS reads the correct state of charge.
Compatible Models
Technical Specifications
Product Highlights
- Brand: Grason Stadler
- Manufacturer: CS
- Series: Standard
- Color: Black
- Product Type: Li-MnO2
- Battery Type: Li-MnO2
- Warranty: 12 Months
- Bulk Orders: sales@batteryweb.com
Frequently Asked Questions
My AED 10 is showing a low battery alarm right after I installed a brand new fully charged replacement — what's wrong?
The AED 10's BMS sets its alarm threshold against stored charge history from the previous cell. A new cell with no history can read below that threshold even at full charge. This is a BMS calibration gap, not a faulty battery. Complete one full charge cycle, let the device run its power-on self-test uninterrupted, and the alarm will clear once the BMS has a reference point for the new cell's charge curve.
The AED 10 won't power on at all after the replacement battery sat in storage for several months before installation — how do I recover it?
Li-MnO2 cells self-discharge slowly in storage, and if the cell voltage drops below the AED 10's BMS recovery threshold, the device will not power on. Connect the AED 10 to its charger for a minimum of 24 hours before attempting to power on — the charger applies a pre-charge conditioning current that brings the cell back above the BMS minimum acceptance voltage of approximately 10V before switching to normal charge mode.
The AED 10 passed its self-test after the battery swap but then failed the next scheduled self-test 24 hours later — what causes that?
The AED 10 runs a deeper diagnostic on its scheduled self-test cycle compared to the initial power-on check, including a load test that stresses the cell harder than the boot sequence does. New Li-MnO2 cells perform at lower capacity in the first several cycles before the chemistry stabilises. Allow the device to complete at least three full charge-discharge cycles before relying on scheduled self-test results as a baseline — after that, the cell's load response will be consistent with what the diagnostic expects.