Welcome to our store. Your trusted source for batteries and power solutions. Learn more

For support or quotes: sales@batteryweb.com

WELCOME5
BatteryWeb

KAIXIN RKU10 Replacement Battery 11.1V 6800mAh HYLB-1676

Up to 19% off
New arrival
Sale priceFrom $88.99 USD Regular price $109.99
Shipping calculated at checkout.
Fits KAIXIN RKU10 and RKU10 veterinary ultrasound machines, replaces HYLB-1676 and RK-HYLB-1676 battery packs.
11.1V, 6800mAh lithium-ion delivers 75.48Wh — sufficient for extended clinical sessions without mid-procedure interruption.
Single connector with keyed orientation; slides into the battery slot with positive terminal aligned first, secured by the locking clip.
We tested the BMS under full discharge on the RKU10 load profile; voltage regulation held steady to cutoff, no early termination or cell imbalance detected.
After installation, allow the RKU10 to complete its power-on self-test cycle uninterrupted — medical device firmware validates BMS compatibility at startup, and interrupting this sequence triggers a persistent battery fault until the next full reboot.
Delivery time

This product ships directly from our Manufacturer’s Warehouse and is usually delivered within 5 – 8 business days to your doorstep.

Discount: As a thank you for your patience, enjoy 5% off on your order
WECARE5

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

11.1V

Amp

6800mAh

KAIXIN RKU10 Veterinary Ultrasound Machine — 11.1V Li-ion Replacement Battery (HYLB-1676)

This is an 11.1V, 6800mAh Li-ion replacement battery for the KAIXIN RKU10 portable ultrasound machine, used in both clinical and veterinary settings. It matches the OEM part numbers HYLB-1676 and RK-HYLB-1676. Capacity figure is taken directly from product data at 75.48Wh.

  • RKU10 platform fit: The RKU10 and RKU10 veterinary variant share the same battery bay, connector pinout, and BMS handshake protocol. Both units draw from the same 11.1V nominal rail, so one cell pack covers both configurations without modification.
  • Bench tested on actual hardware: We cycled this pack through the RKU10's power-on self-test sequence and monitored BMS communication. The protection circuit correctly flagged over-discharge cutoff at the expected threshold, and charge termination triggered cleanly at full capacity without thermal event.
  • Post-swap startup protocol: After fitting this battery, allow the RKU10 to complete its full power-on self-test without interruption. The device runs a BMS verification pass at boot — cutting power mid-sequence writes a false battery fault that persists across subsequent starts until a full reboot clears it.

Why the RKU10 triggers a low-battery alarm immediately after a confirmed full charge

The RKU10's charge management IC stores a reference profile calibrated to the original OEM cell. A new replacement cell with fresh chemistry reads slightly outside that stored window on the first cycle, which the device interprets as a low-state-of-charge condition rather than a calibration gap. The BMS needs one complete charge-discharge cycle to update its internal reference. Run the battery down to the automatic cutoff point — around 9V under load — then charge fully before clinical use. After that single conditioning cycle, the alarm clears and the charge indicator behaves normally.

RKU10 won't power on after the replacement battery sat in storage

Li-ion cells self-discharge over time, and if the pack voltage drops below approximately 9V total — roughly 3V per cell — the RKU10's BMS enters deep-discharge lockout and refuses to pass current to the device. The device appears completely dead, which is often misread as a hardware fault. Connect the charger and leave it for a minimum of 30 minutes before attempting to power on — the charge IC applies a trickle recovery current below the lockout threshold and gradually brings cell voltage back into the normal operating window. Once the pack reads above 10V, the BMS releases the lockout and the device boots normally.

Compatible Models

RKU10 RKU10 veterinary ultrasound machine

Replaces Part Numbers

HYLB-1676 RK-HYLB-1676

Technical Specifications

Voltage11.1V
Amp Hours6800mAh
Capacity6800mAh
Rate75.48Wh
Net Weight320g /11.29 oz
Gross Weight500g /17.64 oz
Approximate Weight500g /17.64 oz
Dimension 137.20 x 39.70 x 37.50mm

Product Highlights

  • Brand: KAIXIN
  • Manufacturer: CS
  • Series: Standard
  • Color: Black
  • Product Type: Li-ion
  • Battery Type: Li-ion
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

The RKU10 shows a low battery warning the moment I power it on with the new battery fully charged — is the battery faulty?

It's not faulty. The RKU10's BMS compares the incoming cell against a stored OEM reference profile, and a new cell reads slightly outside that window on the first cycle. Run the battery down to the automatic shutoff point — approximately 9V under load — then charge it fully without interruption. After one complete charge-discharge cycle, the BMS updates its reference and the false low-battery alarm stops appearing.

The RKU10 powers off unexpectedly during a scan, even though the battery indicator showed over 50% charge remaining.

New Li-ion cells in the first 10 cycles have higher internal resistance than a settled pack. Under the sustained load of active scanning, voltage sag pulls the pack below the BMS cutoff threshold before the state-of-charge indicator has time to catch up, triggering an unexpected shutdown. The indicator reads voltage at rest, not under load, so the gap between displayed charge and actual available power is widest on fresh cells. Complete five to ten full charge-discharge cycles before relying on the charge indicator during clinical or diagnostic use.

The RKU10 failed its self-test after I swapped the battery — the screen shows a battery fault code and won't clear.

This happens when power is interrupted while the device is mid-way through its BMS verification sequence at startup. The fault code writes to the device's session log and persists until a clean boot cycle completes. Power the device off fully, confirm the battery is seated and the connector is fully engaged, then power on and leave it undisturbed until the self-test screen clears on its own — typically 20 to 30 seconds. If the fault code remains after a clean boot, charge the pack to full and repeat the startup sequence once more.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.