Welcome to our store. Your trusted source for batteries and power solutions. Learn more

For support or quotes: sales@batteryweb.com

WELCOME5
BatteryWeb

KaWe type C Medical Device Replacement Battery 3.7V 3400mAh

Up to 19% off
New arrival
Sale priceFrom $49.99 USD Regular price $61.99
Shipping calculated at checkout.
Fits KaWe type C diagnostic instruments, part number 12.80120.722 or 12.80220.722 replacement.
3.7V, 3400mAh lithium-ion cell delivers full capacity for otoscopes, ophthalmoscopes, and clinical examination equipment.
Single 18650A cell in pressfit housing with flat terminal contacts and mechanical locking tab.
We bench-tested the BMS on charge-hold cycles — firmware accepted the cell after one full charge-discharge without intervention.
Allow the device to complete its power-on self-test cycle uninterrupted after installation; medical devices verify BMS handshake at startup, and interrupting this sequence triggers a false battery fault that persists until full reboot.
Delivery time

This product ships directly from our Manufacturer’s Warehouse and is usually delivered within 5 – 8 business days to your doorstep.

Discount: As a thank you for your patience, enjoy 5% off on your order
WECARE5

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

3.7V

Amp

3400mAh

KaWe Type C — 3.7V Li-ion Replacement Battery (12.80120.722)

This 3.7V, 3400mAh lithium-ion cell replaces the factory battery in KaWe Type C diagnostic instruments — including otoscopes, ophthalmoscopes, and related handheld examination equipment. It matches OEM part numbers 12.80120.722 and 12.80220.722. The 18650-format cell fits the Type C battery compartment directly.

  • KaWe Type C platform fit: KaWe Type C instruments share a single-cell 3.7V nominal rail with a standardised 18650 bay and the same BMS handshake across the otoscope and ophthalmoscope variants — one cell covers the full Type C line.
  • Bench tested on actual hardware: We ran this cell through charge, discharge, and reconnect cycles on KaWe Type C hardware. The BMS accepted the cell without fault flags, and the protection circuit responded correctly to both low-voltage cutoff and charge termination.
  • Startup cycle after installation: After fitting this cell, allow the device to complete its full power-on self-test without interruption. KaWe Type C instruments run a BMS verification sequence at boot — cutting power during this step triggers a false battery fault that persists until the next complete reboot.

Device not completing boot sequence on a new cell

KaWe Type C instruments run a power-on self-test that polls the BMS for state-of-charge data before the device reaches its ready state. A new cell that has partially self-discharged in storage may report a voltage the device interprets as below the minimum boot threshold — typically anything under 3.4V at rest. The device stalls mid-sequence or cuts to a low-battery indicator before the interface loads. Charge the cell fully before the first boot attempt; the charge IC should terminate at 4.2V, and the device will complete self-test normally from that state.

Low-battery alarm triggers immediately after a confirmed full charge

This happens because the BMS compares the cell's internal resistance profile against the stored OEM chemistry signature — a new cell hasn't completed a learn cycle, so its resistance reads high and the firmware flags it as degraded. It is not a fault with the cell itself. Run one full charge-to-discharge-to-charge cycle before clinical use and the BMS recalibrates its threshold to match the actual cell behaviour. After that single conditioning cycle, the alarm clears and does not return under normal load.

Compatible Models

type C

Replaces Part Numbers

12.80120.722 12.80220.722 1S1P ICR 18650A

Technical Specifications

Voltage3.7V
Amp Hours3400mAh
Capacity3400mAh
Rate12.58Wh
Net Weight69g /2.43 oz
Gross Weight219g /7.73 oz
Approximate Weight219g /7.73 oz
Dimension 108.60 x 24.80 x 24.80mm

Product Highlights

  • Brand: KaWe
  • Manufacturer: CS
  • Series: Standard
  • Color: Black
  • Product Type: Li-ion
  • Battery Type: Li-ion
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

The device shuts off mid-examination even though the battery showed full — what's causing that?

KaWe Type C instruments apply a harder load profile during active illumination than the BMS sees at rest, and a new cell in its first ten cycles has slightly higher internal resistance than it will after break-in. Under peak draw, the terminal voltage dips below the BMS cutoff threshold and the device shuts down — even though resting voltage reads normal. This is not a defective cell. Run three to five full charge-discharge cycles and the resistance drops enough that the cutoff no longer triggers under clinical load.

The charge indicator has been sitting at the same point for over an hour and isn't reaching 100% — is the cell accepting a charge?

Yes — the charge IC applies a conservative current limit on a new cell during its first charge cycle, which extends the time to reach termination voltage. The indicator stalls in the upper range because the IC has shifted from bulk charge to trickle, and the percentage display doesn't always track that transition accurately. Leave the device on charge until the indicator confirms full — do not disconnect early. After the first complete charge, subsequent cycles reach 100% at the normal rate.

After the battery sat unused in storage for several months, the device won't power on at all — how do I recover it?

Extended storage causes self-discharge, and if the cell voltage has dropped below roughly 2.5V, the BMS enters a deep-discharge lockout and will not pass current to the device. A standard charger won't recover the cell from this state on its own. Place the cell in a charger with a recovery or wake mode — one that applies a low pre-charge current (typically 0.1C) to bring voltage back above 3.0V before switching to normal charge rate. Once the cell reaches 3.0V, the BMS releases the lockout and charging proceeds normally.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.