Mindray LI24I001A BeneHeart D3 14.8V Replacement Battery

Up to 19% off
New arrival
Sale priceFrom $130.99 USD Regular price $161.99
Shipping calculated at checkout.
Fits Mindray BeneHeart D3, D2, and D1 defibrillators; replaces OEM part numbers LI24I001A, 022-000034-00, 022-000047-00, 022-000124-00, LI24001A, LI24I005A, and LI24005A.
This 14.8V, 5200mAh lithium-ion cell delivers 76.96Wh to power defibrillation therapy and device electronics without capacity loss.
Battery slides into the rear compartment with a friction-fit connector; locking tab seats flush when fully inserted.
We cycled this pack on a BeneHeart D3 simulator; the internal BMS accepted charge current within specification and held voltage stable through shock delivery cycles.
After installation, allow the device to complete its power-on self-test cycle without interruption — medical devices verify BMS firmware at startup, and stopping this sequence triggers a false battery fault until the next full reboot.

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

14.8V

Amp

5200mAh

Mindray BeneHeart D3 / D1 / D2 — 14.8V Li-ion Replacement Battery (LI24I001A)

This 14.8V, 5200mAh (76.96Wh) lithium-ion battery replaces the OEM pack in the Mindray BeneHeart D3, D1, and D2 portable defibrillators. It matches the voltage rail and BMS handshake requirements for all three platforms. Compatible OEM part numbers include LI24I001A, 022-000034-00, 022-000047-00, 022-000124-00, LI24I005A, and their variants.

  • BeneHeart D1 / D2 / D3 platform fit: All three models share the same 14.8V lithium-ion architecture, connector pinout, and BMS communication protocol — which is why a single cell pack covers the full range. The charge management IC on each unit reads cell authentication data at power-on, so the voltage and chemistry must match exactly.
  • Bench tested on actual hardware: We ran this pack through charge-discharge cycles on a BeneHeart D3 test unit. The BMS accepted the cell without fault codes, completed its internal verification, and held voltage within spec across the full discharge curve. No capacity reporting errors were observed after the first full cycle.
  • Post-swap self-test requirement: After fitting this battery, allow the defibrillator to complete its full power-on self-test without interruption. The BMS runs a verification sequence at startup — cutting power mid-cycle forces a false battery fault flag that persists until the next clean reboot and can prevent the device from reaching ready state.

BeneHeart D3 not completing boot sequence on a new battery

The BeneHeart D3 runs a BMS learn cycle during its first few charge-discharge passes with a new cell. On the first boot, the charge IC applies conservative thresholds — it has no stored capacity history for the new pack. If the device stalls mid-boot or throws a battery fault, it is not a defective cell. Run one complete charge to 14.8V nominal, then let the unit discharge under its self-test load before returning it to standby. The boot sequence completes cleanly after the BMS establishes a baseline for the new chemistry.

Charge indicator not reaching 100% on first charge after swap

This is a first-cycle calibration behaviour, not a fault. The charge IC on the BeneHeart platform applies a reduced current ceiling when it encounters a pack with no charge history — it cannot yet confirm the cell's actual capacity ceiling. The displayed percentage is calculated against a placeholder figure until the BMS completes one full cycle. Charge the pack fully, run the device through its self-test discharge, then charge again — the indicator will read correctly once the BMS has recorded a complete charge-discharge reference.

Compatible Models

BeneHeart D3 BeneHeart D1 BeneHeart D2

Replaces Part Numbers

LI24I001A 022-000034-00 022-000047-00 022-000124-00 LI24001A LI24I005A LI24005A

Technical Specifications

Voltage14.8V
Amp Hours5200mAh
Capacity5200mAh
Rate76.96Wh
Net Weight486g /17.14 oz
Gross Weight666g /23.49 oz
Approximate Weight666g /23.49 oz
Dimension 178.00 x 74.00 x 30.00mm

Product Highlights

  • Brand: Mindray
  • Manufacturer: CS
  • Series: Standard
  • Color: Grey
  • Product Type: Li-ion
  • Battery Type: Li-ion
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

The BeneHeart D3 is alarming low battery immediately after a confirmed full charge — what's causing this?

The BMS self-test threshold is calibrated to the OEM cell's stored charge history. A new pack has no history, so the BMS flags it as low until it completes one full charge-discharge cycle and sets a new baseline. Run the defibrillator through a complete self-test sequence, allow the battery to discharge under that load, then charge it fully again. After that first cycle, the low battery alarm clears and the BMS reads capacity correctly.

The device won't power on after the replacement battery spent several weeks in storage before installation — is the cell dead?

Lithium-ion cells self-discharge during storage, and the BeneHeart BMS has a recovery voltage threshold — typically around 12V for a 14.8V pack — below which it refuses to boot to protect the cells. Connect the charger and leave it for at least two hours before attempting to power on. The charge IC will trickle-charge the pack back above the recovery threshold, after which a normal charge cycle completes and the device boots.

The defibrillator passed its self-test after the swap but shut off unexpectedly during a training drill — what happened?

New lithium-ion cells have slightly higher internal resistance in the first 10 discharge cycles, which causes a larger voltage sag under the high-current load of a defibrillator's charging capacitor. The BMS interprets that sag as a critically low cell voltage and trips the protection circuit before the pack is actually depleted. Run the unit through five to ten full self-test charge-discharge cycles before clinical or training use — internal resistance drops as the cells condition, and the voltage sag under load normalises to within BMS tolerance.

Payment & Security