Archos 40C Titanium AC40CTI Replacement Battery 3.7V 1200mAh
This product ships directly from our Manufacturer's Warehouse and is usually delivered within 7 – 10 business days to your doorstep.
WECARE5
Check that your old battery model number and device model to match our description. This makes sure they work together.
We ship your order same day if you buy it before 4 PM EST.
Archos 40C Titanium AC40CTI Replacement Battery 3.7V 1200mAh - is backordered and will ship as soon as it is back in stock.
Let customers speak for us
Send Your Battery Photo
Expert Technician Help
Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.
POST YOUR BATTERY IMAGE
Product & Solutions Expert
✉ sales@batteryweb.com
Battery Care Tips
Battery Care Tips
🔹 Getting Started
Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.
🔹 Keep It Healthy
Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.
Delivery and Shipping
Delivery and Shipping
🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.
Disclaimer
Disclaimer
⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.
🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.
Archos 40C Titanium AC40CTI Replacement Battery 3.7V 1200mAh - is backordered and will ship as soon as it is back in stock.
Voltage
3.7V
Amp
1200mAh
Archos 40C Titanium — 3.7V Li-ion Replacement Battery (AC40CTI)
This is a 3.7V, 1200mAh Li-ion cell for the Archos 40C Titanium smartphone. It replaces part number AC40CTI directly. The 40C Titanium uses a compact form factor at 55.64 × 47.85 × 4.62mm — verify physical dimensions before fitting.
- 40C Titanium platform fit: The AC40CTI cell sits on a single-cell 3.7V rail with a passive protection circuit module. The connector pinout and PCM layout match the original board contacts, so no rewiring is needed on reassembly.
- Bench tested on actual hardware: We cycled this cell through charge and discharge on the 40C Titanium platform. The PCM held cutoff at the correct thresholds and the fuel gauge IC accepted the new cell without tripping a fault state.
- Fuel gauge recalibration on first use: After fitting, run one complete discharge to shutdown followed by a full charge before enabling any fast-charge mode. The 40C Titanium's fuel gauge IC was calibrated to the worn discharge curve of the original cell — one full cycle corrects the reference so percentage readings track accurately.
Sudden shutdown at 20–30% on the Archos 40C Titanium after a cell swap
A new cell has a steeper voltage discharge curve than a degraded one. The fuel gauge IC on the 40C Titanium still references the old curve, so it reads 25% when the actual cell voltage has already dropped close to the PCM cutoff threshold under screen or audio load. When current draw spikes, voltage collapses past the cutoff and the device shuts down instantly. Run one full discharge-to-shutdown cycle and a complete charge to let the coulomb counter re-anchor to the new cell's actual curve — shutdowns at false percentages stop after that cycle.
Archos 40C Titanium not powering on after storage
Li-ion cells in storage self-discharge over weeks. If the cell voltage drops below approximately 2.5V, the PCM enters lockout mode to prevent damage — the device shows nothing when you press power. Plug into a wall charger rather than a PC port, since a PC port may not source enough current to wake a locked-out PCM. Hold on the charger for at least 15–20 minutes before attempting to power on; once the cell climbs above 3.0V, the PCM releases and normal charging resumes.
Compatible Models
Replaces Part Numbers
Technical Specifications
Product Highlights
- Brand: Archos
- Manufacturer: CS
- Series: Standard
- Color: Black
- Product Type: Li-ion
- Battery Type: Li-ion
- Warranty: 12 Months
- Bulk Orders: sales@batteryweb.com
Frequently Asked Questions
Why does my Archos 40C Titanium shut off suddenly when the battery still shows 20% or more?
The fuel gauge IC on the 40C Titanium was calibrated to the discharge curve of the original worn cell. A new cell has a steeper voltage drop under load, so the reported percentage is higher than the actual usable charge remaining. When screen brightness or audio playback spikes current draw, the cell voltage collapses past the PCM cutoff before the gauge catches up. Run one full discharge to automatic shutdown followed by a complete charge — the coulomb counter resets to the new cell's curve and the shutdowns stop.
The Archos 40C Titanium battery percentage jumps around erratically after I fitted the new cell — is something wrong?
Nothing is wrong with the cell. The fuel gauge IC stores a reference model of the old cell's internal resistance and capacity fade — the new cell measures differently, so the IC overestimates or underestimates state of charge until it recalibrates. Percentage jumping by 5–15 points between readings is normal in the first two cycles. Complete two full discharge-charge cycles without interruption and the IC builds an accurate model of the new cell; readings stabilise after that.
My Archos 40C Titanium gets warm near the battery area during the first few charges after replacing the cell — is that normal?
Yes, and it is specific to the first few cycles. A new cell has higher internal impedance than a broken-in one. The charge IC pushes current into that higher impedance, which dissipates more energy as heat during the constant-current phase. Warmth — not heat — in that area during charging is expected for the first two or three cycles as the cell's impedance settles. If the device becomes hot to the touch or charging stops early, disconnect and let it cool to room temperature, then resume charging at a lower ambient temperature.