Replaces AB1600EWML battery in Philips Xenium E350 flip phone models.
3.7V Li-ion cell at 1500mAh capacity restores talk time on aged packs.
Connector seats into Xenium E350 battery slot with spring-loaded contact alignment.
Bench testing showed BMS accepted full 3.7V charge cycle without fault codes.
On first insertion, allow one complete discharge-charge cycle before resuming normal use—the fuel gauge IC needs to recalibrate against this cell's discharge curve.

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

3.7V

Amp

1500mAh

Philips Xenium E350 — 3.7V Li-ion Replacement Battery (AB1600EWML)

This is a 3.7V Li-ion replacement battery rated at 1500mAh (5.55Wh) for the Philips Xenium E350 flip phone. It replaces OEM part AB1600EWML and fits directly into the E350's battery compartment. Install it when the original cell no longer holds a useful charge between uses.

  • Xenium E350 fit: The E350 uses a dedicated single-cell Li-ion pack with a specific connector keyed to AB1600EWML. This replacement matches that connector, voltage rail, and BMS communication pins — no modifications needed.
  • Bench tested on actual hardware: We cycled this cell through charge and discharge on the E350 platform. The BMS accepted charge without triggering protection cutoffs, and the fuel gauge IC registered the cell correctly after a full conditioning cycle.
  • Fuel gauge recalibration after swap: After installing this battery, run one complete discharge-to-charge cycle before enabling any fast charge mode. This lets the E350's coulomb counter recalibrate against the new cell's discharge curve, reducing percentage-reporting errors on early cycles.

Sudden shutdown at 20–30% on the Xenium E350

The E350's modem radio draws a sharp current spike during active calls. If the replacement cell has higher internal impedance than the original, voltage sags below the BMS cutoff threshold under that load — even when the fuel gauge still shows charge remaining. This is a voltage-cliff failure, not a capacity failure. The fix is to complete two or three full discharge cycles so the BMS can map the cell's actual voltage curve. After conditioning, shutdowns under load at 20–30% should stop.

Phone reports wrong battery percentage after cell swap

The E350's fuel gauge IC stores a learned discharge curve from the original cell. A new cell with a different impedance profile will cause the IC to misread state-of-charge — typically reporting 100% too quickly or dropping percentage in large jumps. This is not a fault with the replacement cell. Run one full uninterrupted discharge until the phone shuts down, then charge to 100% without interruption. After that single cycle, the coulomb counter recalibrates and percentage reporting stabilises.

Compatible Models

Xenium E350

Replaces Part Numbers

AB1600EWML

Technical Specifications

Voltage3.7V
Amp Hours1500mAh
Capacity1500mAh
Rate5.55Wh
Gross Weight100g /3.53 oz
Approximate Weight100g /3.53 oz

Product Highlights

  • Brand: Philips
  • Manufacturer: CS
  • Series: Standard
  • Color: Black
  • Product Type: Li-ion
  • Battery Type: Li-ion
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

My Philips Xenium E350 powers off suddenly during a call even though it still shows 25% battery — is the new cell faulty?

This is a voltage-sag shutdown, not a capacity defect. During a call, the modem draws a current spike that the new cell — with slightly higher impedance than a worn-in cell — cannot sustain without voltage dropping below the BMS cutoff. Complete three full discharge-charge cycles to condition the cell and let the BMS map the voltage curve. After conditioning, measure open-circuit voltage after a full charge — it should read 4.1–4.2V.

The battery percentage on my E350 jumps around erratically after fitting the replacement — it went from 60% to 15% in minutes.

The fuel gauge IC on the E350 is calibrated to the discharge curve of the original cell. A new cell with a different internal resistance profile throws off the coulomb counter, causing large percentage jumps. Run one complete, uninterrupted discharge until the phone shuts off, then charge fully to 100% without removing the phone from charge early. That single cycle resets the IC's learned curve and stabilises percentage reporting.

My E350 won't power on at all after the replacement battery sat in storage for several months — is it dead?

A Li-ion cell stored for months can self-discharge below 2.5V per cell, which triggers BMS lockout to prevent damage. The phone will not power on from this state because the BMS blocks current until the cell voltage recovers. Connect the phone to a charger and leave it for 20–30 minutes without pressing the power button — the charge IC will trickle current into the cell to bring it above the BMS recovery threshold. Once voltage crosses approximately 3.0V, the BMS re-initialises and normal charging resumes.