Compaq Armada 7400 14.4V Replacement Battery 104724-001
Check that your old battery model number and device model to match our description. This makes sure they work together.
We ship your order same day if you buy it before 4 PM EST.
Compaq Armada 7400 14.4V Replacement Battery 104724-001 - is backordered and will ship as soon as it is back in stock.
Let customers speak for us
Send Your Battery Photo
Expert Technician Help
Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.
POST YOUR BATTERY IMAGE
Product & Solutions Expert
✉ sales@batteryweb.com
Battery Care Tips
Battery Care Tips
🔹 Getting Started
Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.
🔹 Keep It Healthy
Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.
Delivery and Shipping
Delivery and Shipping
🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.
Disclaimer
Disclaimer
⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.
🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.
Compaq Armada 7400 14.4V Replacement Battery 104724-001 - is backordered and will ship as soon as it is back in stock.
Voltage
14.4V
Amp
4400mAh
Compaq Armada 7400 Series — 14.4V Li-ion Replacement Battery (104724-001)
This 14.4V Li-ion battery pack replaces the original power cell in Compaq Armada 7400 series notebooks, including the 6300, 6266, 6433, and 6400 model variants. Capacity is 4400mAh (63.36Wh), matching the OEM specification. It fits the physical bay and connector of the Armada 7400 chassis without modification.
- Armada 7400 series compatibility: All listed Armada 7400 variants share the same 14.4V battery rail, physical form factor, and connector pinout. The BMS handshake uses the same SMBus protocol across the 6266, 6300, 6433, and 6400 sub-models, so one cell SKU covers the full range.
- Bench tested on actual hardware: We ran this cell through charge and discharge cycles on the Armada 7400 platform. The BMS communicated correctly over SMBus, accepted a full charge without thermal cutoff, and reported state-of-charge data to the system without error flags.
- First-cycle calibration for Armada 7400: After installing, let the notebook discharge completely to hibernate cutoff, then charge uninterrupted to 100% without using the machine. This resets the BIOS battery learn cycle and clears the inaccurate health warning that appears after every cell swap on this platform.
BIOS reporting battery health as poor immediately after replacement
The Armada 7400 BIOS reads health data from the battery's EEPROM on first contact. When a new cell arrives, the EEPROM contains factory default values that don't match the laptop's learned discharge profile, so the BIOS flags it as degraded. This is not a fault with the replacement cell. Run one full discharge-to-hibernate cycle followed by an uninterrupted charge to 100% — this writes new baseline data to the BIOS battery learn register and clears the warning.
Armada 7400 shutting down at 20–30% charge shown on screen
This happens when the fuel gauge IC has not yet calibrated against the new cell's actual discharge curve. The gauge overestimates remaining charge, and when real cell voltage drops under combined CPU and display load, the pack hits its BMS cutoff voltage before the OS expects it. The fix is two to three full discharge and recharge cycles, which allow the fuel gauge IC to map the new cell's voltage-to-capacity curve accurately. After calibration, the shutdown threshold should align with 0–5% displayed charge at approximately 10.8V under load.
Compatible Models
Replaces Part Numbers
Technical Specifications
Product Highlights
- Brand: Compaq
- Manufacturer: CS
- Series: Standard
- Color: Black
- Product Type: Li-ion
- Battery Type: Li-ion
- Warranty: 12 Months
- Bulk Orders: sales@batteryweb.com
Frequently Asked Questions
My Armada 7400 shows 0% battery or "unknown" in Windows right after I put the new battery in — is it dead?
It isn't dead. The fuel gauge IC in the Armada 7400 hasn't calibrated against the new cell yet, so it reads 0% or reports an unknown state. Run a full discharge to hibernate cutoff, then charge uninterrupted to 100% without powering the machine on mid-cycle. After one or two complete cycles the gauge IC maps the new cell's voltage curve and the readout stabilises.
Windows shows the Armada 7400 battery as 63Wh but BIOS is reporting a different Wh figure — which is right?
The BIOS pulls its Wh figure from the battery EEPROM's rated-capacity register, which may reflect the previous cell's stored value or a factory default that doesn't match the replacement chemistry. The actual cell in this SKU is 63.36Wh at 14.4V and 4400mAh — that is the correct figure. Run the BIOS battery learn cycle (full discharge to hibernate, then full uninterrupted charge) and the EEPROM register will update to reflect the new cell's actual capacity.
The Armada 7400 charges fine but the battery gauge jumps around wildly for the first few days — what's causing that?
The fuel gauge IC uses historical discharge data to predict remaining charge, and after a cell swap that historical data belongs to the old, degraded cell. Until the IC collects two to three full cycles against the new cell, it interpolates incorrectly and the percentage reading swings erratically. No fix is needed beyond completing those calibration cycles. By the third full discharge-and-recharge cycle the gauge should track steadily from 100% down to the hibernate cutoff at roughly 10.8V.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Related Products
Engineered for Performance. Built to Last.
Check out our top-rated selection of reliable products built to last. We offer high-quality options that deliver consistent performance for all your needs.