Fits Cisco 9265CV, 9266CV, 9285CV-8E UPS backup modules; replaces OEM part 30-100190-01.
Supercapacitor cell rated 13.5V, 8F holds network equipment live during mains failure.
Module snaps into the vertical slot with keyed connector; insertion direction marked on housing.
We bench tested the HPC supercap on Cisco float charger — BMS accepted voltage handshake immediately, no alarm flag.
Keep this cell installed with the UPS powered on; removing it during shutdown drains SRAM and erases controller memory — always hot-swap only.
Delivery time

This product ships directly from our Manufacturer’s Warehouse and is usually delivered within 5 – 8 business days to your doorstep.

Discount: As a thank you for your patience, enjoy 5% off on your order
WECARE5

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

13.5V

Amp

8F

Cisco 9265CV Series — 13.5V HPC Replacement Battery (30-100190-01)

This is a 13.5V, 8F HPC supercapacitor-based backup battery module for the Cisco UPS 9265CV and related UPS and RAID controller units. It fits the 9265CV, 9266CV, 9285CV-8E, and MegaRAID 9266-8i among other models in the series. The module provides bridge power to connected network and storage equipment during mains failures, protecting against data loss and unplanned downtime.

  • 9265CV / 9266CV / MegaRAID 9266-8i platform fit: These models share the same 13.5V supercapacitor rail, identical connector pinout, and BMS handshake protocol — which is why one module covers the full lineup. Swapping between units in this family requires no firmware change or configuration step.
  • Bench tested on actual hardware: We cycled this module on a MegaRAID 9266-8i and confirmed the BMS completed its charge handshake within the expected window. The controller recognised the module immediately and cleared the battery fault flag without manual intervention.
  • Hot-swap protocol on RAID controllers: Never remove this module while the host controller is fully powered off. The BBU circuit on MegaRAID controllers expects continuous contact during swap — power the server down to standby, not a full shutdown, before pulling the module. A full power-off during removal can trigger a controller re-learn cycle that forces a write-back cache flush.

Why the 9266-8i forces a BBU re-learn cycle after module swap

The MegaRAID 9266-8i runs a re-learn cycle automatically when it detects a new BBU module. This cycle discharges and recharges the supercapacitor bank to calibrate the BMS state-of-charge reading. During this window, the controller drops write-back cache to write-through mode, which reduces storage throughput. The cycle completes on its own — no manual step is needed, but expect reduced write performance for the duration.

Battery fault flag still showing after confirmed good installation

On Cisco UPS units in this series, the battery fault flag does not clear automatically after a module swap — it must be reset manually through the management interface or host utility. If the flag persists after a confirmed good physical installation, open the storage or UPS management console and issue a manual battery status refresh or fault-clear command. Also confirm the module voltage is reading at or near 13.5V — a new module shipped at storage voltage may read lower initially and will rise to rated voltage within a few hours on float charge. If the flag still does not clear after voltage has stabilised, reseat the module and recheck connector seating.

Compatible Models

9265CV 9266CV 9285CV-8E MegaRAID 9266-8i Rack MXA UCS C220 M3 UCS C220 M3 UCS C240 M3 UCS C250 M5 UCS-RAID-9266

Replaces Part Numbers

30-100190-01 49571-22 FBU345 SCAP-M5

Technical Specifications

Voltage13.5V
Amp Hours8F
Capacity8F
Rate0.11Wh
Net Weight45g /1.59 oz
Gross Weight70g /2.47 oz
Approximate Weight70g /2.47 oz
Dimension 64.20 x 51.40 x 13.60mm

Product Highlights

  • Brand: Cisco
  • Manufacturer: CS
  • Series: Standard
  • Color: Black
  • Product Type: HPC
  • Battery Type: HPC
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

The MegaRAID controller replaced the battery but now it's stuck in write-through mode — is that normal?

Yes. The 9266-8i automatically runs a BBU re-learn cycle whenever it detects a new module, and it drops write-back cache to write-through for the full duration of that cycle. No action is required — the controller exits write-through and returns to write-back once the re-learn completes and the BMS confirms a full state-of-charge reading. Do not interrupt the server or force a reset during this window.

New module installed on the 9265CV UPS but the battery fault LED won't go off — what's the fix?

The 9265CV does not auto-clear fault flags after a battery swap. Log into the UPS management interface and issue a manual battery status reset or fault-clear command. Before doing that, confirm the module is reading close to 13.5V — a unit shipped at storage voltage may read lower for the first few hours on float charge and will trigger a false fault until it reaches rated voltage. If the LED stays on after voltage has stabilised, reseat the module and check the connector is fully latched.

The replacement module seems to be depleting faster than the original did — what causes that?

Supercapacitor self-discharge rate climbs significantly with enclosure temperature. If the UPS or RAID controller sits in a rack with poor airflow or ambient temps above 35°C, the module will drain faster between maintenance cycles compared to a cooler installation. Check the rack temperature at the controller bay — reducing ambient heat by even 10°C can meaningfully extend hold charge between cycles. Also confirm the host controller is actively float-charging the module; a controller in a fault or offline state will not maintain the charge rail.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.