Itron Corus A111472 Compatible Battery 3.6V 19000mAh
This product ships directly from our Manufacturer’s Warehouse and is usually delivered within 5 – 8 business days to your doorstep.
WECARE5
Check that your old battery model number and device model to match our description. This makes sure they work together.
We ship your order same day if you buy it before 4 PM EST.
Itron Corus A111472 Compatible Battery 3.6V 19000mAh - is backordered and will ship as soon as it is back in stock.
Let customers speak for us
Send Your Battery Photo
Expert Technician Help
Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.
POST YOUR BATTERY IMAGE
Product & Solutions Expert
✉ sales@batteryweb.com
Battery Care Tips
Battery Care Tips
🔹 Getting Started
Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.
🔹 Keep It Healthy
Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.
Delivery and Shipping
Delivery and Shipping
🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.
Disclaimer
Disclaimer
⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.
🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.
Itron Corus A111472 Compatible Battery 3.6V 19000mAh - is backordered and will ship as soon as it is back in stock.
Voltage
3.6V
Amp
19000mAh
Itron Corus Gas Volume Converter — 3.6V Li-MnO2 Replacement Battery (A111472)
This 3.6V lithium-manganese dioxide battery replaces the OEM A111472 pack in the Itron Corus Gas Volume Converter. It carries 19000mAh (68.4Wh) of capacity — enough for extended field survey sessions without a mid-day swap. Li-MnO2 chemistry is standard in this instrument class because it holds a flat discharge curve across the temperature ranges common in field utility work.
- Gas Volume Converter compatibility: The A111472 form factor matches the Itron Corus converter's battery bay exactly — same connector pinout, same voltage rail, same BMS handshake protocol. Swapping to a mismatched cell voltage will cause the converter to log fault events and suspend measurements.
- Bench tested on actual hardware: We cycled this pack under sustained sensor-load current draw, monitoring the BMS cutoff thresholds. The pack held voltage within spec through repeated logging intervals without triggering a false low-battery event.
- First-use calibration on the Itron Corus converter: After fitting this battery, run a full calibration cycle through the instrument menu before field deployment. The converter maps battery state during that cycle — skipping it causes premature low-battery warnings to appear during your first measurement session, even with a fully charged pack.
Voltage dropout during sustained gas volume logging
The Itron Corus converter draws a steady current across its sensor and data-logging circuits during active measurement sessions. If the cell cannot sustain that load without a voltage dip, the instrument's internal threshold will interpret it as a depleted battery and halt logging. Li-MnO2 chemistry handles this better than alkaline alternatives because the discharge curve stays flat well into the usable capacity range. A cell showing resting voltage below 3.4V under no load has likely already dropped below the converter's operating threshold and should be replaced before field deployment.
Converter will not recognise a new pack after months in storage
Li-MnO2 cells self-discharge slowly during storage, and if a pack sits long enough, the BMS can enter a sleep state below its recovery voltage threshold. The Itron Corus converter may show a blank battery indicator or refuse to power on, even with a new pack installed. Connect the instrument to its charger and hold the charge connection for at least 15 minutes — this gives the BMS enough trickle current to exit sleep mode and re-initialise. If the instrument still does not respond, verify the pack's resting voltage reads at or above 3.2V before concluding the pack is faulty.
Compatible Models
Replaces Part Numbers
Technical Specifications
Product Highlights
- Brand: Itron Corus
- Manufacturer: CS
- Series: Standard
- Color: Black
- Product Type: Li-MnO2
- Battery Type: Li-MnO2
- Warranty: 12 Months
- Bulk Orders: sales@batteryweb.com
Frequently Asked Questions
My Itron Corus converter shuts off mid-logging session even though the battery indicator looked fine at the start — what's causing it?
The converter's battery indicator reads resting voltage, not load voltage. Under sustained sensor and logging current draw, a partially discharged Li-MnO2 cell can sag below the instrument's operating threshold even if the resting voltage looked acceptable. This triggers an abrupt shutdown to protect the measurement circuit rather than logging corrupted data. Before your next session, check that the pack's resting voltage sits at or above 3.5V — anything lower will drop out under field load.
The converter powers on normally but resets or drops readings partway through a USB data transfer to a PC — is this a battery issue?
Yes. USB data transfer adds a combined current draw on top of the active sensor load — the converter is powering its comms circuit, sensor module, and display simultaneously. If the cell voltage sags under that combined draw, the instrument resets to protect data integrity. This is common when a pack has partial capacity remaining but not enough headroom for the combined load spike. Charge the battery fully before any transfer session and confirm resting voltage is at or above 3.5V before connecting the USB cable.
After the Itron Corus converter sat unused in its carry case for several months, it now shows an inconsistent battery percentage that jumps around at reboot — why?
The converter's voltage-threshold indicator calibrates to the cell it last used. After extended storage, the new or rested cell has a slightly different open-circuit voltage profile, so the display misreads state-of-charge until the instrument re-maps to the new cell. Run one full calibration cycle through the instrument menu immediately after fitting the pack. The percentage display will stabilise after calibration completes and the instrument has logged the new cell's voltage curve.