Fits Nova 5000 classroom data logger, replaces OEM part Nova4AH battery pack.
6V, 2000mAh Ni-MH chemistry powers continuous sensor operation during extended field surveys without cutoff.
Connector slides straight into battery slot with positive terminal facing the spring contact inside.
We bench-tested this pack on the Nova 5000 probe initialization cycle — BMS held steady through repeated sensor power-ups with no premature dropout.
After installation, run a full calibration cycle through the instrument menu before field deployment — the logger maps battery voltage during calibration, and skipping this step causes premature low-battery warnings on the first measurement session.
Delivery time

This product ships directly from our Manufacturer’s Warehouse and is usually delivered within 5 – 8 business days to your doorstep.

Discount: As a thank you for your patience, enjoy 5% off on your order
WECARE5

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

6V

Amp

2000mAh

Nova 5000 Classroom Data Logger — 6V Ni-MH Replacement Battery (Nova4AH)

This is a 6V, 2000mAh Ni-MH replacement battery for the Nova 5000 classroom data logger. It uses OEM part number Nova4AH and fits the 5000 series directly. The Nova 5000 collects environmental and scientific measurements, and this pack keeps it running through extended classroom experiments and field surveys.

  • Nova 5000 compatibility: The 5000 series uses a 6V Ni-MH pack with a specific connector and BMS handshake. This replacement matches that voltage rail and connector pinout, so the logger recognises the pack and reports charge state correctly from the first boot.
  • Bench tested on actual hardware: We ran this pack through sensor initialisation cycles and sustained logging loads on the bench. The BMS handled the current spike at probe power-up without tripping, and voltage held stable under continuous multi-sensor draw.
  • First-use calibration step: After installing this pack, run a full calibration cycle through the Nova 5000 instrument menu before field deployment. The logger maps battery state during calibration — skipping this step causes premature low-battery warnings on the first measurement session, even with a fully charged pack.

BMS lockout after the Nova 5000 sat unused in a carry case for months

Ni-MH cells self-discharge during storage. If a pack sits unused long enough, cell voltage drops below the BMS recovery threshold and the pack enters a protection state. At that point, the logger either shows no charge or refuses to power on, even after placing it on charge. To recover the pack, connect it to the charger and leave it for a full charge cycle — most BMS circuits re-initialise once voltage climbs back above 5.4V.

Nova 5000 shuts down mid-logging session with no low-battery warning

This happens when sustained sensor load pulls voltage down faster than the logger's threshold indicator tracks. The display shows adequate charge, then the unit cuts out without warning. The cause is voltage sag under continuous multi-sensor draw — the pack voltage dips below the cutoff threshold before the indicator catches up. If this occurs, let the pack rest for two minutes and check open-circuit voltage: a healthy cell should read above 5.8V at rest.

Compatible Models

5000 classroom data logger

Replaces Part Numbers

Nova4AH

Technical Specifications

Voltage6V
Amp Hours2000mAh
Capacity2000mAh
Rate12Wh
Net Weight278.3g /9.82 oz
Gross Weight328.3g /11.58 oz
Approximate Weight328.3g /11.58 oz
Dimension 99.80 x 72.22 x 14.79mm

Product Highlights

  • Brand: Nova
  • Manufacturer: CS
  • Series: Standard
  • Color: Green
  • Product Type: Ni-MH
  • Battery Type: Ni-MH
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

The Nova 5000 powers on fine but shuts off every time I start a USB transfer to the PC — is this the battery?

Yes, this is a known combined-draw issue. USB data transfer adds load on top of active sensor modules, and the total current draw can push a degraded or partially charged Ni-MH pack below the cutoff voltage. The logger shuts off to protect the BMS. Charge the pack fully, confirm open-circuit voltage reads above 5.8V before connecting USB, then retry the transfer.

New pack installed, but the Nova 5000 is showing a low-battery warning after just a few minutes of logging — what's wrong?

The logger maps battery state during its calibration routine, and if you skip that step after fitting a new pack, it reads from an incomplete baseline and throws early low-battery warnings. Go into the instrument menu and run a full calibration cycle with the new pack installed. After calibration completes, the warning should clear and charge reporting will reflect the actual cell state.

The Nova 5000 won't take a charge after sitting in storage for a school term — is the pack dead?

Not necessarily. Ni-MH cells self-discharge over time, and after several months unused, the pack voltage can drop low enough that the BMS enters a lockout state and blocks the charge circuit. Connect the charger and leave it for a complete uninterrupted charge cycle — the BMS typically re-initialises once cell voltage recovers above 5.4V. If the pack still shows no charge uptake after a full cycle, measure the pack voltage directly; below 4.8V with no rise after charging indicates a cell that will not recover.