Triplett 8060 CamView Elite Replacement Battery 3.7V 5000mAh
This product ships directly from our Manufacturer’s Warehouse and is usually delivered within 5 – 8 business days to your doorstep.
WECARE5
Check that your old battery model number and device model to match our description. This makes sure they work together.
We ship your order same day if you buy it before 4 PM EST.
Triplett 8060 CamView Elite Replacement Battery 3.7V 5000mAh - is backordered and will ship as soon as it is back in stock.
Let customers speak for us
Send Your Battery Photo
Expert Technician Help
Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.
POST YOUR BATTERY IMAGE
Product & Solutions Expert
✉ sales@batteryweb.com
Battery Care Tips
Battery Care Tips
🔹 Getting Started
Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.
🔹 Keep It Healthy
Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.
Delivery and Shipping
Delivery and Shipping
🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.
Disclaimer
Disclaimer
⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.
🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.
Triplett 8060 CamView Elite Replacement Battery 3.7V 5000mAh - is backordered and will ship as soon as it is back in stock.
Voltage
3.7V
Amp
5000mAh
Triplett 8060 CamView Elite Video Test Monitor — 3.7V Li-Polymer Replacement Battery (PT903759)
This 3.7V, 5000mAh Li-Polymer battery replaces the original pack in the Triplett 8060 CamView Elite Video Test Monitor. It fits the monitor's internal bay using the OEM form factor — 62.00 x 35.80 x 18.40mm. Voltage and cell chemistry match the original specification exactly.
- CamView Elite platform fit: The 8060 runs its display, video signal processing, and probe power rail from a single Li-Polymer cell. Any replacement must match the OEM voltage curve precisely — a mismatched cell causes the BMS to flag a fault before the display even initialises.
- Bench tested on actual hardware: We cycled this pack through display-on and active video signal loads. The BMS held stable across probe power-up current spikes and sustained display draw without tripping into protection mode.
- Calibration cycle after installation: After fitting this pack, run a full calibration sequence through the 8060's instrument menu before taking it to site. The monitor maps battery state during calibration — skipping this step causes the low-battery warning to trigger well before the cell is actually depleted.
BMS lockout after the 8060 sat unused in a carry case for months
Li-Polymer cells self-discharge slowly in storage. If the 8060 sat unused long enough, the pack voltage can drop below the BMS recovery threshold — typically around 2.5V per cell. At that point the BMS enters a locked state and the monitor will not power on even when connected to a charger. A replacement pack arrives at a safe storage voltage, above the lockout threshold, so the monitor will boot immediately on first charge. If your original pack is in lockout, the fix is a replacement — the BMS cannot recover from deep discharge on its own.
8060 shuts down during USB data transfer to PC
USB data transfer adds a second draw on top of active display and video processing — the combined load can push total current above what a degraded cell can sustain at 3.7V. The voltage sags under the combined draw, the BMS reads it as a low-cell condition, and the monitor cuts power mid-transfer. This is a cell capacity problem, not a firmware issue. A fresh 5000mAh pack handles the combined USB and display load without the voltage sag that triggers shutdown. After replacing the pack, confirm the charge is at or above 3.9V before starting a transfer session.
Compatible Models
Replaces Part Numbers
Technical Specifications
Product Highlights
- Brand: Triplett
- Manufacturer: CS
- Series: Standard
- Color: Blue
- Product Type: Li-Polymer
- Battery Type: Li-Polymer
- Warranty: 12 Months
- Bulk Orders: sales@batteryweb.com
Frequently Asked Questions
The 8060 shows a healthy battery percentage, then shuts off without warning during a logging session — what's causing it?
This happens when the cell can no longer hold voltage under sustained sensor and display load, even if the resting charge reads high. The voltage drops sharply under load, the BMS reads it as a cutoff condition, and the monitor kills power before the percentage indicator catches up. It's a cell degradation issue, not a firmware or settings problem. Replace the pack and confirm resting voltage reads at or above 3.9V before your next session.
My 8060 won't respond to the charger after sitting in the van for several months — is the pack dead?
Most likely the cell self-discharged below the BMS recovery threshold, around 2.5V, and the protection circuit is now locked out. In lockout, the BMS blocks charging entirely, so the monitor won't respond no matter how long you leave it on the charger. The original pack cannot recover from this state on its own. Fit a fresh replacement pack — it ships at a safe storage voltage above the lockout threshold, and the monitor will charge normally from the first connection.
After I installed a new pack, the 8060 is throwing low-battery warnings almost immediately even though the battery is fully charged — how do I fix this?
The 8060 maps its battery state thresholds during the calibration cycle in the instrument menu. If you skip calibration after fitting a new pack, the monitor uses the old cell's discharge curve as its reference, which causes it to misread the new cell's voltage and trigger warnings too early. Run a full calibration sequence through the instrument menu before field use. After calibration completes, the percentage indicator and low-battery thresholds will align correctly to the new 5000mAh cell.