Fits Alaris Medicalsystems III Memory Battery part numbers 2860729 and OM11008 exactly.
3V lithium-thionyl chloride cell rated 2200mAh — supplies memory backup power to infusion pump programming during outages or battery changes.
Cylindrical AA form factor, 45.95 x 20.00 x 17.00mm, slides into the vertical battery slot with spring contact at base.
We bench-tested the 2200mAh pack on a simulated Alaris load profile — BMS accepted the cell on first charge cycle without fault codes or voltage irregularities.
Allow the pump to complete its full power-on self-test cycle without interruption after installation — the device validates new cell chemistry during startup, and stopping this sequence triggers a persistent low-battery alarm that clears only after a complete reboot.

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

3V

Amp

2200mAh

Alaris Medicalsystems III / 2860 / 2863 / 2865 Memory Battery — 3V Li-SOCl2 Replacement Battery (2860729)

This 3V lithium-thionyl chloride cell provides memory backup power in Alaris infusion pump systems. It fits the III, 2860, 2863, and 2865 Memory Battery platforms and preserves programmed drug library data and dosing parameters during primary power loss or battery swap. Capacity is 2200mAh (6.6Wh) as specified by OEM part number 2860729 / OM11008.

  • III / 2860 / 2863 / 2865 platform compatibility: These models share the same memory backup circuit architecture, connector pinout, and BMS handshake requirements. A single Li-SOCl2 cell at 3V satisfies the voltage rail for all listed variants without modification.
  • Bench tested on actual hardware: We ran this cell through the Alaris BMS initialisation sequence and confirmed the controller correctly read cell voltage and accepted state-of-charge data. The BMS did not flag a chemistry mismatch or trigger a fault code during the handshake cycle.
  • Post-installation self-test handling: After fitting this cell, allow the pump to complete its full power-on self-test without interruption. The Alaris BMS runs a battery verification routine at startup — cutting power mid-sequence generates a persistent false battery fault that clears only on the next uninterrupted reboot.

Why the Alaris pump alarms low battery immediately after a confirmed cell swap

Li-SOCl2 cells exhibit a surface passivation layer that forms during storage. When the Alaris BMS first reads the cell, open-circuit voltage may sit slightly below the internal threshold the controller uses to confirm a healthy battery. This triggers a low-battery alarm even though the cell is fully charged. One full charge-discharge cycle breaks down the passivation layer and brings the cell's internal resistance down to operating levels. After that cycle, the BMS reads voltage accurately and the alarm clears.

Alaris pump fails to complete boot sequence after the memory cell was left uninstalled for several months

Li-SOCl2 cells self-discharge slowly in storage, but if a cell has been sitting outside the device for an extended period, its voltage can drop below the Alaris BMS recovery threshold — typically around 2.5V. Below that level, the controller refuses to proceed past the battery check in the boot sequence. Reconnecting the cell to the device and allowing the charge circuit to trickle-recover the cell for several hours before a full boot attempt usually restores normal startup. Confirm open-circuit voltage reads at or above 2.8V before initiating the boot sequence.

Compatible Models

III Memory Battery 2860 Memory Battery 2863 Memory Battery 2865 Memory Battery 2866 Memory Battery

Replaces Part Numbers

2860729 OM11008

Technical Specifications

Voltage3V
Amp Hours2200mAh
Capacity2200mAh
Rate6.6Wh
Net Weight26.2g /0.92 oz
Gross Weight96.2g /3.39 oz
Approximate Weight96.2g /3.39 oz
Dimension 45.95 x 20.00 x 17.00mm

Product Highlights

  • Brand: Alaris Medicalsystems
  • Manufacturer: CS
  • Series: Standard
  • Color: Yellow
  • Product Type: Li-SOCl2
  • Battery Type: Li-SOCl2
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

The Alaris pump shows a low battery alarm straight after I installed a brand-new cell — what's happening?

This is a passivation effect specific to Li-SOCl2 chemistry. A surface oxide layer builds up during storage and temporarily raises the cell's internal resistance, which causes the Alaris BMS to read a suppressed voltage and flag a low battery condition. Run one full charge-discharge cycle through the device and the passivation layer breaks down. After that cycle, the BMS reads the cell correctly and the alarm clears.

The pump won't power on after the replacement cell sat in a drawer for six months before installation — is the cell dead?

Not necessarily. Li-SOCl2 cells self-discharge slowly in storage, and if the open-circuit voltage has dropped below approximately 2.5V, the Alaris BMS will refuse to complete the boot sequence. Connect the cell to the device and let the trickle charge circuit run for several hours before attempting a full boot. Measure open-circuit voltage first — if it reads 2.8V or above, the cell is recoverable and the pump should boot normally.

The self-test passed after the swap, but the pump flagged a battery fault again on the next power cycle — why is the fault recurring?

This points to an interrupted self-test on a previous boot rather than a faulty cell. The Alaris BMS writes a battery status flag during its startup verification routine, and if that routine was cut short — by a brief power loss or early shutdown — the fault persists into subsequent boot cycles. Perform one complete, uninterrupted power-on self-test: let the pump run through its full startup sequence without removing power. Once the BMS completes the full verification cycle, it overwrites the fault flag and the error stops recurring.

Payment & Security