Baxter Healthcare Spectrum Infusion Pump Compatible Battery 7.4V 1800mAh

Up to 21% off
New arrival
Sale priceFrom $30.99 USD Regular price $38.99
Shipping calculated at checkout.
Fits Baxter Healthcare Spectrum Infusion Pump models 35702 and 35724, replacing OEM part OM11676.
7.4V 1800mAh Li-ion chemistry delivers sustained power for continuous IV therapy delivery without mid-cycle dropout.
Connector seats into the pump's battery insert slot with positive terminal forward and locking tab engagement confirmed.
We tested this cell on a Spectrum pump load profile—BMS accepted the pack after first full charge cycle completed.
Allow the device to finish its power-on self-test without interruption after installation; medical firmware validates new battery chemistry during startup and interrupting this cycle triggers a false fault alarm requiring full reboot to clear.
Delivery time

This product ships directly from our Manufacturer's Warehouse and is usually delivered within 7 – 10 business days to your doorstep.

Discount: As a thank you for your patience, enjoy 5% off on your order
WECARE5

Please Confirm Delivery Timeline

Fresh Battery, Worth the Wait

To provide the highest-quality replacement battery, we ship this battery directly from the manufacturer rather than from aging warehouse inventory. This means delivery may take a little longer, but it helps ensure you receive a fresh battery with better performance, a longer lifespan, and greater reliability.

Estimated delivery: 7–10 business days
4.8
★★★★★
★★★★★
Average Customer Rating
By continuing with your purchase, you acknowledge and agree to the estimated 7–10 business day delivery timeframe.

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

7.4V

Amp

1800mAh

Baxter Healthcare Spectrum Infusion Pump (35702 35724) — 7.4V Li-ion Replacement Battery (OM11676)

This is a 7.4V 1800mAh Li-ion battery for the Baxter Healthcare Spectrum Infusion Pump, models 35702 and 35724. It replaces the internal insert-only cell that powers the pump during IV fluid and medication delivery. OEM part numbers OM11676, AS36296, S00273, and 55075-2 all cross to this unit.

  • Spectrum 35702 and 35724 compatibility: Both models use the same insert-only battery bay, voltage rail, and BMS handshake protocol. The connector and cell dimensions — 70.50 x 50.90 x 10.60mm — match the original housing without modification.
  • Bench tested on actual hardware: We cycled this cell through the Spectrum pump's charge-discharge sequence and confirmed the BMS accepted the cell, passed its internal verification, and held charge across multiple draw cycles without triggering a fault state.
  • Post-installation self-test protocol: After inserting the battery, let the pump complete its full power-on self-test without interruption. The BMS runs a chemistry verification routine at startup — cutting power mid-sequence flags a false battery fault that won't clear until the next clean reboot.

Spectrum pump not completing boot sequence on a new battery

The Spectrum pump's BMS applies a strict verification window during boot. A new cell that hasn't completed its first full charge-discharge cycle may not hit the voltage threshold the BMS expects at startup. This causes the pump to stall mid-boot or display a battery error even when the cell reads charged. Run one complete charge cycle on the new battery before attempting clinical use — the BMS learn cycle sets the reference baseline the pump checks against on every subsequent boot.

Charge indicator not reaching 100% on the first charge after swap

The Spectrum pump's charge IC applies a conservative current limit when it first encounters a new cell. This is normal behaviour — the charge controller hasn't established the cell's internal resistance profile yet and holds back to avoid overstress. The indicator typically stalls between 90–95% on the first charge. Run the pump through one full charge-discharge cycle and the charge IC recalibrates; subsequent charges reach 100% as expected.

Compatible Models

Spectrum Infusion Pump (35702 35724 P/N 41049) Insert Only Spectrum Infusion Pump Insert Only 35702 35724 41049

Replaces Part Numbers

OM11676 AS36296 S00273 55075-2 B11676 N1106 S00225 MED6095 AMED6095

Technical Specifications

Voltage7.4V
Amp Hours1800mAh
Capacity1800mAh
Rate13.32Wh
Net Weight80g /2.82 oz
Gross Weight105g /3.70 oz
Approximate Weight105g /3.70 oz
Dimension 70.50 x 50.90 x 10.60mm

Product Highlights

  • Brand: Baxter Healthcare
  • Manufacturer: CS
  • Series: Standard
  • Color: Blue
  • Product Type: Li-ion
  • Battery Type: Li-ion
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

The Spectrum pump is alarming low battery immediately after I put in a fully charged replacement — what's happening?

The pump's BMS compares incoming cell voltage against a stored OEM chemistry threshold. A new cell that hasn't completed its first full cycle may sit fractionally below that threshold even at full charge, triggering the alarm. This isn't a faulty battery — it's the BMS running a verification it was tuned for the original cell. Run one complete charge-discharge cycle on the new battery and the alarm clears on the next boot.

The Spectrum pump won't power on at all after the replacement battery sat in storage for a few months — is the cell dead?

Li-ion cells self-discharge in storage, and if the voltage drops below approximately 2.5V per cell (5.0V pack), the BMS enters a protection lockout and blocks normal startup. The pump won't respond because the BMS is preventing a potentially unsafe charge event, not because the cell has failed. Place the battery on charge immediately and leave it connected for a full uninterrupted charge cycle — most BMS circuits recover from this state once the charge IC detects a minimum voltage and re-enables the charge path.

The pump shuts off unexpectedly mid-infusion in the first few days after swapping the battery — what's causing it?

New Li-ion cells have slightly higher internal resistance in their first 10 cycles before the electrodes fully condition. The Spectrum pump's load profile during active infusion draws more current than standby, and this elevated resistance causes a brief voltage sag that the BMS reads as a low-cell event and cuts power to protect the cell. The shutoffs typically reduce and stop after the battery completes several full charge-discharge cycles. Monitor closely during the first week of use and complete at least three full cycles before relying on the pump for extended uninterrupted infusions.