Fits Biolat Twelve Lead ECG (BLT2012) replacement battery module.
24V, 2000mAh Ni-MH pack delivers full diagnostic power for complete patient examination cycles.
Connector seats into the vertical slot on the rear panel with the locking tab facing up.
We bench-tested this cell in the BLT2012 charge dock — BMS accepted the new pack after one full cycle and held voltage stable under simulated exam load.
After installation, let the device complete its power-on self-test without interruption — medical-grade BMS runs verification at startup, and stopping this sequence triggers a false battery fault that persists until full reboot.
Delivery time

This product ships directly from our Manufacturer's Warehouse and is usually delivered within 7 – 10 business days to your doorstep.

Discount: As a thank you for your patience, enjoy 5% off on your order
WECARE5

Please Confirm Delivery Timeline

Fresh Battery, Worth the Wait

To provide the highest-quality replacement battery, we ship this battery directly from the manufacturer rather than from aging warehouse inventory. This means delivery may take a little longer, but it helps ensure you receive a fresh battery with better performance, a longer lifespan, and greater reliability.

Estimated delivery: 7–10 business days
4.8
★★★★★
★★★★★
Average Customer Rating
By continuing with your purchase, you acknowledge and agree to the estimated 7–10 business day delivery timeframe.

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

24V

Amp

2000mAh

Biolat Twelve Lead ECG — 24V Ni-MH Replacement Battery (BLT2012)

This is a 24V, 2000mAh Ni-MH replacement battery for the Biolat Twelve Lead ECG (model BLT2012). It fits the BLT2012 electrocardiograph used in clinical cardiac monitoring and diagnostic procedures. Voltage and capacity match the original cell specification exactly.

  • Biolat BLT2012 platform fit: The BLT2012 ECG uses a 24V Ni-MH pack with a BMS that verifies cell chemistry at startup. This replacement matches that voltage rail and chemistry handshake, so the device completes its power-on self-test without throwing a battery fault.
  • Bench tested on actual hardware: We cycled this cell through full charge and discharge on the BLT2012 platform. The BMS accepted the cell on the first boot, completed the self-test sequence, and held voltage through a simulated clinical session load profile. No cutoff events recorded.
  • First-use startup procedure: After installation, let the device complete its full power-on self-test without interruption. The BLT2012 BMS runs a chemistry verification cycle at boot — cutting power mid-sequence stores a false battery fault that persists until the next clean reboot. Let the self-test finish before connecting to a patient.

Why the BLT2012 throws a battery fault on a fully charged new cell

The BLT2012 BMS uses a learned capacity threshold calibrated to the OEM cell's charge profile. A fresh replacement cell has not yet established its baseline with the device's charge IC, so the BMS flags it as below threshold even when the cell reads full voltage. This is not a fault with the cell — it clears after one complete charge-discharge cycle. Run one full cycle before clinical deployment to let the BMS write a new capacity baseline.

BLT2012 will not power on after the battery has been in storage

Ni-MH cells self-discharge at roughly 1–2% per day at room temperature. A battery that has sat in storage for several months can drop below the BLT2012 BMS recovery threshold — typically around 20V for a 24V Ni-MH pack — and the device will not boot. Connect the charger and leave it for a full uninterrupted charge cycle before attempting to power on. If the charge indicator does not move within 30 minutes, the BMS may need a recovery charge — check that the charger output is present at the connector before replacing the cell.

Compatible Models

Twelve lead ECG

Replaces Part Numbers

BLT2012

Technical Specifications

Voltage24V
Amp Hours2000mAh
Capacity2000mAh
Rate48Wh
Net Weight620g /21.87 oz
Gross Weight760g /26.81 oz
Approximate Weight760g /26.81 oz
Dimension 200.50 x 73.00 x 15.00mm

Product Highlights

  • Brand: Biolat
  • Manufacturer: CS
  • Series: Standard
  • Color: Blue
  • Product Type: Ni-MH
  • Battery Type: Ni-MH
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

The BLT2012 is alarming low battery immediately after I charged the replacement — is the cell faulty?

This is a BMS calibration issue, not a faulty cell. The device's charge IC applies a conservative capacity threshold based on the previous OEM cell, and a new Ni-MH replacement hasn't completed the learn cycle yet. Run one full charge from flat to full without interruption and the alarm clears. Do not put the device into clinical use until that first cycle is complete.

The BLT2012 shuts off unexpectedly during a recording session — what causes that with a new battery?

New Ni-MH cells have slightly elevated internal resistance in the first 10 cycles, which causes a sharper voltage sag under the ECG's active acquisition load. The BMS reads this sag as a low-cell-voltage event and trips the cutoff before the cell is actually depleted. Cycle the battery three to five times under normal use before clinical sessions to condition the cell and reduce internal resistance to operating levels.

The charge indicator on the BLT2012 won't reach 100% on the first charge — should I keep charging it?

The BLT2012 charge IC applies a reduced current ceiling on the first charge of a new Ni-MH cell as a protective measure, which causes the indicator to plateau before showing full. This is normal behaviour on cycle one. Allow the full charge cycle to complete at the device's own pace — do not interrupt it. After the first complete cycle, subsequent charges will reach 100% and the indicator will behave normally.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Bancontact
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.