BP7233-2 BIRDOG USB Plus Replacement Battery 7.2V 3000mAh Ni-MH
Check that your old battery model number and device model to match our description. This makes sure they work together.
We ship your order same day if you buy it before 4 PM EST.
BP7233-2 BIRDOG USB Plus Replacement Battery 7.2V 3000mAh Ni-MH - is backordered and will ship as soon as it is back in stock.
Let customers speak for us
Send Your Battery Photo
Expert Technician Help
Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.
POST YOUR BATTERY IMAGE
Product & Solutions Expert
✉ sales@batteryweb.com
Battery Care Tips
Battery Care Tips
🔹 Getting Started
Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.
🔹 Keep It Healthy
Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.
Delivery and Shipping
Delivery and Shipping
🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.
Disclaimer
Disclaimer
⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.
🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.
BP7233-2 BIRDOG USB Plus Replacement Battery 7.2V 3000mAh Ni-MH - is backordered and will ship as soon as it is back in stock.
Voltage
7.2V
Amp
3000mAh
BIRDOG USB Plus — 7.2V Ni-MH Replacement Battery (BP7233-2)
This is a 7.2V, 3000mAh Ni-MH replacement battery for the BIRDOG USB Plus satellite signal meter. It fits the USB Plus and USB Plus satellite signal meter range used in construction, telecommunications, and utility survey work. Voltage and capacity match the original BP7233-2 specification.
- USB Plus and Plus signal meter compatibility: Both meter variants run the same 7.2V battery rail with the same physical connector and cell format. The BMS handshake is identical across the range, so one pack covers the full lineup without modification.
- Bench tested on actual hardware: We cycled this pack through the USB Plus charge and discharge sequence, confirming the BMS accepted the pack without fault codes and that cell balance held stable across multiple charge cycles.
- Post-install calibration on the USB Plus: After fitting a new pack, run a full calibration cycle through the instrument menu before deploying to the field. The USB Plus maps battery state during calibration — skipping this step causes premature low-battery warnings during your first measurement session, even when the pack is near full charge.
BMS lockout after the USB Plus sat unused in a carry case for months
Ni-MH cells self-discharge at roughly 1–2% per day at room temperature. A pack left inside a case through an off-season can drop below the BMS recovery threshold — typically around 6.0V on a 7.2V Ni-MH pack — and the BMS enters a protection lockout. At that point the charger sees the pack as absent or faulty and refuses to begin a charge cycle. To recover, use a charger with a trickle or recovery mode that applies a low-current pre-charge pulse to bring cell voltage above the re-initialisation threshold before the main charge cycle begins.
USB Plus shuts off the moment the probe or sensor module powers up
Probe and sensor initialisation pulls a short but sharp current spike — enough to cause a momentary voltage sag on a weakened or partially discharged Ni-MH pack. If that sag drops the pack voltage below the BMS undervoltage trip point, the BMS cuts output instantly and the instrument shuts off mid-startup. This is not a device fault. Charge the pack fully before running sensor-intensive sessions, and if the problem persists on a fresh pack, check that the battery contacts inside the meter are clean and making firm contact — any resistance at the contact point amplifies the voltage drop during the spike.
Compatible Models
Replaces Part Numbers
Technical Specifications
Product Highlights
- Brand: BIRDOG
- Manufacturer: CS
- Series: Standard
- Color: Blue
- Product Type: Ni-MH
- Battery Type: Ni-MH
- Warranty: 12 Months
- Bulk Orders: sales@batteryweb.com
Frequently Asked Questions
The USB Plus powers on fine but resets or loses my logged data partway through a measurement session — why?
Sustained sensor load draws continuous current from the pack, and as Ni-MH cells age, their internal resistance rises enough to cause voltage dropout under that steady draw — not at startup, but after several minutes of active use. The instrument interprets that mid-session voltage dip as a low-battery event and resets to protect the log. Fit a fresh pack and confirm it reads above 8.0V at the terminals immediately after a full charge before heading out.
My USB Plus charger shows a solid charge light almost immediately after I put in the new pack — has it actually charged?
A new Ni-MH pack shipped in a partial state of discharge can confuse chargers that rely solely on delta-V detection to determine end-of-charge. If the pack voltage is already sitting in a mid-range band, some chargers misread the plateau and terminate early. Remove the pack, leave it disconnected for two minutes, then re-seat it and restart the charge cycle — this clears the charger's voltage reference and allows a proper full charge to run.
The battery percentage on the USB Plus display jumps around between readings and doesn't match what I charged to — is the pack faulty?
Ni-MH cells have a relatively flat discharge curve, which makes voltage-based percentage estimation less accurate than with other chemistries. A new pack with cells that haven't been conditioned yet will show this behaviour most obviously in the first few cycles. Run two or three full charge-and-use cycles through the instrument, including the calibration step in the instrument menu, and the percentage display will stabilise as the instrument maps the actual voltage profile of the new cells.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Related Products
Engineered for Performance. Built to Last.
Check out our top-rated selection of reliable products built to last. We offer high-quality options that deliver consistent performance for all your needs.