Casper Via V6X Replacement Battery 3.8V 3000mAh
This product ships directly from our Manufacturer's Warehouse and is usually delivered within 7 – 10 business days to your doorstep.
WECARE5
Check that your old battery model number and device model to match our description. This makes sure they work together.
We ship your order same day if you buy it before 4 PM EST.
Casper Via V6X Replacement Battery 3.8V 3000mAh - is backordered and will ship as soon as it is back in stock.
Let customers speak for us
Send Your Battery Photo
Expert Technician Help
Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.
POST YOUR BATTERY IMAGE
Product & Solutions Expert
✉ sales@batteryweb.com
Battery Care Tips
Battery Care Tips
🔹 Getting Started
Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.
🔹 Keep It Healthy
Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.
Delivery and Shipping
Delivery and Shipping
🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.
Disclaimer
Disclaimer
⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.
🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.
Casper Via V6X Replacement Battery 3.8V 3000mAh - is backordered and will ship as soon as it is back in stock.
Voltage
3.8V
Amp
3000mAh
Casper Via V6X — 3.8V Li-Polymer Replacement Battery
This is a 3.8V, 3000mAh (11.4Wh) Li-Polymer cell for the Casper Via V6X smartphone. It fits the Via V6X directly and restores power when the original cell has degraded or no longer holds a usable charge. Dimensions are 86.20 × 66.00 × 4.85mm — confirm these against the original before installation.
- Via V6X platform fit: The Via V6X uses a standard Li-Polymer pouch format at 3.8V nominal. This cell matches the voltage rail, physical footprint, and connector orientation the mainboard expects. No adapter or modification required.
- Bench tested on actual hardware: We ran this cell through charge and discharge cycles on the Via V6X platform. The BMS accepted the cell without tripping protection cutoffs, and the fuel gauge IC began tracking state-of-charge within the first full cycle.
- First-cycle fast charge precaution: On first use after installation, disable fast charging for one complete discharge-charge cycle. This lets the fuel gauge IC recalibrate its coulomb counter against the new cell's actual discharge curve before high-current charging pushes into an uncalibrated state.
Why the Via V6X reports wrong battery percentage after a cell swap
The Via V6X uses a fuel gauge IC that builds its state-of-charge model around the discharge curve of the original cell. When you swap in a new cell, the IC still references the old curve. Percentage readings can appear stuck, jump erratically, or read 100% while the phone is actually at 70–80%. One full discharge-charge cycle — draining to automatic shutdown, then charging uninterrupted to 100% — forces the IC to remap against the new cell's actual capacity curve. After that cycle, percentage accuracy returns to normal.
Sudden shutdown at 20–30% on the replacement cell
This happens when the cell voltage drops sharply under load — called a voltage cliff — faster than the fuel gauge IC predicted. The modem radio, screen, or both draw a current spike the weakened curve estimate didn't account for, and the BMS cuts power to protect the cell before the OS can warn you. It is most common in the first few cycles when the fuel gauge is still uncalibrated. Run one full discharge-charge cycle and the IC will shift its cutoff threshold to match the real cell voltage behaviour, which pushes the shutdown point below 10%.
Compatible Models
Technical Specifications
Product Highlights
- Brand: Casper
- Manufacturer: CS
- Series: X-Longer
- Color: Black
- Product Type: Li-Polymer
- Battery Type: Li-Polymer
- Warranty: 12 Months
- Bulk Orders: sales@batteryweb.com
Frequently Asked Questions
My Casper Via V6X won't turn on after the replacement battery sat in storage — is the cell dead?
Most likely not. Li-Polymer cells self-discharge in storage, and if voltage dropped below roughly 2.5V the BMS enters lockout mode to prevent further drain. Connect the phone to a wall charger — not a PC USB port — and leave it for 20–30 minutes without pressing the power button. The charge IC trickle-charges the cell back above the BMS recovery threshold, after which the phone boots normally. If the screen shows no charge indicator at all after 30 minutes, try a different cable and confirm the charger delivers at least 5V 1A.
Fast charging stopped working after I installed the new battery — was it working before?
Yes, this is expected on the first cycle. The USB-PD or proprietary fast charge handshake depends on the BMS reporting a valid cell state to the charge IC. On a fresh cell with an uncalibrated fuel gauge, the charge IC defaults to standard 5V charging as a safety fallback. Complete one full discharge-charge cycle on standard charging first. After the fuel gauge IC has mapped the new cell's curve, the fast charge negotiation resumes normally on subsequent cycles.
The Via V6X battery percentage is jumping around erratically — sometimes it drops 15% in seconds, then jumps back up.
The fuel gauge IC is recalibrating against the new cell's discharge curve and its coulomb counter is temporarily out of sync with actual cell voltage. This is normal in the first two to three cycles after a cell swap. The fix is one uninterrupted full discharge — let the phone run down to automatic shutdown — then charge straight to 100% without unplugging. That single cycle resets the IC's reference points and the percentage readings stabilise. If jumping continues past three full cycles, check that the battery connector is fully seated on the mainboard.