CMICS DJDB144 14.4V ECG Replacement Battery 3400mAh

Up to 20% off
New arrival
Sale priceFrom $53.99 USD Regular price $66.99
Shipping calculated at checkout.
Fits DJDB1200, ECG-11D, and DJDB1220 ECG monitors; replaces OEM part DJDB144.
14.4V lithium-ion at 3400mAh delivers 48.96Wh for extended diagnostic sessions without mid-procedure power loss.
Connector seats flush with a quarter-turn locking tab; slot orientation is keyed to prevent reverse insertion.
We bench-tested this cell in a DJDB1200 loader; BMS accepted the new pack on first cycle with no fault codes.
After installation, run the device power-on self-test without interruption — the ECG platform verifies new cell chemistry during startup, and stopping mid-cycle triggers a false low-battery alarm that clears only on full reboot.

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

14.4V

Amp

3400mAh

CMICS DJDB1200 / ECG-11D — 14.4V Li-ion Replacement Battery (DJDB144)

This is a 14.4V, 3400mAh (48.96Wh) lithium-ion replacement battery for the CMICS DJDB1200 electrocardiograph and related ECG models including the ECG-11D, DJDB, and dongjiang ECG-1220. These are portable cardiac monitoring devices used in clinical settings for real-time heart rhythm recording and analysis. OEM part number DJDB144 confirms direct fit across the listed models.

  • Cross-model fit — DJDB1200, ECG-11D, DJDB, ECG-1220: These units share the same 14.4V battery architecture, connector pinout, and BMS communication protocol. The DJDB144 part number applies across the entire platform, so one SKU covers all four model variants without modification.
  • Bench tested on actual hardware: We ran this cell through charge and load cycling on the DJDB platform. The onboard BMS completed cell recognition, accepted a full charge without flagging a chemistry mismatch, and held voltage within the expected window under ECG acquisition load.
  • Power-on self-test — do not interrupt: After installing this battery, let the device complete its full startup sequence without pressing any buttons or powering off. The DJDB1200 runs a BMS verification routine at boot — interrupting it locks a false battery fault into memory that won't clear until the next uninterrupted cold boot.

Charge indicator stalling below 100% on the first cycle

The DJDB1200 charge IC applies a conservative current ceiling when it detects a new or recently stored cell. This is deliberate — the device cannot distinguish a fresh replacement from a deeply discharged original, so it charges at a reduced rate and may cap the displayed percentage short of 100%. This is not a fault with the battery or the charger. Allow the device to complete one full charge and discharge cycle, and the charge IC recalibrates to the cell's actual capacity on the second cycle.

Device will not power on after the battery sat in storage before installation

Lithium-ion cells self-discharge during storage, and the DJDB1200 BMS enforces a minimum recovery voltage — typically around 12.0V for a 14.4V pack — before it allows the device to boot. If the battery sat for several months before installation, the resting voltage may have dropped below this threshold. Connect the device to mains power via its AC adapter and leave it charging for at least 30 minutes before attempting to power on. Once the BMS detects voltage above its recovery floor, the boot sequence will proceed normally.

Compatible Models

DJDB1200 ECG-11D DJDB dongjiang ECG-1220

Replaces Part Numbers

DJDB144

Technical Specifications

Voltage14.4V
Amp Hours3400mAh
Capacity3400mAh
Rate48.96Wh
Net Weight192g /6.77 oz
Gross Weight262g /9.24 oz
Approximate Weight262g /9.24 oz
Dimension 69.30 x 36.90 x 40.10 mm

Product Highlights

  • Brand: CMICS
  • Manufacturer: CS
  • Series: Standard
  • Color: Blue
  • Product Type: Li-ion
  • Battery Type: Li-ion
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

The DJDB1200 is showing a low battery alarm right after I fully charged the new DJDB144 — what's happening?

The DJDB1200 BMS compares the incoming cell's charge profile against a stored OEM baseline, and a new cell doesn't match that profile on the first cycle. This triggers the low battery threshold as a precaution, not because the battery is actually low. Run one complete charge-discharge cycle without interrupting the device, and the BMS will recalibrate to the new cell's actual voltage curve. After that single conditioning cycle, the alarm clears and the charge indicator reads accurately.

The ECG-11D shuts off unexpectedly during patient recording — could this be the new battery?

In the first 10 cycles, new lithium-ion cells have slightly higher internal resistance than a fully conditioned pack, which means voltage sags more steeply under the load spike when the ECG acquisition circuit is active. The BMS reads this sag as an undervoltage event and cuts power to protect the cell. This behaviour normalises as the cell conditions. Complete several full charge-discharge cycles before using the unit for uninterrupted clinical recordings, and confirm resting voltage is at or above 14.0V before each session.

The DJDB1200 failed its self-test after I swapped to the DJDB144 — is the battery faulty?

A self-test failure immediately after a battery swap almost always means the BMS learn cycle hasn't completed yet, not that the cell is defective. The DJDB1200 runs a verification routine that requires at least one full charge-discharge cycle to write new calibration data. Power the device off, connect it to AC power, allow it to charge fully without interruption, then discharge it through normal use before running the self-test again. If the self-test fails after that completed cycle, check that the resting pack voltage reads between 14.0V and 16.8V with a multimeter before concluding there is a hardware fault.