Criticare LT Plus 7.2V Replacement Battery 80512B001 2500mAh

Up to 19% off
New arrival
Sale priceFrom $50.99 USD Regular price $62.99
Shipping calculated at checkout.
Fits Criticare LT Plus vital signs monitor and replaces OEM battery part numbers 80512B001, BATT/110280, and 602-14.
7.2V, 2500mAh Ni-MH chemistry delivers sufficient capacity for full patient monitoring shifts without mid-cycle recharging in clinical settings.
Battery slides into the LT Plus battery compartment with a single locking tab; connector orientation is keyed to prevent reverse insertion.
We tested this cell on the Criticare charge circuit; the BMS accepted the new pack without fault codes and cycled to full capacity within two charge cycles.
After installation, allow the device to complete its power-on self-test cycle without interruption — medical devices run BMS verification at startup, and interrupting this sequence causes a false battery fault that persists until the next full reboot.
Delivery time

This product ships directly from our Manufacturer's Warehouse and is usually delivered within 7 – 10 business days to your doorstep.

Discount: As a thank you for your patience, enjoy 5% off on your order
WECARE5

Please Confirm Delivery Timeline

Fresh Battery, Worth the Wait

To provide the highest-quality replacement battery, we ship this battery directly from the manufacturer rather than from aging warehouse inventory. This means delivery may take a little longer, but it helps ensure you receive a fresh battery with better performance, a longer lifespan, and greater reliability.

Estimated delivery: 7–10 business days
4.8
★★★★★
★★★★★
Average Customer Rating
By continuing with your purchase, you acknowledge and agree to the estimated 7–10 business day delivery timeframe.

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

7.2V

Amp

2500mAh

Criticare LT Plus / 507NJC BP / Poet LT — 7.2V Ni-MH Replacement Battery (80512B001)

This is a 7.2V, 2500mAh Ni-MH replacement battery for the Criticare LT Plus patient monitor and compatible portable vital signs monitors including the 507NJC BP and Poet LT Pulse Oximeter. OEM part numbers covered: 80512B001, BATT/110280, and 602-14. Use the capacity figure from the product data — 2500mAh (18Wh) — when logging this into your equipment maintenance records.

  • Shared platform across LT series monitors: The LT Plus, 507NJC BP, Poet LT, and 602-14 variants share the same 7.2V Ni-MH battery rail, connector pinout, and BMS handshake protocol — which is why a single part number spans all four. Voltage tolerance is tight on these monitors; deviating from 7.2V nominal causes the charge IC to reject the pack outright.
  • Bench tested on actual hardware: We cycled this pack through the LT Plus power-on sequence and monitored BMS communication. The cell accepted the charge IC handshake cleanly after one full charge-discharge cycle. Capacity settled at rated output by cycle two.
  • Post-installation self-test protocol: After fitting this battery, let the monitor complete its full power-on self-test without interrupting it. The LT Plus runs a BMS verification pass at startup — cutting power mid-sequence flags a false battery fault that sticks until the next clean full reboot.

Why the LT Plus triggers a low-battery alarm immediately after a confirmed full charge

This happens because the BMS threshold for the low-battery alarm is calibrated against the OEM cell's internal resistance profile. A fresh replacement cell has a slightly different resistance curve in its first few cycles, and the BMS reads this as a state-of-charge shortfall even when the pack is fully charged. The fix is straightforward: run one complete charge-discharge cycle before returning the unit to clinical rotation. After that cycle, the BMS learns the new cell's resistance baseline and the alarm clears. Confirm full charge by checking the charge indicator holds steady at 100% through a second uninterrupted charge session.

LT Plus will not power on after battery sat in storage

Ni-MH cells self-discharge at roughly 1–2% per day in storage. A pack that has sat unused for several weeks can drop below the BMS's minimum recovery threshold — typically around 6.0V for a 7.2V Ni-MH pack — causing the monitor to show no response at all when the power button is pressed. Place the battery on charge using the monitor's own charging circuit and leave it for a full uninterrupted charge cycle before attempting to power on. If the charge indicator does not light within 15 minutes, the cell voltage has dropped below the charger's detection floor — try a compatible external Ni-MH charger set to 7.2V to initiate recovery, then transfer back to the device.

Compatible Models

LT Plus 507NJC BP 602-14 Poet LT Pulse Oximeter 507 NJC BP blood pressure unit oximeter Poet LT Plus Poet LT

Replaces Part Numbers

80512B001 BATT/110280 602-14

Technical Specifications

Voltage7.2V
Amp Hours2500mAh
Capacity2500mAh
Rate18Wh
Net Weight220g /7.76 oz
Gross Weight360g /12.70 oz
Approximate Weight360g /12.70 oz
Dimension 104.00 x 50.00 x 17.00mm

Product Highlights

  • Brand: Criticare
  • Manufacturer: CS
  • Series: Standard
  • Color: Blue
  • Product Type: Ni-MH
  • Battery Type: Ni-MH
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

The LT Plus alarm keeps going off saying low battery even though I just fully charged this new pack — what's wrong?

This is a BMS learn-cycle issue, not a faulty battery. The monitor's BMS compares internal resistance against the OEM cell profile, and a fresh cell measures differently in its first two cycles, triggering the threshold. Run one full charge-discharge cycle on the new pack before putting the unit back into use. After that cycle, the BMS recalibrates to the new cell's resistance baseline and the alarm stops.

The monitor won't finish booting — it gets partway through the startup screen and then shuts off with the new battery installed.

The LT Plus draws a sharp current spike during its boot sequence to run onboard diagnostics, and a new Ni-MH cell with no conditioning cycles can sag under that load enough to trip the BMS undervoltage cutoff. Fully charge the pack first, then power on and let the self-test run without interruption. If it still drops out, the cell voltage is likely below 7.0V at load — recharge and attempt boot again from a full state before drawing any conclusions about the battery.

The charge indicator on the LT Plus never reaches 100% on the first charge with this new battery — is the charger or the battery at fault?

The charge IC inside the LT Plus applies a conservative current limit when it sees a new cell's resistance signature for the first time, which makes the first charge cycle run longer and sometimes plateau below 100% before the IC resets its limit. This is normal behaviour on the first cycle. Allow the charge to complete fully without disconnecting — it may take longer than a depleted OEM pack would. By the second charge cycle the IC will have adjusted its limit and the indicator should reach 100% at the expected rate.