Enersys HX330 UPS High Performance Replacement Battery
Couldn't load pickup availability
⚠️ Quick Reminder
🔹 Please ensure the original battery model number is listed in our product description and that your device model number matches for compatibility.
🔹 We only supply the batteries shown in the images. Device images are provided for reference only.
📸 Send Your Battery Photo / Unsure? Expert Help
Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.
POST YOUR IMAGE
Battery Care Guide
Battery Care Guide
Battery Usage and Maintenance Guidelines 🔋
Please read the following instructions carefully before using your new battery. Proper adherence will help ensure optimal performance and extended service life.
1. Cordless Phones, PDAs, and Power Tools (NiMH, NiCd, Lithium-Ion) 📱
Initial Charge
- Fully charge the battery overnight prior to first use.
Conditioning (First 2–6 Charge Cycles)
- Operate the device until the battery reaches approximately 20% capacity.
- Avoid premature recharging.
- Do not allow the battery to fully discharge during the initial cycles.
Post-Conditioning
- Recharge the battery only when necessary.
- These batteries are capable of approximately 500 charge cycles:
- Once daily → ~500 days
Twice daily → ~250 days
Note: Even a partial recharge is considered a full cycle.
2. Sealed Lead Acid (SLA) Batteries 💡
- No conditioning required.
- Maintain the battery in a fully charged state; avoid complete discharge.
- Capable of 300–400 charge cycles.
- Expected service life: 2–3 years, depending on usage conditions.
3. Laptop Batteries (Lithium-Ion) 💻
Initial Charge
- Fully charge the battery overnight prior to first use.
Conditioning (First 2–6 Charge Cycles)
- Charge fully, then discharge to approximately 20% capacity.
- Avoid complete discharge, as some devices may not detect a fully drained battery.
Post-Conditioning
- Minimize frequent plugging and unplugging.
- Allow the battery to discharge moderately at least once per month to maintain optimal performance.
- Occasional cycling is recommended to sustain battery health.
Professional Recommendation
Adhering to these guidelines will enhance battery longevity and ensure reliable performance.
For further assistance regarding your battery or order, our customer support team is available to provide guidance.
Delivery and Shipping
Delivery and Shipping
⚡ Everything You Need to Know About Shipping with BatteryWeb (USA)
We know reliable delivery matters when you need power fast. Here’s how BatteryWeb makes shipping easy across the USA:
🚚 Shipping & Delivery
Most orders ship next business day (some products like sealed lead acid may take a little longer).
Same-day shipping available if you order before 11:59 AM (delivery depends on the carrier).
We ship nationwide using FedEx, UPS, USPS, DHL, and regional ground carriers.
Shipping costs are calculated automatically at checkout based on weight, distance, and carrier.
Transit times shown are estimates only (business days, no weekends/holidays).
🌍 Shipping Restrictions
Lithium batteries cannot be shipped by USPS or air. They must go via FedEx Ground, UPS Ground, or DHL Ground.
PO Box deliveries are only available via USPS.
At this time, we do not ship lithium batteries to Puerto Rico. NiMH, NiCd, and Alkaline can be shipped.
📦 Important Notes
Double-check your shipping address! If an incorrect address is used and the order is returned, re-shipping costs are the buyer’s responsibility.
If a product is temporarily out of stock, we’ll notify you right away with the expected restock date—or issue a refund if you prefer.
💲 Currency & Pricing
All prices are shown in USD.
Orders shipped outside the USA may be subject to local taxes, customs fees, or import duties. These are the buyer’s responsibility.
⚡ At BatteryWeb, we’re committed to getting your batteries delivered quickly, safely, and affordably—so you’ll always have the power you need, when you need it.
Disclaimer
Disclaimer
⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.
🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.
🔹 Our products are generic replacement parts and are not affiliated with, endorsed by, or manufactured by the original equipment manufacturers (OEMs).
Volts & Amps
12 Volts | 97 Ah
Terminal Type
Internal Thread
Enersys HX330 Replacement UPS Battery — Compatible with HX330 UPS
The compatible replacement Enersys HX330 is purpose-built to restore and enhance UPS performance with reliable, high-rate discharge capability. If your UPS requires a dependable source of backup power, this replacement UPS battery offers the consistent output and standby resilience needed for critical systems. It’s an excellent choice for those seeking a high-performance UPS battery with proven longevity and dependable construction.
Key Specifications
- Model: Enersys HX330
- Brand: Enersys
- Voltage: 12 Volts
- Capacity: 97 Ah
- Terminal Type: Internal Thread
- High-rate discharge: 370 Watts per cell on 15-min rate at 1.67 Volts
- Self-discharge Rate: Less than 3% per month
- Expected Standby Life: Up to 10 years
- Cycle Life: Up to 300 cycles at 100% discharge (cycle service)
- Technology: Absorbent Glass Mat (AGM)
- Case: ABS (UL94 V-0) flame retardant case
- Construction: Spill proof / no-leak construction; can be operated in any position
- Warranty: 3 Year Warranty
- Certifications: UL Listed
- Condition: Brand New, Factory Fresh
- Design Note: High-rate discharge design for superior UPS performance
- Quality: Professionally tested and packaged; orders for in-stock items typically ship within 24 hours
Benefits
The Enersys HX330 replacement UPS battery is engineered for durability and long operational life. With AGM technology and a flame-retardant ABS case, this long-lasting battery is resistant to leaks and built for safe, maintenance-free use. Its spill-proof design and ability to operate in any orientation make it a versatile option for UPS cabinets, telecom enclosures, and mobile equipment.
Performance-focused applications benefit from the HX330’s high-rate discharge capability—delivering dependable power at 370 Watts per cell on a 15-minute discharge. This makes the battery ideal for maintaining uptime during outages, supporting emergency power systems, and powering critical tools and instrumentation. The low self-discharge rate and long standby life ensure the battery is ready when needed.
Backed by a 3 year warranty and UL listing, this high-performance UPS battery is a reliable replacement choice for IT managers, service technicians, and facility maintenance teams. Typical uses include UPS backup, emergency lighting and power, telecom systems, and portable power tools where dependable reserve capacity is essential.
Restore confidence in your backup power. Buy this replacement Enersys HX330 long-lasting battery today and take advantage of professional testing and fast shipping for in-stock orders.
-
Voltage
-
Amp Hours
-
Terminal Type
-
Length (in.)
-
Width (in.)
-
Height (in.)
-
Weight (lb.)
-
Warranty
-
Type
-
Manufacturer
-
Brand Replacement
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.