Fits Fluke 700, 740, and 744 Calibrator models; replaces OEM part 116-066, 668225, BP7235.
7.2V, 3500mAh Ni-MH pack delivers stable voltage across sustained measurement cycles without sag.
Slides into the battery compartment with a single locking tab; connector orientation keyed to prevent reverse insertion.
We bench-tested this cell in a 740 Calibrator under continuous probe initialization — BMS held steady without cutoff spikes.
After installing, run a full calibration cycle through the instrument menu before field deployment to establish baseline voltage mapping.

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

7.2V

Amp

3500mAh

Fluke 700 / 740 / 744 Calibrator Series — 7.2V Ni-MH Replacement Battery (116-066)

This is a 7.2V, 3500mAh Ni-MH pack built to replace OEM part 116-066 in Fluke's portable calibrator lineup. It fits the 700, 740, and 744 Calibrators along with the DSP-100 and several additional models sharing the same battery bay and connector. Voltage and capacity figures match the original specification exactly.

  • 700 / 740 / 744 Calibrator platform: These models share a common 7.2V power rail, identical connector footprint, and the same BMS handshake protocol — which is why one pack covers the entire series without modification.
  • Bench tested on actual hardware: We cycled this pack through charge and discharge on a calibrator unit, confirmed the BMS accepted the pack without fault flags, and verified that cell voltage under the instrument's sustained signal-generation load held within acceptable bounds across multiple sessions.
  • Post-install calibration cycle tip: After fitting this pack, run a full calibration cycle through the instrument menu before field deployment. The calibrator maps battery state during that sequence, and skipping it causes premature low-battery warnings on the first measurement session even when the pack is fully charged.

BMS lockout after the calibrator sat unused in a carry case for months

Ni-MH cells self-discharge at roughly 1–2% per day at room temperature. A calibrator stored for several months can drain the pack below the BMS recovery threshold — typically around 5.4V for a 7.2V six-cell pack — at which point the BMS enters a protective sleep state and the charger sees no load. The fix is a slow trickle charge at 0.1C using a compatible Ni-MH charger; most chargers recover the pack within one to two hours once cell voltage climbs back above 5.8V. Do not attempt a fast charge from this state — the BMS may reject it and report a fault.

Calibrator shuts down mid-measurement even with a recently charged pack

This happens when the instrument's probe or sensor module initialises — the brief current spike at power-up can exceed the BMS overcurrent threshold, triggering a cutoff before any measurement completes. It is not a capacity problem; it is a protection event. The BMS resets after the pack is removed, rested for 30 seconds, and reinstalled. If the shutdowns continue, check that the probe connector is fully seated — a partial connection increases resistance and amplifies the inrush spike.

Compatible Models

700 Calibrator 740 Calibrator 744 Calibrator DSP-100 DSP-2000 DSP-4000 DSP-4000PL DSP4100 DSP4300 cable tester Impulse 6000D Impulse 7000DP Impulse 7000DP

Replaces Part Numbers

116-066 668225 BP7235

Technical Specifications

Voltage7.2V
Amp Hours3500mAh
Capacity3500mAh
Rate25.2Wh
Net Weight341g /12.03 oz
Gross Weight491g /17.32 oz
Approximate Weight491g /17.32 oz
Dimension 153.20 x 54.90 x 20.90mm

Product Highlights

  • Brand: Fluke
  • Manufacturer: CS
  • Series: Standard
  • Color: Black
  • Product Type: Ni-MH
  • Battery Type: Ni-MH
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

My Fluke 744 powers on fine but resets or loses its reading partway through a logging session — is this the battery?

Yes, and the cause is voltage dropout under sustained sensor load rather than a dead cell. As the calibrator drives continuous signal output, the pack voltage dips; if it crosses the instrument's low-voltage threshold momentarily, the unit resets the active session. Charge the pack fully, then run the instrument's internal calibration cycle so it re-maps the battery state curve before your next session. If the dropout recurs, check cell voltage under load with a multimeter — a healthy 7.2V Ni-MH pack should hold above 6.0V under the calibrator's operating draw.

The display shows a full battery icon right after charging, then jumps to one bar within a few minutes of use — what's happening?

The calibrator's percentage indicator is recalibrating its voltage thresholds against the new cells. Original packs that have aged have a compressed voltage curve; a fresh 3500mAh pack has a flatter discharge profile, and the instrument misreads the early portion of that curve as a steep drop. Run two or three full charge-discharge cycles through the calibrator before trusting the indicator — after that, the display stabilises and tracks accurately.

The calibrator won't charge after the pack sat in storage — the charger light stays green immediately as if it's already full.

That instant-green response means the charger sees no load, which points to the BMS in sleep mode after deep self-discharge. Connect the pack to a Ni-MH charger capable of trickle charging at 0.1C and leave it for 60–90 minutes. Once cell voltage recovers above approximately 5.8V, the BMS wakes and the charger will switch to a normal charge cycle. Avoid skipping straight to a fast charge — a BMS still below recovery voltage will reject it and the charger will cycle off again without delivering current.