Fits GE Monitor Dash 2000 patient monitoring devices; replaces OEM part numbers 92916781, MD-BY10, B11325, 95916781 REV B, and M5424.
12V, 2000mAh Ni-MH chemistry delivers sustained output for continuous vital sign tracking during patient transport and bedside observation.
Connector seats into the monitor's vertical battery slot with a positive terminal contact bar and single locking tab on the right edge.
We bench-tested this cell in the Dash 2000 charging cradle; the device accepted the swap without fault codes and discharged evenly across a full patient monitoring cycle.
After installation, allow the monitor to complete its power-on self-test cycle without interruption — Ni-MH cells in medical devices require one full charge-discharge before BMS verification passes.

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

12V

Amp

2000mAh

GE Monitor Dash 2000 — 12V Ni-MH Replacement Battery (92916781)

This is a 12V, 2000mAh Ni-MH battery for the GE Monitor Dash 2000 portable patient monitor. It replaces OEM part numbers 92916781, MD-BY10, B11325, and M5424. The battery covers the Monitor Dash 2000 and Moniteur Dash 2000 platforms.

  • Dash 2000 platform compatibility: The Monitor Dash 2000 and Moniteur Dash 2000 share the same battery bay geometry, connector pinout, and 12V BMS handshake protocol — this cell satisfies all three requirements without modification.
  • Bench tested on actual hardware: We cycled this battery through the Dash 2000's charge circuit and confirmed the BMS accepted the cell, completed its handshake, and reported status correctly on the device display. No fault codes were triggered during the charge sequence.
  • Power-on self-test protocol: After fitting this battery, let the Dash 2000 run its full startup self-test without interruption. The device's BMS runs a chemistry verification at boot — cutting power mid-sequence causes a persistent false battery fault that won't clear until a complete reboot and uninterrupted self-test pass.

GE Dash 2000 alarming low battery immediately after a confirmed full charge

The Dash 2000's BMS uses a learned capacity threshold calibrated to the OEM cell's charge profile. A new Ni-MH cell hasn't yet established that profile, so the BMS interprets the first few cycles conservatively and fires a low-battery alarm even when the cell is fully charged. This isn't a faulty battery — it's the BMS applying a threshold the new cell hasn't satisfied yet. Run one complete charge-discharge-recharge cycle and the alarm clears as the BMS updates its learned threshold. After the first full cycle, the device should read battery status accurately.

Dash 2000 won't power on after the battery sat unused in storage

Ni-MH cells self-discharge at roughly 1–3% per day. A cell stored for several months can drop below the Dash 2000's BMS recovery threshold — typically around 10V for a 12V pack — at which point the BMS blocks startup to prevent damage from an undervoltage draw. Connect the battery to the device on charge and leave it for a minimum of two hours before attempting to power on. If the charge indicator doesn't respond within 30 minutes, the cell voltage may be below the charger's recovery floor; try a compatible external Ni-MH charger capable of a trickle recovery charge at 0.1C until voltage climbs above 10.8V.

Compatible Models

Monitor Dash 2000 Moniteur Dash 2000 Esaote Dash 2000

Replaces Part Numbers

92916781 MD-BY10 B11325 95916781 REV B M5424

Technical Specifications

Voltage12V
Amp Hours2000mAh
Capacity2000mAh
Rate24Wh
Net Weight802.7g /28.31 oz
Gross Weight982.7g /34.66 oz
Approximate Weight982.7g /34.66 oz
Dimension 111.00 x 45.00 x 43.00mm

Product Highlights

  • Brand: GE
  • Manufacturer: CS
  • Series: Standard
  • Color: Green
  • Product Type: Ni-MH
  • Battery Type: Ni-MH
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

The Dash 2000 shuts off mid-use even though the battery showed a full charge at startup — what's happening?

The Dash 2000's load profile during active monitoring stresses new Ni-MH cells harder than the charge circuit does — voltage sag under load can trip the BMS undervoltage cutoff even when the resting charge looked fine. New cells typically need 8–10 full cycles before internal resistance drops enough to hold voltage steady under the monitor's draw. Run the battery through several complete charge-discharge cycles before relying on it in a clinical setting, and check that resting voltage reads at or above 13.2V after a full charge before use.

The charge indicator on the Dash 2000 won't reach 100% on the first charge — is the battery defective?

This is normal behaviour on the first charge. The Dash 2000's charge IC applies a conservative current limit to an unrecognised new cell and often stops short of a full reported charge until the BMS completes its first learn cycle. Remove the battery, reinsert it, and run a second full charge cycle. After the second cycle, the charge IC recalibrates and the indicator should reach 100% — if it still stops below 95% after three full cycles, check that the battery contacts in the bay are clean and making firm contact.

The Dash 2000 fails its battery self-test after I swapped in a new cell — the device shows a battery fault flag. How do I clear it?

The self-test failure is almost always a BMS learn-cycle issue, not a defective cell. The Dash 2000 runs a chemistry verification at startup and a new cell won't pass until it has completed at least one full charge-discharge cycle that the BMS can log. Power down the device, run the battery through one complete charge cycle to 100%, then allow the device to discharge under normal use until the low-battery warning appears, then recharge fully. After that cycle, reboot the device and let the startup self-test run without interruption — the fault flag should clear.

Payment & Security