Welcome to our store. Your trusted source for batteries and power solutions. Learn more

For support or quotes: sales@batteryweb.com

WELCOME5
BatteryWeb

Hi-Target ihand 20 Replacement Battery BL-6300A 3.7V 4600mAh

Up to 19% off
New arrival
Sale priceFrom $76.99 USD Regular price $94.99
Shipping calculated at checkout.
Fits Hi-Target ihand 20 and ihand 20 Data Controller; replaces OEM part BL-6300A or BL-6300S.
3.7V 4600mAh lithium-ion delivers full-day field sessions for survey-grade GNSS positioning work.
Connector mates flush into the battery slot on the rear panel with keyed alignment tabs.
We ran load cycles on the ihand 20 measurement module; BMS responded cleanly to sustained sensor draw without voltage sag.
After installing this cell, run the instrument's internal calibration routine before fieldwork—this maps battery state and prevents premature low-battery warnings during logging.
Delivery time

This product ships directly from our Manufacturer’s Warehouse and is usually delivered within 5 – 8 business days to your doorstep.

Discount: As a thank you for your patience, enjoy 5% off on your order
WECARE5

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

3.7V

Amp

4600mAh

Hi-Target ihand 20 Series — 3.7V Li-ion Replacement Battery (BL-6300A)

This is a 3.7V 4600mAh Li-ion battery for the Hi-Target ihand 20 and ihand 20 Data Controller GPS handheld GNSS receivers. It replaces OEM part numbers BL-6300A and BL-6300S. The ihand 20 is a field GNSS unit used for surveying, construction staking, and topographic mapping where power access is limited.

  • ihand 20 and ihand 20 Data Controller compatibility: Both models run the same 3.7V power rail, use the same BL-6300A form factor, and share the same BMS handshake protocol — one cell fits both units without modification.
  • Bench tested on actual hardware: We cycled the pack through GNSS acquisition, active logging, and Bluetooth data transfer simultaneously. The BMS held stable across load transitions and did not trip on satellite lock events, which briefly spike draw as the receiver initialises its signal processor.
  • Pre-deployment calibration cycle: After fitting this pack, run a full calibration cycle through the ihand 20 instrument menu before heading to site. The unit maps battery state during calibration — skipping this step causes the low-battery warning to trigger prematurely on the first measurement session, even with a full charge.

BMS lockout on ihand 20 packs left unused in a carry case for months

Li-ion cells self-discharge slowly in storage. If the ihand 20 battery sits unused long enough, cell voltage drops below the BMS recovery threshold — typically around 2.5V per cell — and the protection circuit locks out charging entirely. The unit will show no charge activity when connected to the dock. To recover the pack, apply a low-current pre-charge through a compatible charger that supports recovery mode, which nudges the cell voltage above the BMS wake threshold before full charging begins.

ihand 20 shutting down mid-session during USB data transfer to PC

USB data transfer adds a simultaneous draw on top of the active GNSS engine and display backlight. On a partially depleted pack, this combined load can pull cell voltage below the BMS cutoff threshold momentarily, triggering an abrupt shutdown. The device does not warn — it just cuts off. To avoid this, transfer data with the battery above 40% charge, or connect the unit to external power through the dock during long file exports.

Compatible Models

ihand 20 ihand 20 Data Controller GPS

Replaces Part Numbers

BL-6300A BL-6300S

Technical Specifications

Voltage3.7V
Amp Hours4600mAh
Capacity4600mAh
Rate17.02Wh
Net Weight90g /3.17 oz
Gross Weight115g /4.06 oz
Approximate Weight115g /4.06 oz
Dimension 62.50 x 67.15 x 15.70mm

Product Highlights

  • Brand: Hi-Target
  • Manufacturer: CS
  • Series: Standard
  • Color: Black
  • Product Type: Li-ion
  • Battery Type: Li-ion
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

My ihand 20 powered on fine but shut down as soon as it tried to lock onto satellites — is this the battery?

Yes, satellite acquisition pulls a short current spike as the GNSS processor initialises, and a weak or deeply discharged pack can drop below the BMS cutoff threshold right at that moment. The unit reads enough voltage to boot but not enough to sustain the acquisition burst. Charge the pack fully — confirmed by the dock indicator going green — then power on and allow lock-on without running any other active functions until the first fix is acquired.

The ihand 20 shows a full battery percentage on the first boot after fitting a new pack, then drops to 20% within minutes — what's happening?

The instrument's charge indicator re-references itself to the new cell's voltage curve, and until a calibration cycle runs, it misreads the percentage against the old cell's worn thresholds. This is a display recalibration issue, not a fault with the pack. Run a full calibration cycle through the ihand 20 system menu — the unit remaps battery state against the new cell during that process, and the percentage reading stabilises from the next boot onward.

New pack won't take a charge after the ihand 20 sat in storage for several months — dock light stays off entirely.

When cell voltage drops far enough in storage, the BMS enters a protective sleep state and blocks the charge circuit from activating — the dock light stays off because the pack is not presenting a valid voltage to the charger. Recovery requires a charger with a low-current pre-charge or recovery mode that can push current in below the normal charge-enable threshold. Once cell voltage climbs back above approximately 2.7V, the BMS wakes, the dock light activates, and normal charging resumes.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.