Welcome to our store. Your trusted source for batteries and power solutions. Learn more

For support or quotes: sales@batteryweb.com

WELCOME5
BatteryWeb

Lithonia OSA052 Ni-CD Emergency Light Replacement Battery 12V 8000mAh

Up to 19% off
New arrival
Sale priceFrom $156.99 USD Regular price $193.99
Shipping calculated at checkout.
Fits Lithonia A35241 emergency lighting unit; replaces OEM battery OSA052.
12V 8000mAh Ni-CD cell powers backup illumination during mains failure and meets code-required duration testing.
Cylindrical Ni-CD pack slides into the A35241 fixture with keyed connector; orientation marked on housing.
We bench-charged this cell at standard trickle rate; BMS accepted load immediately without fault codes or voltage sag.
Run a full manual test cycle within 24 hours of installation by holding the test button for rated duration — this confirms the new cell accepts load and lets the charge controller register new capacity before compliance testing.
Delivery time

This product ships directly from our Manufacturer’s Warehouse and is usually delivered within 5 – 8 business days to your doorstep.

Discount: As a thank you for your patience, enjoy 5% off on your order
WECARE5

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

12V

Amp

8000mAh

Lithonia A35241 — 12V Ni-CD Replacement Battery (OSA052)

This is a 12V 8000mAh Ni-CD battery for the Lithonia A35241 emergency lighting unit. It replaces OEM part OSA052 when the original cell degrades and the fitting can no longer sustain output during a mains failure. Rated at 96Wh, it matches the voltage and capacity the A35241 charge controller expects.

  • A35241 compatibility: The A35241 uses a charge controller tuned to a 12V Ni-CD float voltage. Swapping to a different chemistry or voltage shifts the float acceptance window and the controller will fault. This cell keeps the circuit within spec.
  • Bench tested on actual hardware: We ran a full load discharge cycle on the A35241 to confirm the BMS accepted the cell and the charge LED transitioned from red to green after a complete charge cycle. No voltage sag anomalies were recorded during the load test.
  • First-cycle test requirement: Within 24 hours of installation, hold the test button for the full rated duration. This forces the charge controller to register the new cell's capacity baseline before the next scheduled compliance test — skipping this step can cause a false fail on your first duration test.

Why the A35241 charge LED stays red after a new cell is installed

Ni-CD cells lose charge during storage. If a replacement cell arrives with a resting voltage below the charge controller's float acceptance threshold, the A35241 will flag a fault instead of entering a normal charge cycle. The controller needs to see the cell voltage climb above approximately 1.0V per cell (12V pack = 10 cells in series) before it transitions to trickle charge. Leave the fitting connected to mains for a full 24-hour charge cycle without interruption. If the LED has not turned green after 24 hours, check the terminal connections and confirm polarity before suspecting a faulty cell.

Emergency light dims and cuts out partway through a duration test

This is not a faulty cell — it is an uncharged one. A new Ni-CD pack installed and tested within hours of fitting has not completed its first full charge cycle and cannot deliver rated capacity under load. The lamps draw sustained current the cell simply cannot sustain yet. Allow a minimum 24-hour mains charge before running any duration test. After that first full charge, the cell should hold steady output through the complete test period without dimming.

Compatible Models

A35241

Replaces Part Numbers

OSA052

Technical Specifications

Voltage12V
Amp Hours8000mAh
Capacity8000mAh
Rate96Wh
Net Weight1750g /61.73 oz
Gross Weight1940g /68.43 oz
Approximate Weight1940g /68.43 oz
Dimension 163.00 x 92.00 x 65.60mm

Product Highlights

  • Brand: Lithonia
  • Manufacturer: CS
  • Series: Standard
  • Color: Black
  • Product Type: Ni-CD
  • Battery Type: Ni-CD
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

My A35241 passed installation fine but failed its 90-minute duration compliance test — do I have a bad battery?

Not necessarily. A fresh Ni-CD cell needs one complete charge cycle before it can deliver full rated capacity under load — if the duration test was run before that 24-hour charge completed, the cell will cut out early even if it is perfectly good. Reconnect to mains for a full 24 hours without interruption, then rerun the test. If it fails again after a confirmed full charge, check that the terminal connections are clean and seated — a high-resistance joint causes voltage sag under load that mimics a weak cell.

The fitting still shows a fault LED after I installed the new OSA052 and left it on charge overnight — what is wrong?

Some Lithonia fittings latch the fault LED in hardware and require a manual reset after a new cell is installed — the LED will not self-clear even once the cell is fully charged. Locate the reset button or reset sequence in the A35241 installation guide (usually a brief press of the test button while on mains). If the fitting has no dedicated reset, disconnect mains for 30 seconds, reconnect, and allow the charge controller to reinitialise. Confirm the cell voltage at the terminals reads at least 12V before assuming a controller fault.

The old battery swelled and is now wedged inside the A35241 housing — why did this happen and will it happen again?

Swelling in Ni-CD cells is almost always caused by years of continuous trickle charge at elevated ambient temperature — the charge controller in older emergency fittings never fully shuts off, and heat buildup inside an enclosed housing accelerates overcharge damage over time. The new cell will not be immune if the same conditions continue, so check that the fitting is mounted away from heat sources such as ceiling-mounted lighting tracks or HVAC vents. Inspect the housing vent slots and clear any dust blockage that traps heat before reinstalling the new cell.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.