Battery Care Guide
Battery Care Guide
Battery Usage and Maintenance Guidelines 🔋
Please read the following instructions carefully before using your new battery. Proper adherence will help ensure optimal performance and extended service life.
1. Cordless Phones, PDAs, and Power Tools (NiMH, NiCd, Lithium-Ion) 📱
Initial Charge
- Fully charge the battery overnight prior to first use.
Conditioning (First 2–6 Charge Cycles)
- Operate the device until the battery reaches approximately 20% capacity.
- Avoid premature recharging.
- Do not allow the battery to fully discharge during the initial cycles.
Post-Conditioning
- Recharge the battery only when necessary.
- These batteries are capable of approximately 500 charge cycles:
- Once daily → ~500 days
Twice daily → ~250 days
Note: Even a partial recharge is considered a full cycle.
2. Sealed Lead Acid (SLA) Batteries 💡
- No conditioning required.
- Maintain the battery in a fully charged state; avoid complete discharge.
- Capable of 300–400 charge cycles.
- Expected service life: 2–3 years, depending on usage conditions.
3. Laptop Batteries (Lithium-Ion) 💻
Initial Charge
- Fully charge the battery overnight prior to first use.
Conditioning (First 2–6 Charge Cycles)
- Charge fully, then discharge to approximately 20% capacity.
- Avoid complete discharge, as some devices may not detect a fully drained battery.
Post-Conditioning
- Minimize frequent plugging and unplugging.
- Allow the battery to discharge moderately at least once per month to maintain optimal performance.
- Occasional cycling is recommended to sustain battery health.
Professional Recommendation
Adhering to these guidelines will enhance battery longevity and ensure reliable performance.
For further assistance regarding your battery or order, our customer support team is available to provide guidance.
Delivery and Shipping
Delivery and Shipping
⚡ Everything You Need to Know About Shipping with BatteryWeb (USA)
We know reliable delivery matters when you need power fast. Here’s how BatteryWeb makes shipping easy across the USA:
🚚 Shipping & Delivery
Most orders ship next business day (some products like sealed lead acid may take a little longer).
Same-day shipping available if you order before 11:59 AM (delivery depends on the carrier).
We ship nationwide using FedEx, UPS, USPS, DHL, and regional ground carriers.
Shipping costs are calculated automatically at checkout based on weight, distance, and carrier.
Transit times shown are estimates only (business days, no weekends/holidays).
🌍 Shipping Restrictions
Lithium batteries cannot be shipped by USPS or air. They must go via FedEx Ground, UPS Ground, or DHL Ground.
PO Box deliveries are only available via USPS.
At this time, we do not ship lithium batteries to Puerto Rico. NiMH, NiCd, and Alkaline can be shipped.
📦 Important Notes
Double-check your shipping address! If an incorrect address is used and the order is returned, re-shipping costs are the buyer’s responsibility.
If a product is temporarily out of stock, we’ll notify you right away with the expected restock date—or issue a refund if you prefer.
💲 Currency & Pricing
All prices are shown in USD.
Orders shipped outside the USA may be subject to local taxes, customs fees, or import duties. These are the buyer’s responsibility.
⚡ At BatteryWeb, we’re committed to getting your batteries delivered quickly, safely, and affordably—so you’ll always have the power you need, when you need it.
Disclaimer
Disclaimer
⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.
🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.
🔹 Our products are generic replacement parts and are not affiliated with, endorsed by, or manufactured by the original equipment manufacturers (OEMs).
Volts & Amps
12 Volts | 7.5 Ah
Terminal Type
F2
SigmasTek SP12-7.5HR Replacement Battery Set for Merich 400
Restore reliable backup power to your Merich 400 with this replacement UPS battery set. This kit includes 2 SigmasTek SP12-7.5HR batteries (12 Volts, 7.5 AH) engineered for high-rate discharge performance. Whether you need dependable runtime for servers, network equipment, or emergency systems, these factory-fresh batteries offer the consistency and safety certifications required for critical UPS applications.
Key Specifications
- Brand: SigmasTek
- Model: SP12-7.5HR
- Voltage: 12 Volts
- Capacity: 7.5 AH
- Quantity: 2 batteries per set
- Design: High Rate Discharge Design
- Construction: Valve Regulated Spill Proof
- Self-discharge: Low self-discharge
- Durability: High vibration resistance
- Certifications: U.L. Recognized and CE Certified
- Condition: Brand new, factory fresh
- Warranty: 1 Year Warranty
- Compatibility note: Requires use of existing cables and hardware from original configuration
- Compatible UPS Model: Merich 400
Benefits
Choose a long-lasting battery solution that emphasizes durability and dependable performance. The SigmasTek cells feature valve-regulated, spill-proof construction and high vibration resistance, ensuring they hold up through installation and service cycles. The high-rate discharge design provides the surge capability necessary for brief, high-power events—making this a high-performance UPS battery for the Merich 400.
Low self-discharge extends shelf life and readiness for use, while U.L. and CE certifications underscore compliance with safety and manufacturing standards. Each battery is brand new and factory tested to meet or exceed OEM requirements, giving you a replacement UPS battery you can trust to protect critical systems.
Typical applications include Uninterruptible Power Supply (UPS) units such as the Merich 400, emergency power supply systems, and battery-powered tools that rely on short-duration, high-output battery performance. Whether replacing old batteries or preparing spares, this set offers a reliable path to restored uptime and protection.
Ready to upgrade your Merich 400 backup power? Order this high-performance, long-lasting battery set now. In-stock orders generally ship within 24 hours. For assistance, call or email our support team. Secure your critical loads with a trusted replacement UPS battery today.
-
Voltage
-
Amp Hours
-
Terminal Type
-
Length (in.)
-
Width (in.)
-
Height (in.)
-
Weight (lb.)
-
Warranty
-
Type
-
Manufacturer
-
Brand Replacement
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.