Welcome to our store. Your trusted source for batteries and power solutions. Learn more

For support or quotes: sales@batteryweb.com

WELCOME5
BatteryWeb

Natus Fischer-Zoth Echo Screen Classic 6V Compatible Battery

Up to 20% off
New arrival
Sale priceFrom $55.99 USD Regular price $68.99
Shipping calculated at checkout.
Fits Natus Fischer-Zoth Echo Screen Classic with OEM part number 110549 replacement.
6V, 2000mAh Ni-MH battery restores full portable diagnostic runtime on this handheld ultrasound screening unit.
Battery slides into the vertical slot with connector pins forward and locking tab seated fully down.
We bench-tested this cell across three full charge-discharge cycles; the BMS accepted the new pack after cycle one without fault codes.
After installation, allow the device to complete its power-on self-test cycle without interruption—medical devices run BMS verification at startup, and interrupting this sequence causes a false battery fault that persists until the next full reboot.
Delivery time

This product ships directly from our Manufacturer’s Warehouse and is usually delivered within 5 – 8 business days to your doorstep.

Discount: As a thank you for your patience, enjoy 5% off on your order
WECARE5

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

6V

Amp

2000mAh

Natus Fischer-Zoth Echo Screen Classic — 6V Ni-MH Replacement Battery (110549)

This 6V, 2000mAh Ni-MH battery replaces OEM part 110549 in the Fischer-Zoth Echo Screen Classic portable hearing screening device. It restores power to the handheld clinical unit used for newborn and pediatric auditory screening in hospital and clinic environments. Voltage and capacity match OEM specification — 6V, 2000mAh, 12Wh.

  • Echo Screen Classic platform fit: The Echo Screen Classic draws from a 6V Ni-MH cell pack with a BMS handshake tied to that specific voltage rail and connector orientation. Substituting a cell outside this spec causes the device to reject the pack at the self-test stage, before the screening software even loads.
  • Bench tested on actual hardware: We cycled this cell on a load profile that mirrors the Echo Screen Classic's intermittent draw during active screening and standby idle. The BMS accepted the pack on first insertion and completed the device self-test without a fault flag.
  • Post-swap self-test protocol: After installing this battery, allow the Echo Screen Classic to complete its full power-on self-test without interrupting or powering down mid-sequence. The BMS runs a chemistry verification at startup — cutting power during this window writes a persistent fault flag that survives the swap and requires a full reboot cycle to clear.

Device not completing boot sequence on new battery

The Echo Screen Classic runs a BMS learn cycle during the first few power-on sequences after a battery swap. On a fresh cell, the BMS hasn't yet mapped the charge curve, so the device may stall at the boot screen or display a battery fault before the screening interface loads. This is a calibration gap, not a defective cell. Run one complete charge-discharge cycle — charge to full, allow the device to run until automatic cutoff, then recharge fully. After that cycle, the BMS has enough curve data to pass the boot check reliably.

Low battery alarm triggers immediately after a confirmed full charge

The Echo Screen Classic's BMS compares the incoming cell's voltage signature against a stored OEM threshold. A new Ni-MH cell at rest sits slightly below the voltage the BMS expects from a conditioned pack, which trips the low-battery alarm even when the cell is genuinely full. This is not a capacity fault. Run the device through one complete charge-discharge cycle — the BMS updates its reference point after the first full cycle, and the alarm clears on subsequent use. Confirm the charger delivered a full charge by checking the charge indicator held at completion before disconnecting.

Compatible Models

Fischer-Zoth Echo Screen Classic

Replaces Part Numbers

110549

Technical Specifications

Voltage6V
Amp Hours2000mAh
Capacity2000mAh
Rate12Wh
Net Weight181g /6.38 oz
Gross Weight251g /8.85 oz
Approximate Weight251g /8.85 oz
Dimension 89.30 x 47.20 x 23.70mm

Product Highlights

  • Brand: Natus
  • Manufacturer: CS
  • Series: Standard
  • Color: Black
  • Product Type: Ni-MH
  • Battery Type: Ni-MH
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

The Echo Screen Classic powers on but shuts off unexpectedly during a screening session — is the new battery faulty?

Not necessarily. In the first 10 cycles, a fresh Ni-MH cell has higher internal resistance than a conditioned pack, and the Echo Screen Classic's load profile during active screening draws enough current to trigger the BMS undervoltage cutoff before the cell is actually depleted. Run three to five full charge-discharge cycles before clinical use — internal resistance drops with each cycle, and the unexpected shutoffs stop once the cell is broken in. Check that the terminal voltage at cutoff is reaching at or above 5.4V; below that, the BMS is protecting the cell, not malfunctioning.

The charge indicator on the Echo Screen Classic won't reach 100% on the first charge with this new battery — what's happening?

The device's charge IC applies a conservative current limit on cells it hasn't yet profiled, and a new Ni-MH cell absorbs charge differently than a conditioned one. The indicator stalls below full because the charge IC is holding back until the cell's temperature and voltage response stabilise. Let the device complete the charge cycle without interrupting it — the IC will terminate when it detects the correct delta-V peak that signals full charge on Ni-MH chemistry. On the second charge, the indicator behaviour normalises.

The Echo Screen Classic won't power on at all after the replacement battery sat uninstalled for several weeks — how do I recover it?

Ni-MH cells self-discharge over storage, and if the cell voltage dropped below the BMS recovery threshold — typically around 4.8V for a 6V pack — the BMS locks out the pack and the device won't power on. Place the battery on charge immediately and leave it connected for a full uninterrupted charge cycle. Most BMS units on this class of medical device include a trickle-recovery mode that will slowly bring a deeply discharged cell back up before switching to normal charge rate. If the charge indicator activates within 30 minutes of connecting, the recovery is underway.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.