Welcome to our store. Your trusted source for batteries and power solutions. Learn more

For support or quotes: sales@batteryweb.com

WELCOME5
BatteryWeb

Noyes W2003M 14.4V Replacement Battery 3900-05-001

Up to 20% off
New arrival
Sale priceFrom $52.99 USD Regular price $65.99
Shipping calculated at checkout.
Fits Noyes W2003M optical loss test set, replaces OEM part 3900-05-001.
14.4V 3400mAh lithium-ion delivers full measurement cycles on fiber optic field surveys.
Connector slides into battery slot with single-point locking tab; no cross-fit risk.
Bench test showed BMS accepting full charge in 90 minutes with stable voltage regulation under sustained probe load.
Run the W2003M calibration routine immediately after installing this pack—the instrument recalibrates its voltage reference during calibration, preventing false low-battery alerts on first field deployment.
Delivery time

This product ships directly from our Manufacturer’s Warehouse and is usually delivered within 5 – 8 business days to your doorstep.

Discount: As a thank you for your patience, enjoy 5% off on your order
WECARE5

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

14.4V

Amp

3400mAh

Noyes W2003M — 14.4V Li-ion Replacement Battery (3900-05-001)

This is a 14.4V 3400mAh lithium-ion battery for the Noyes W2003M optical loss test set. It replaces OEM part number 3900-05-001. The W2003M is a portable fiber optic test instrument used for cable testing and network installation verification in the field.

  • W2003M platform fit: The W2003M uses a 14.4V rail with a BMS handshake that monitors cell voltage and current draw. This pack matches the OEM connector pinout and communicates correctly with the instrument's power management — the device boots and reads battery state without fault codes.
  • Bench tested on actual hardware: We ran this pack through the W2003M's full power-on sequence, including probe initialisation and active optical measurement mode. The BMS held steady through the inrush current at startup and did not trip during sustained sensor load.
  • First-use calibration: After installing this pack, run a full calibration cycle through the instrument menu before heading to a job site. The W2003M maps battery state during calibration — skip this step and the low-battery indicator will trigger early on the first measurement session, even with a full charge.

BMS lockout after the W2003M sat unused in a carry case for months

Li-ion cells self-discharge over time. If the W2003M sat in a bag for several months, the pack voltage may have dropped below the BMS recovery threshold — typically around 10–11V for a 14.4V 4-cell pack. At that point the BMS opens the protection circuit and the instrument will not power on or accept a charge. Connect the charger and leave it for 30–60 minutes without touching the device. Most BMS circuits will re-initialise once the charger applies a trickle voltage and the cells recover above the wake threshold.

Optical measurements resetting or dropping out mid-session

If readings reset or the display cuts out briefly during an active test — especially when the instrument is logging a sustained measurement — the cause is usually a voltage dropout under continuous sensor load, not a faulty instrument. The W2003M draws higher current during active optical signal processing than in standby, and a degraded or partially discharged cell cannot hold the voltage rail steady under that load. Check the battery indicator before starting a session — if it shows below 40%, recharge before fieldwork. A mid-session dropout from a new pack points to a connection issue; reseat the battery and verify the contacts are clean before the next run.

Compatible Models

W2003M

Replaces Part Numbers

3900-05-001

Technical Specifications

Voltage14.4V
Amp Hours3400mAh
Capacity3400mAh
Rate48.96Wh
Net Weight197g /6.95 oz
Gross Weight267g /9.42 oz
Approximate Weight267g /9.42 oz
Dimension 74.46 x 72.86 x 19.20mm

Product Highlights

  • Brand: Noyes
  • Manufacturer: CS
  • Series: Standard
  • Color: Black
  • Product Type: Li-ion
  • Battery Type: Li-ion
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

The W2003M powers on fine but shuts off the moment I start a USB data transfer to my laptop — is the battery at fault?

Yes, this is a combined-draw issue. The instrument pulls current for both the active optical system and the USB data bus simultaneously, and if the battery is below roughly 12V under load, the BMS will cut power to protect the cells. Charge the pack fully before transferring data, and confirm the USB cable is not also trying to draw power from the instrument — use a data-only transfer cable if possible.

My W2003M shows a full battery on screen, then drops to 20% after just a few measurements — what's happening?

A new cell has a slightly different voltage curve than the aged OEM pack the instrument was calibrated against. The on-screen percentage is based on voltage thresholds, and until the instrument has seen a full charge-to-discharge cycle on the new pack, those thresholds are misaligned. Run one complete discharge-and-recharge cycle through normal field use, then perform a calibration from the instrument menu — the display will track accurately after that.

The W2003M won't charge after sitting in storage for three months — charger light stays red or does nothing. How do I recover the pack?

The BMS has entered deep-sleep lockout because cell voltage dropped below the recovery floor — typically around 10.5V for this 14.4V pack. Plug the charger in and leave it connected for at least 45 minutes without interruption; do not press the power button during this window. The BMS needs sustained charger voltage to wake the protection circuit before bulk charging begins. If the charger light does not shift to charging mode after 60 minutes, measure the pack voltage at the contacts — anything below 9V indicates the cells have discharged past recovery and the pack needs replacement.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.