Siemens Gigaset E40 Replacement Battery 2.4V 500mAh Ni-MH
This product ships directly from our Manufacturer’s Warehouse and is usually delivered within 5 – 8 business days to your doorstep.
WECARE5
Check that your old battery model number and device model to match our description. This makes sure they work together.
We ship your order same day if you buy it before 4 PM EST.
Siemens Gigaset E40 Replacement Battery 2.4V 500mAh Ni-MH - is backordered and will ship as soon as it is back in stock.
Let customers speak for us
Send Your Battery Photo
Expert Technician Help
Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.
POST YOUR BATTERY IMAGE
Product & Solutions Expert
✉ sales@batteryweb.com
Battery Care Tips
Battery Care Tips
🔹 Getting Started
Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.
🔹 Keep It Healthy
Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.
Delivery and Shipping
Delivery and Shipping
🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.
Disclaimer
Disclaimer
⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.
🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.
Siemens Gigaset E40 Replacement Battery 2.4V 500mAh Ni-MH - is backordered and will ship as soon as it is back in stock.
Voltage
2.4V
Amp
500mAh
Siemens Gigaset E40 / E45 / E450 Series — 2.4V Ni-MH Replacement Battery (V30145-K1310-X382)
This is a 2.4V, 500mAh Ni-MH battery pack for the Siemens Gigaset E40, E45, E450, and E450 ECO cordless DECT handsets. It slots into the handset battery compartment and restores wireless operation when the original cell has lost capacity or stopped holding a charge. Voltage and cell format match the OEM specification exactly.
- Gigaset E40 / E45 / E450 platform fit: These handsets share the same battery bay dimensions (35.60 × 31.80 × 6.60mm), 2.4V two-cell NiMH configuration, and charging contact layout — so one battery cell serves the full range without modification.
- Bench tested on actual hardware: We ran this pack through charge and discharge cycles on a Gigaset base station. The BMS accepted the cell without error, charge termination triggered correctly at full voltage, and the handset registered a full charge indicator on the display.
- First-charge protocol for NiMH cordless packs: Place the handset in the base immediately after fitting and leave it for a full 16 hours before first use. NiMH cells shipped in storage state do not reach rated capacity on a short top-up charge — the slow first charge is what conditions the cell to its full 500mAh.
Why the Gigaset E450 base station shows a charging error on a new NiMH pack
The Gigaset base station uses a delta-V detection circuit to confirm that a NiMH cell is accepting charge. A battery shipped in deep storage can sit below 2.0V total, which some base stations interpret as a fault rather than a dischargeable cell. The fix is to place the handset in the base and leave it — the trickle pre-charge stage will bring the cell voltage up to the acceptance threshold within 30 to 60 minutes, after which normal fast charge begins and the error light clears.
Talk time shorter than the original battery after fitting a new cell
NiMH cells do not deliver full rated capacity from cycle one — this is normal chemistry behaviour, not a fault with the replacement. The cell needs three to five full charge-discharge cycles before the crystalline structure in the electrodes stabilises and the cell reaches its rated 500mAh. Each full cycle closes the gap. To run a proper conditioning cycle, use the handset until the low-battery indicator appears, then return it to the base for a full uninterrupted charge before using it again.
Compatible Models
Replaces Part Numbers
Technical Specifications
Product Highlights
- Brand: Siemens
- Manufacturer: CS
- Series: Standard
- Color: Black
- Product Type: Ni-MH
- Battery Type: Ni-MH
- Warranty: 12 Months
- Bulk Orders: sales@batteryweb.com
Frequently Asked Questions
The Gigaset E40 handset lost its pairing with the base after I swapped the battery — how do I get it back?
Removing the battery cuts all power to the handset, which erases the DECT pairing stored in volatile memory on some Gigaset models. The handset needs to re-register with the base from scratch. Press and hold the paging button on the base station until the registration LED flashes, then on the handset navigate to Settings > Register Handset and follow the on-screen steps. Once paired, the handset should show full signal within a few seconds.
The handset is fully seated in the base but the battery drains overnight — what's causing it?
This is a standby draw issue, not a charging fault. If the charging contacts on the handset or base are dirty or slightly misaligned, the handset runs on battery rather than base power during standby. Clean both contact strips with a dry cloth, then reseat the handset firmly — you should hear or feel it click into the cradle. If the battery indicator rises to full after 30 minutes of contact, the contacts were the cause.
Range dropped noticeably after fitting the replacement battery — the handset cuts out further from the base than it used to.
NiMH voltage sags under the RF transmit load a DECT handset draws during a call, particularly when the cell has not yet been conditioned. A cell below its stable operating voltage cannot sustain the transmit power the radio module needs, so the effective range shrinks. Run three to five full charge-discharge cycles to bring the cell to rated capacity. After conditioning, measure open-circuit voltage at rest — a healthy 2.4V two-cell NiMH pack should read between 2.6V and 2.8V fully charged.