Upsonic IP 6000 UPS High Performance Replacement Battery Set
Couldn't load pickup availability
⚠️ Quick Reminder
🔹 Please ensure the original battery model number is listed in our product description and that your device model number matches for compatibility.
🔹 We only supply the batteries shown in the images. Device images are provided for reference only.
📸 Send Your Battery Photo / Unsure? Expert Help
Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.
POST YOUR IMAGE
Battery Care Guide
Battery Care Guide
Battery Usage and Maintenance Guidelines 🔋
Please read the following instructions carefully before using your new battery. Proper adherence will help ensure optimal performance and extended service life.
1. Cordless Phones, PDAs, and Power Tools (NiMH, NiCd, Lithium-Ion) 📱
Initial Charge
- Fully charge the battery overnight prior to first use.
Conditioning (First 2–6 Charge Cycles)
- Operate the device until the battery reaches approximately 20% capacity.
- Avoid premature recharging.
- Do not allow the battery to fully discharge during the initial cycles.
Post-Conditioning
- Recharge the battery only when necessary.
- These batteries are capable of approximately 500 charge cycles:
- Once daily → ~500 days
Twice daily → ~250 days
Note: Even a partial recharge is considered a full cycle.
2. Sealed Lead Acid (SLA) Batteries 💡
- No conditioning required.
- Maintain the battery in a fully charged state; avoid complete discharge.
- Capable of 300–400 charge cycles.
- Expected service life: 2–3 years, depending on usage conditions.
3. Laptop Batteries (Lithium-Ion) 💻
Initial Charge
- Fully charge the battery overnight prior to first use.
Conditioning (First 2–6 Charge Cycles)
- Charge fully, then discharge to approximately 20% capacity.
- Avoid complete discharge, as some devices may not detect a fully drained battery.
Post-Conditioning
- Minimize frequent plugging and unplugging.
- Allow the battery to discharge moderately at least once per month to maintain optimal performance.
- Occasional cycling is recommended to sustain battery health.
Professional Recommendation
Adhering to these guidelines will enhance battery longevity and ensure reliable performance.
For further assistance regarding your battery or order, our customer support team is available to provide guidance.
Delivery and Shipping
Delivery and Shipping
⚡ Everything You Need to Know About Shipping with BatteryWeb (USA)
We know reliable delivery matters when you need power fast. Here’s how BatteryWeb makes shipping easy across the USA:
🚚 Shipping & Delivery
Most orders ship next business day (some products like sealed lead acid may take a little longer).
Same-day shipping available if you order before 11:59 AM (delivery depends on the carrier).
We ship nationwide using FedEx, UPS, USPS, DHL, and regional ground carriers.
Shipping costs are calculated automatically at checkout based on weight, distance, and carrier.
Transit times shown are estimates only (business days, no weekends/holidays).
🌍 Shipping Restrictions
Lithium batteries cannot be shipped by USPS or air. They must go via FedEx Ground, UPS Ground, or DHL Ground.
PO Box deliveries are only available via USPS.
At this time, we do not ship lithium batteries to Puerto Rico. NiMH, NiCd, and Alkaline can be shipped.
📦 Important Notes
Double-check your shipping address! If an incorrect address is used and the order is returned, re-shipping costs are the buyer’s responsibility.
If a product is temporarily out of stock, we’ll notify you right away with the expected restock date—or issue a refund if you prefer.
💲 Currency & Pricing
All prices are shown in USD.
Orders shipped outside the USA may be subject to local taxes, customs fees, or import duties. These are the buyer’s responsibility.
⚡ At BatteryWeb, we’re committed to getting your batteries delivered quickly, safely, and affordably—so you’ll always have the power you need, when you need it.
Disclaimer
Disclaimer
⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.
🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.
🔹 Our products are generic replacement parts and are not affiliated with, endorsed by, or manufactured by the original equipment manufacturers (OEMs).
Volts & Amps
12 Volts | 7.5 Ah
Terminal Type
F2
Replacement Battery Set for Upsonic IP 6000 — SigmasTek SP12-7.5HR Compatible
Bring your Upsonic IP 6000 UPS back to peak performance with this comprehensive replacement battery set. Designed for reliability and strong short-term power delivery, this kit includes 20 SigmasTek SP12-7.5HR batteries engineered for UPS environments where consistent output and rapid discharge capability are required. This high-performance UPS battery pack is a great option for data centers, telecommunication closets, and emergency power installations seeking a long-lasting battery solution. Please remember to reuse your existing cables and mounting hardware when installing the new batteries.
Key Specifications
- Brand: SigmasTek
- Battery Model: SP12-7.5HR
- Voltage: 12 Volts
- Capacity: 7.5 Ah
- Quantity Included: 20 batteries
- Terminal Type: F2
- Design: High Rate Discharge Design
- Construction: Valve Regulated Spill Proof
- Features: Low Self-discharge; High Vibration Resistance
- Certifications: U.L. Recognized and CE Certified
- Condition: Brand New, Factory Fresh
- Warranty: 1 Year Warranty
- Compatibility Note: For Upsonic IP 6000 UPS units — use existing cables and hardware from original configuration
Benefits
These SigmasTek batteries are built for longevity and resilience. The valve-regulated, spill-proof construction reduces maintenance and improves safety, while the low self-discharge property ensures the batteries remain ready for action after long periods of standby. The high rate discharge design makes this pack a robust high-performance UPS battery option when short, high-current events occur. Rugged vibration resistance helps maintain integrity in mobile or noisy environments.
Recommended uses include Uninterruptible Power Supply units such as the Upsonic IP 6000, emergency power supply systems, and battery-powered tools that demand bursts of power. Each battery is factory fresh and tested by our technical staff to confirm it meets or exceeds OEM performance expectations, delivering a reliable replacement UPS battery that restores system uptime and protects critical loads.
With U.L. and CE recognition and a 1 year warranty, this replacement set balances safety, performance, and value — giving you a dependable long-lasting battery solution for your UPS.
Ready to upgrade your Upsonic IP 6000? Purchase this SigmasTek replacement battery set today to secure reliable backup power and fast shipping.
-
Voltage
-
Amp Hours
-
Terminal Type
-
Length (in.)
-
Width (in.)
-
Height (in.)
-
Weight (lb.)
-
Warranty
-
Type
-
Manufacturer
-
Brand Replacement
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.