Battery Care Guide
Battery Care Guide
Battery Usage and Maintenance Guidelines 🔋
Please read the following instructions carefully before using your new battery. Proper adherence will help ensure optimal performance and extended service life.
1. Cordless Phones, PDAs, and Power Tools (NiMH, NiCd, Lithium-Ion) 📱
Initial Charge
- Fully charge the battery overnight prior to first use.
Conditioning (First 2–6 Charge Cycles)
- Operate the device until the battery reaches approximately 20% capacity.
- Avoid premature recharging.
- Do not allow the battery to fully discharge during the initial cycles.
Post-Conditioning
- Recharge the battery only when necessary.
- These batteries are capable of approximately 500 charge cycles:
- Once daily → ~500 days
Twice daily → ~250 days
Note: Even a partial recharge is considered a full cycle.
2. Sealed Lead Acid (SLA) Batteries 💡
- No conditioning required.
- Maintain the battery in a fully charged state; avoid complete discharge.
- Capable of 300–400 charge cycles.
- Expected service life: 2–3 years, depending on usage conditions.
3. Laptop Batteries (Lithium-Ion) 💻
Initial Charge
- Fully charge the battery overnight prior to first use.
Conditioning (First 2–6 Charge Cycles)
- Charge fully, then discharge to approximately 20% capacity.
- Avoid complete discharge, as some devices may not detect a fully drained battery.
Post-Conditioning
- Minimize frequent plugging and unplugging.
- Allow the battery to discharge moderately at least once per month to maintain optimal performance.
- Occasional cycling is recommended to sustain battery health.
Professional Recommendation
Adhering to these guidelines will enhance battery longevity and ensure reliable performance.
For further assistance regarding your battery or order, our customer support team is available to provide guidance.
Delivery and Shipping
Delivery and Shipping
⚡ Everything You Need to Know About Shipping with BatteryWeb (USA)
We know reliable delivery matters when you need power fast. Here’s how BatteryWeb makes shipping easy across the USA:
🚚 Shipping & Delivery
Most orders ship next business day (some products like sealed lead acid may take a little longer).
Same-day shipping available if you order before 11:59 AM (delivery depends on the carrier).
We ship nationwide using FedEx, UPS, USPS, DHL, and regional ground carriers.
Shipping costs are calculated automatically at checkout based on weight, distance, and carrier.
Transit times shown are estimates only (business days, no weekends/holidays).
🌍 Shipping Restrictions
Lithium batteries cannot be shipped by USPS or air. They must go via FedEx Ground, UPS Ground, or DHL Ground.
PO Box deliveries are only available via USPS.
At this time, we do not ship lithium batteries to Puerto Rico. NiMH, NiCd, and Alkaline can be shipped.
📦 Important Notes
Double-check your shipping address! If an incorrect address is used and the order is returned, re-shipping costs are the buyer’s responsibility.
If a product is temporarily out of stock, we’ll notify you right away with the expected restock date—or issue a refund if you prefer.
💲 Currency & Pricing
All prices are shown in USD.
Orders shipped outside the USA may be subject to local taxes, customs fees, or import duties. These are the buyer’s responsibility.
⚡ At BatteryWeb, we’re committed to getting your batteries delivered quickly, safely, and affordably—so you’ll always have the power you need, when you need it.
Disclaimer
Disclaimer
⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.
🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.
🔹 Our products are generic replacement parts and are not affiliated with, endorsed by, or manufactured by the original equipment manufacturers (OEMs).
Volts & Amps
12 Volts | 7.5 Ah
Terminal Type
F2
SigmasTek SP12-7.5HR Replacement Battery Set for Upsonic STATION 140 UPS
Specifically matched for the Upsonic STATION 140 UPS, this replacement battery set uses SigmasTek SP12-7.5HR cells to provide consistent, reliable backup power when you need it most. These brand-new batteries are built for high-rate discharge applications and are an excellent choice for restoring runtime and performance to your UPS system. Compatibility and quality are prioritized to ensure smooth installation and dependable operation.
Key Specifications
- Brand: SigmasTek
- Model: SP12-7.5HR
- Voltage: 12 Volts
- Capacity: 7.5 AH (Amp-hours)
- Quantity: 4 batteries included
- Terminal Type: F2
- Design: High Rate Discharge Design
- Construction: Valve Regulated Spill Proof Construction
- Certifications: U.L. Recognized and CE Certified
- Features: Low Self-discharge, High Vibration Resistance
- Condition: Brand New, Factory Fresh
- Warranty: 1 Year Warranty
Benefits
These replacement batteries deliver a combination of durability, safety, and performance. The high-rate discharge design provides the necessary energy delivery during brief, intensive demand periods, making these batteries ideal as a high-performance UPS battery option for the Upsonic STATION 140. Low self-discharge helps maintain capacity during periods of inactivity, while valve-regulated, spill-proof construction reduces maintenance needs and enhances safety during installation and use.
High vibration resistance ensures mechanical stability in environments where movement or transport might otherwise stress battery internals. U.L. recognition and CE certification confirm that the batteries meet industry safety and performance standards. Each battery is factory-fresh and tested by experienced technicians to ensure it meets or exceeds OEM expectations, giving you a reliable, long-lasting battery investment.
Typical applications include Uninterruptible Power Supply (UPS) units like the Upsonic STATION 140, emergency power supply systems, and battery-powered tools that require dependable bursts of energy. Remember that installation requires reuse of the original cables and hardware from your UPS configuration to ensure proper connections and safe operation.
For product questions or purchasing assistance, call our customer support team at . In-stock items usually ship within 24 hours so you can get your UPS back to full protection quickly.
Purchase this high-performance, long-lasting replacement UPS battery set for the Upsonic STATION 140 today and protect your critical equipment with confidence.
-
Voltage
-
Amp Hours
-
Terminal Type
-
Length (in.)
-
Width (in.)
-
Height (in.)
-
Weight (lb.)
-
Warranty
-