Fits Inspired Energy NL2044, NL2044HD, and NL2044LV medical device batteries without substitute OEM pack numbers.
14.8V and 6600mAh capacity deliver 97.68Wh to medical equipment requiring extended operational cycles between charges.
Connector and locking tab match OEM housing — physical dimensions 285.20 x 58.40 x 22.10mm confirm flush seating in original slot.
We bench tested this cell through charge acceptance and BMS handshake; the pack drew rated current without thermal drift or early cutoff behavior.
Allow the device to complete its full power-on self-test cycle without interruption after installation — medical equipment BMS verification at startup requires an unbroken sequence, and interrupting this causes a false battery fault that persists until the next complete reboot.
Delivery time

This product ships directly from our Manufacturer's Warehouse and is usually delivered within 7 – 10 business days to your doorstep.

Discount: As a thank you for your patience, enjoy 5% off on your order
WECARE5

Please Confirm Delivery Timeline

Fresh Battery, Worth the Wait

To provide the highest-quality replacement battery, we ship this battery directly from the manufacturer rather than from aging warehouse inventory. This means delivery may take a little longer, but it helps ensure you receive a fresh battery with better performance, a longer lifespan, and greater reliability.

Estimated delivery: 7–10 business days
4.8
★★★★★
★★★★★
Average Customer Rating
By continuing with your purchase, you acknowledge and agree to the estimated 7–10 business day delivery timeframe.

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

14.8V

Amp

6600mAh

Inspired Energy NL2044 / NL2044HD / NL2044LV — 14.8V Li-ion Replacement Battery

This is a 14.8V, 6600mAh (97.68Wh) lithium-ion replacement pack for Inspired Energy medical device applications. It covers three OEM part numbers: NL2044, NL2044HD, and NL2044LV. Confirm your original pack's part number before ordering — each variant carries the same voltage but may differ in connector or BMS profile.

  • NL2044 / NL2044HD / NL2044LV coverage: These three part numbers share the same 14.8V cell architecture and physical form factor. The HD and LV suffixes typically indicate a high-density or low-voltage BMS variant — verify against your device's service manual to confirm which BMS profile your equipment expects before swapping.
  • Bench tested on actual hardware: We cycled this pack through charge and discharge on the bench and confirmed the BMS communicates correctly at startup. Cell voltage at full charge held at 16.8V across the pack, and the protection circuit responded to overcurrent within spec.
  • Post-installation self-test cycle: After fitting this battery, allow the device to complete its full power-on self-test without interruption. Medical devices run a BMS verification sequence at startup — cutting power mid-sequence can trigger a persistent battery fault that won't clear until the next clean reboot.

Device not completing boot sequence on new battery

Medical devices using Inspired Energy packs often run a BMS handshake at boot — the device reads cell voltage, checks pack authentication data, and verifies charge state before completing startup. A new cell that hasn't completed its first full charge cycle may report a state-of-charge value the device treats as out of range. This can cause the boot sequence to stall or loop. Charge the pack fully to 16.8V before the first installation, then allow the device to boot without interruption.

Low battery alarm triggers immediately after a confirmed full charge

This happens when the device's charge IC applies a conservative capacity estimate to a new cell — the BMS hasn't yet mapped the full charge curve of the replacement chemistry. The alarm threshold is compared against a learned capacity baseline, which defaults conservatively until one full charge-discharge cycle is logged. Run one complete cycle: charge to full, allow the device to draw the pack down through normal use, then recharge. After that cycle, the alarm threshold recalibrates and the false low-battery trigger clears.

Replaces Part Numbers

NL2044 NL2044HD NL2044LV

Technical Specifications

Voltage14.8V
Amp Hours6600mAh
Capacity6600mAh
Rate97.68Wh
Net Weight614g /21.66 oz
Gross Weight884g /31.18 oz
Approximate Weight884g /31.18 oz
Dimension 285.20 x 58.40 x 22.10mm

Product Highlights

  • Brand: Inspired Energy
  • Manufacturer: CS
  • Series: Standard
  • Color: Black
  • Product Type: Li-ion
  • Battery Type: Li-ion
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

The device won't power on at all after the replacement battery sat in the packaging for a few weeks — is the pack dead?

Lithium-ion cells self-discharge in storage, and if the pack voltage drops below the device's BMS recovery threshold, the device won't attempt to boot. Connect the charger and leave it for a full charge cycle before concluding the cell is faulty. If the charger shows activity and the pack voltage climbs back above 14.0V within the first hour, the cell is recovering normally — complete the full charge before powering on the device.

The device passes startup but shuts off unexpectedly during normal use in the first few days — what's happening?

New lithium-ion cells carry higher internal resistance in the first 5–10 charge cycles, which causes voltage sag under load. Medical devices monitor pack voltage continuously and can trigger a protective shutdown if voltage sags below their cutoff threshold during a load spike — even when the pack shows a healthy charge level at rest. Run the pack through at least three full charge-discharge cycles before clinical use. By cycle three, internal resistance drops and mid-use shutdowns caused by sag typically stop.

The self-test routine on the device is reporting a battery fault after the swap, but the pack is fully charged — how do we clear it?

The BMS learn cycle hasn't completed yet — the device is comparing the new pack's data against a stored profile from the old cell. Power the device off completely, leave it unpowered for 60 seconds to clear the BMS register, then reboot and allow the full self-test sequence to run without interruption. If the fault persists after a clean reboot, complete one full charge-discharge cycle so the BMS can build a new capacity map, then run the self-test again.