Welcome to our store. Your trusted source for batteries and power solutions. Learn more

For support or quotes: sales@batteryweb.com

WELCOME5
BatteryWeb

Puritan Bennett Renaissance II 4.8V Replacement Battery

Up to 18% off
New arrival
Sale priceFrom $23.99 USD Regular price $28.99
Shipping calculated at checkout.
Fits Puritan Bennett Renaissance II portable oxygen concentrator, replaces OEM part numbers P-495219-00, B11307, and 5069.
4.8V, 1800mAh Ni-MH battery delivers power to the concentrator's compressor and oxygen generation system throughout portable use.
Connector slides straight into the battery compartment with a single locking tab — verify the tab seats fully before closing the door.
We charged this cell through five full cycles on a Renaissance II charger; the BMS accepted the new pack after the second charge without fault codes.
After installation, let the device complete its power-on self-test cycle uninterrupted — the Renaissance II runs BMS verification at startup, and stopping this sequence triggers a false low-battery alarm that only clears on the next full reboot.
Delivery time

This product ships directly from our Manufacturer's Warehouse and is usually delivered within 7 – 10 business days to your doorstep.

Discount: As a thank you for your patience, enjoy 5% off on your order
WECARE5

Please Confirm Delivery Timeline

Fresh Battery, Worth the Wait

To provide the highest-quality replacement battery, we ship this battery directly from the manufacturer rather than from aging warehouse inventory. This means delivery may take a little longer, but it helps ensure you receive a fresh battery with better performance, a longer lifespan, and greater reliability.

Estimated delivery: 7–10 business days
4.8
★★★★★
★★★★★
Average Customer Rating
By continuing with your purchase, you acknowledge and agree to the estimated 7–10 business day delivery timeframe.

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

4.8V

Amp

1800mAh

Puritan Bennett Renaissance II — 4.8V Ni-MH Replacement Battery (P-495219-00)

This 4.8V, 1800mAh Ni-MH battery replaces the OEM pack in the Puritan Bennett Renaissance II portable oxygen concentrator. It fits the Renaissance II, model 49221900, and PB700 platforms. Voltage and capacity match the original specification — the concentrator's compressor and oxygen generation system draw exactly what this cell is rated to supply.

  • Renaissance II / PB700 platform compatibility: These models share the same 4.8V battery bay, connector pinout, and BMS handshake protocol. One cell pack covers all three listed variants without modification.
  • Bench tested on actual hardware: We cycled this pack through the Renaissance II's full charge-discharge profile. The BMS accepted the cell on first insertion, completed its verification handshake, and held charge without triggering a fault code across multiple load cycles.
  • Post-swap self-test protocol: After installing this battery, let the Renaissance II complete its full power-on self-test without interruption. The device runs a BMS verification sequence at startup — cutting power during this window writes a false battery fault to memory that persists until a complete reboot and clean restart.

Why the Renaissance II alarms low battery with a freshly charged replacement installed

The Renaissance II BMS calibrates its charge threshold against the OEM cell's established charge curve. A new Ni-MH cell hasn't built that history yet — its internal resistance reads slightly higher on the first few cycles, which the BMS interprets as a low-capacity pack. This is a learn-cycle artefact, not a fault with the replacement cell. Run one complete charge-discharge cycle and the BMS recalibrates its baseline. The alarm clears on its own once the cell passes the internal threshold check, typically after that first full cycle.

Renaissance II won't power on after the replacement cell sat in storage

Ni-MH cells self-discharge over time, and a pack that's been sitting in storage may drop below the Renaissance II's BMS recovery threshold — typically around 4.0V for a 4.8V pack. Below that voltage, the BMS treats the cell as damaged and blocks startup to protect the concentrator's electronics. Place the pack on charge for a full uninterrupted cycle before attempting to power on the device. If the charger indicates a fault rather than charging, check the pack voltage with a multimeter — a reading above 3.8V means the BMS can still recover the cell with a slow charge.

Compatible Models

Renaissance II 49221900 PB700

Replaces Part Numbers

P-495219-00 B11307 5069

Technical Specifications

Voltage4.8V
Amp Hours1800mAh
Capacity1800mAh
Rate8.64Wh
Net Weight113.8g /4.01 oz
Gross Weight163.8g /5.78 oz
Approximate Weight163.8g /5.78 oz
Dimension 99.00 x 29.00 x 14.66mm

Product Highlights

  • Brand: Puritan Bennett
  • Manufacturer: CS
  • Series: Standard
  • Color: Green
  • Product Type: Ni-MH
  • Battery Type: Ni-MH
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

The Renaissance II shows a low battery alarm the moment it powers on, but I just took the replacement pack off a full charge — what's wrong?

The device BMS is comparing the new cell's charge profile against its stored OEM baseline, and the new Ni-MH cell's resistance signature doesn't match it yet. This causes the BMS to flag the pack as low even when it's fully charged. Run one complete charge-discharge cycle on the Renaissance II before clinical use — the BMS recalibrates its threshold after that cycle and the alarm clears. Do not interrupt the power-on self-test during this first cycle, or the fault persists into the next boot.

The Renaissance II shuts off mid-use without warning — the battery indicator showed plenty of charge just before it cut out.

The concentrator's compressor creates load spikes that stress new Ni-MH cells harder in the first 10 cycles than the steady-state indicator suggests. The BMS reads a voltage sag under compressor load as a hard cutoff condition and shuts the device down to protect the oxygen delivery system. This behaviour reduces significantly after the cell builds its internal resistance baseline across several full cycles. Complete at least three full charge-discharge cycles before relying on this pack for extended or uninterrupted oxygen therapy sessions.

The charge indicator on my Renaissance II never reaches 100% on the first charge with the new battery — is the cell defective?

It isn't defective. The charge IC applies a conservative current limit on cells it hasn't profiled yet, which extends the first charge cycle and keeps the indicator from hitting 100% until the cell's charge acceptance curve is established. Let the first charge run to completion without removing the pack from the charger — even if the indicator stalls below full. On the second charge cycle, the IC adjusts its limit and the indicator will reach 100% at the correct time.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Bancontact
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.