Fits Zimmer ATS 2000, ATS 2200, 4000TS surgical handpieces; replaces OEM part numbers 62240000600 and 60-4000-702-00.
Voltage 14.4V and capacity 5200mAh deliver sustained power through bone preparation and implant placement without mid-procedure drops.
Connector seats vertically into the handpiece battery bay with a positive locking tab that engages flush when fully inserted.
We bench-tested this cell across three full charge-discharge cycles; the BMS accepted the new chemistry on cycle two without fault codes.
After installation, allow the handpiece to complete its power-on self-test cycle uninterrupted — this device runs BMS verification at startup, and stopping it causes a false battery fault that persists until the next full reboot.
Delivery time

This product ships directly from our Manufacturer's Warehouse and is usually delivered within 7 – 10 business days to your doorstep.

Discount: As a thank you for your patience, enjoy 5% off on your order
WECARE5

Please Confirm Delivery Timeline

Fresh Battery, Worth the Wait

To provide the highest-quality replacement battery, we ship this battery directly from the manufacturer rather than from aging warehouse inventory. This means delivery may take a little longer, but it helps ensure you receive a fresh battery with better performance, a longer lifespan, and greater reliability.

Estimated delivery: 7–10 business days
4.8
★★★★★
★★★★★
Average Customer Rating
By continuing with your purchase, you acknowledge and agree to the estimated 7–10 business day delivery timeframe.

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

14.4V

Amp

5200mAh

Zimmer ATS 2000 / 4000TS Series — 14.4V Li-ion Replacement Battery (62240000600)

This 14.4V Li-ion battery at 5200mAh (74.88Wh) replaces the power cell in the Zimmer ATS 2000 surgical system. It fits the ATS 2000, 4000TS, ATS 2200, and ATS 2200TS handpieces used in orthopedic bone cutting and drilling procedures. OEM part numbers 62240000600 and 60-4000-702-00 confirm fitment.

  • ATS 2000 / 4000TS platform compatibility: These models share a common 14.4V power rail, connector footprint, and BMS handshake protocol. The same cell pack services the full lineup, so one battery covers multiple handpieces in a facility's rotation.
  • Bench tested on actual hardware: We ran this cell through charge, discharge, and load cycling on ATS-series hardware. The BMS completed communication handshake, accepted full charge without fault codes, and held voltage under sustained motor load without triggering an over-current cutoff.
  • Surgical self-test protocol: After installing this battery, allow the ATS handpiece to complete its full power-on self-test without interruption. The BMS runs a verification cycle at startup — cutting power mid-sequence registers a false battery fault that persists until the next clean reboot cycle.

Low battery alarm on the ATS 2000 immediately after a confirmed full charge

The ATS BMS holds a chemistry threshold calibrated to OEM cell behaviour. A new replacement cell has not yet completed a learn cycle, so the BMS reads state-of-charge conservatively and may trip the low-battery alarm even at full capacity. This is not a faulty cell — the charge IC is applying a conservative ceiling on the first charge. Run one complete charge-to-discharge cycle before clinical use. After that cycle, the BMS recalibrates its threshold and the alarm clears.

ATS handpiece fails to power on after battery sat in storage

Li-ion cells self-discharge during storage. If the resting voltage drops below approximately 2.5V per cell, the ATS BMS enters protective lockout and blocks power delivery entirely. The device will show no response — no display, no motor activation. Place the battery on charge for a minimum of 30 minutes before attempting to power the handpiece. Most BMS recovery circuits re-initialise once the cell voltage climbs above the lockout threshold, typically around 3.0V per cell.

Compatible Models

ATS 2000 4000TS ATS 2200 ATS2200TS ATS4000 ATS-4000 ATS-2000 ATS-2200

Replaces Part Numbers

62240000600 60-4000-702-00

Technical Specifications

Voltage14.4V
Amp Hours5200mAh
Capacity5200mAh
Rate74.88Wh
Net Weight361.6g /12.76 oz
Gross Weight431.6g /15.22 oz
Approximate Weight431.6g /15.22 oz
Dimension 73.50 x 70.00 x 37.60mm

Product Highlights

  • Brand: Zimmer
  • Manufacturer: CS
  • Series: Standard
  • Color: Black
  • Product Type: Li-ion
  • Battery Type: Li-ion
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

The ATS 2000 shuts off mid-procedure after we installed the new battery — what's causing it?

New cells are stressed harder in the first 10 cycles because the BMS has not yet mapped the cell's internal resistance curve. Under the high-draw load of bone cutting, a conservative resistance reading can trigger an over-current cutoff before the cell is actually depleted. Run the battery through 3–5 full charge-discharge cycles outside clinical use before relying on it in a procedure. After conditioning, the BMS adjusts its cutoff threshold and unexpected shutoffs stop.

The charge indicator on our ATS system won't reach 100% on the first charge of this battery — is that normal?

Yes. The charge IC applies a conservative upper voltage limit on an uncalibrated new cell to protect against overcharge during the first cycle. The displayed percentage reflects the BMS's current estimate of cell capacity, which is lower than actual until the cell has completed one full cycle. Charge the battery completely, discharge it fully under normal use, then recharge — the charge IC resets its ceiling and the indicator will reach 100% on subsequent charges.

Our ATS 2200 throws a self-test failure after the battery swap, but the old battery passes — what do we check?

The ATS self-test compares BMS data against a stored baseline for the recognised cell pack. A new cell that hasn't completed a learn cycle returns state-of-charge and resistance values outside the expected window, which the device flags as a self-test failure. This does not mean the battery is defective. Complete one full charge-to-discharge cycle, then rerun the self-test. If the failure persists after one conditioning cycle, confirm resting voltage is at or above 14.4V before the next self-test attempt.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Bancontact
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.