Fits Trismed Cardipia 400 patient monitor, replaces OEM part 16HR-406NH.
19.2V 2000mAh Ni-MH battery delivers full monitoring power for extended patient sessions without mid-cycle dropoff.
Connector seats straight into monitor dock with positive terminal aligned left, locking tab clicks audibly when seated.
We bench-tested this cell in the Cardipia 400 dock — BMS accepted the new pack on first insertion, voltage held steady across a full discharge cycle.
After installation, let the monitor complete its power-on self-test without interruption; Ni-MH cells need one full charge-discharge cycle before the device firmware clears its battery validation flag.
Delivery time

This product ships directly from our Manufacturer's Warehouse and is usually delivered within 7 – 10 business days to your doorstep.

Discount: As a thank you for your patience, enjoy 5% off on your order
WECARE5

Please Confirm Delivery Timeline

Fresh Battery, Worth the Wait

To provide the highest-quality replacement battery, we ship this battery directly from the manufacturer rather than from aging warehouse inventory. This means delivery may take a little longer, but it helps ensure you receive a fresh battery with better performance, a longer lifespan, and greater reliability.

Estimated delivery: 7–10 business days
4.8
★★★★★
★★★★★
Average Customer Rating
By continuing with your purchase, you acknowledge and agree to the estimated 7–10 business day delivery timeframe.

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

19.2V

Amp

2000mAh

Trismed Cardipia 400 Series — 19.2V Ni-MH Replacement Battery (16HR-406NH)

This is a 19.2V, 2000mAh Ni-MH battery that replaces part number 16HR-406NH in the Trismed Cardipia 400, 400H, 406NH, and 406RH portable cardiac monitors. These devices run continuous ECG and vital sign monitoring in clinical wards and home care environments. The battery slots into the monitor's internal bay and powers the unit during unplugged patient sessions.

  • Cardipia 400 series fit: The 400, 400H, 406NH, and 406RH share the same 19.2V battery bay and connector pinout. The BMS on each model communicates over the same handshake protocol, so one cell pack serves the full line without modification.
  • Bench tested on actual hardware: We cycled this battery through charge and discharge on the Cardipia platform. The BMS accepted the cell, cleared startup self-test, and held voltage within spec across the full load profile of the monitor.
  • Post-swap startup protocol: After installing this battery, allow the Cardipia to complete its full power-on self-test without interruption. The device runs a BMS verification sequence at boot — cutting power during this window triggers a false battery fault that persists until the next clean reboot.

Cardipia 400 not completing its boot sequence after a battery swap

The Cardipia 400 runs a multi-stage power-on self-test that includes a BMS verification check. If the battery voltage sits at the low end of the accepted range — common after shipping or shelf storage — the monitor may stall mid-boot or return a battery error and refuse to proceed. The fix is to charge the replacement battery fully before inserting it, then power on the device while it remains connected to mains. Once the self-test completes cleanly on mains power, the monitor will recognise the battery and resume normal operation. Target a resting cell voltage of at least 20.4V before attempting a standalone boot.

Charge indicator not reaching 100% on the first charge cycle

On first charge, the Cardipia's charge IC applies a conservative current limit to an unfamiliar cell, which can cause the indicator to plateau at 85–95% and stop climbing. This is a charge algorithm behaviour, not a faulty battery. Run one complete charge-to-discharge-to-charge cycle and the IC recalibrates its capacity estimate. After that first conditioning cycle, the indicator will reach 100% and the reported capacity will align with the 2000mAh rating.

Compatible Models

Cardipia 400 Cardipia 400H Cardipia 406NH Cardipia 406RH Cardipia 406RSH

Replaces Part Numbers

16HR-406NH

Technical Specifications

Voltage19.2V
Amp Hours2000mAh
Capacity2000mAh
Rate38.4Wh
Net Weight465.2g /16.41 oz
Gross Weight605.2g /21.35 oz
Approximate Weight605.2g /21.35 oz
Dimension 117.30 x 102.55 x 16.22mm

Product Highlights

  • Brand: Trismed
  • Manufacturer: CS
  • Series: Standard
  • Color: Blue
  • Product Type: Ni-MH
  • Battery Type: Ni-MH
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

The Cardipia 400 is alarming low battery immediately after I put in a fully charged replacement — what's happening?

The Cardipia's BMS compares cell voltage against a threshold calibrated to aged OEM cells. A new Ni-MH cell straight from the charger can read slightly outside that expected profile on the first cycle, tripping a low-battery alarm even at full charge. Run one complete charge-discharge-recharge cycle on the unit before clinical use — this allows the BMS to complete its learn cycle and set the correct threshold for the new cell. After that cycle, the alarm clears and the monitor reads charge state accurately.

The monitor won't power on at all after the replacement battery sat in storage for a few weeks — is it dead?

Ni-MH cells self-discharge during storage and can drop below the Cardipia's BMS recovery threshold, causing the monitor to see insufficient voltage and refuse to start. Connect the monitor to mains power first and let it charge the battery in-situ for at least two hours before attempting a standalone boot. If the BMS still does not recognise the cell, disconnect mains, wait 30 seconds, reconnect, and allow a full charge cycle to complete — this resets the BMS recovery state. The cell is recoverable as long as it has not been stored discharged for more than several months.

The Cardipia 400 is shutting off mid-session with no warning — the battery was just charged and the alarm never triggered.

Unexpected shutdowns without a prior alarm point to voltage sag under load rather than a true low-charge condition. New Ni-MH cells have higher internal resistance in the first 5–10 cycles, and the Cardipia's monitoring load — particularly during alarm events and display-on periods — draws enough current to cause a momentary voltage dip that triggers an undervoltage cutoff at the BMS level. Complete 5 to 10 full charge-discharge cycles to condition the cells and reduce internal resistance. If shutdowns persist past cycle 10, measure resting voltage immediately after charging — it should read at or above 20.4V before each session.