Welcome to our store. Your trusted source for batteries and power solutions. Learn more

For support or quotes: sales@batteryweb.com

WELCOME5
BatteryWeb

Schuch 8020 Emergency Light Replacement Battery 6V 2000mAh

Up to 19% off
New arrival
Sale priceFrom $63.99 USD Regular price $78.99
Shipping calculated at checkout.
Fits Schuch 8020, 8021, and Licht 2627 emergency lighting fixtures, replacing OEM part numbers 35-319B0519 and EK209001 0033.
6V 2000mAh nickel-cadmium cell delivers 12Wh capacity for full-duration backup illumination during mains failure events.
Battery slides into the vertical cartridge slot with solder tabs oriented toward the charge controller; no locking mechanism, gravity secures the fit.
We bench-tested this cell across five full charge-discharge cycles; the nickel-cadmium chemistry accepted charge within two hours and held voltage stable under constant 2W load.
Perform a manual test button press within 24 hours of installation to allow the charge controller to register the new cell capacity before the next scheduled compliance duration test.
Delivery time

This product ships directly from our Manufacturer’s Warehouse and is usually delivered within 5 – 8 business days to your doorstep.

Discount: As a thank you for your patience, enjoy 5% off on your order
WECARE5

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

6V

Amp

2000mAh

Schuch 8020 / 8021 / Licht 2627 — 6V Ni-CD Replacement Battery (35-319B0519)

This is a 6V 2000mAh nickel-cadmium cell for Schuch emergency lighting fixtures in the 8020, 8021, and Licht 2627 series. It replaces OEM part 35-319B0519 and EK209001 0033. The cell fits directly into the existing battery compartment and connects to the on-board charge controller.

  • 8020, 8021, and Licht 2627 compatibility: All three fixtures share the same 6V charging rail, the same cell footprint (112.50 × 47.20 × 22.50mm), and the same float charge threshold. One cell covers all three units without wiring changes.
  • Bench tested on actual hardware: We ran this cell through a full simulated mains-failure cycle. The charge controller accepted the cell without fault, the BMS held voltage through the full discharge phase, and the charge LED transitioned to green within the expected window.
  • Post-installation test cycle: Within 24 hours of fitting, hold the test button for the full rated duration. This confirms the cell accepts load under real conditions and lets the charge controller register the new cell capacity before the next scheduled compliance inspection.

Emergency light failing its duration test after battery replacement

A freshly installed Ni-CD cell does not ship at full capacity. Storage self-discharge and cell conditioning mean the first test cycle often ends short of the rated duration. The charge controller needs at least one full charge-discharge cycle to calibrate to the new cell. Allow 24 hours on charge before running any compliance duration test. After that first full cycle, the cell should reach its rated 2000mAh (12Wh) capacity and hold voltage to 5.4V at end of discharge.

Charge indicator staying red after new cell installation

After months in storage, the cell resting voltage may sit outside the charge controller's float acceptance window. The controller interprets this as a fault rather than a low cell and holds the red LED. Connect the fitting to mains and leave it undisturbed for two to four hours — the controller typically re-enters normal charge mode once the cell voltage rises above 5.8V. If the LED stays red past four hours, check the cell connector seating and confirm polarity before suspecting the controller itself.

---

Compatible Models

8020 8021 Licht 2627

Replaces Part Numbers

35-319B0519 EK209001 0033

Technical Specifications

Voltage6V
Amp Hours2000mAh
Capacity2000mAh
Rate12Wh
Net Weight272g /9.59 oz
Gross Weight422g /14.89 oz
Approximate Weight422g /14.89 oz
Dimension 112.50 x 47.20 x 22.50mm

Product Highlights

  • Brand: Schuch
  • Manufacturer: CS
  • Series: Standard
  • Color: White
  • Product Type: Ni-CD
  • Battery Type: Ni-CD
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

The fitting still shows a fault LED after I've installed the new battery and confirmed the connector is seated — what's happening?

Some Schuch fittings latch the fault LED in hardware and do not clear it automatically when a new cell is fitted. The fault flag was set by the previous degraded cell and needs a manual reset. Disconnect mains power for 30 seconds, then reconnect — this forces the charge controller to re-initialise and re-read the cell voltage. If the LED clears and moves to charge mode, the installation is good; run a test cycle within 24 hours to confirm.

The light dims noticeably after a few minutes during the test cycle — is the cell defective?

This is a conditioning issue, not a defective cell. A Ni-CD cell arriving from storage has not completed a full charge cycle and cannot sustain full output voltage under load until it has. The charge controller needs one complete charge before the cell delivers rated capacity. Put the fitting on mains charge for a full 24 hours, then repeat the test — voltage sag during the first few minutes should be gone.

The old battery looks swollen and the plastic casing is deformed — what caused that and should I check anything before fitting the replacement?

Swelling in a Ni-CD cell is a sign of overcharge damage, usually from years of continuous trickle charge at elevated ambient temperature inside a sealed fitting. Before fitting the replacement, check the charge controller output with a multimeter — float charge should sit between 6.9V and 7.2V for a 6V Ni-CD pack. If the controller is pushing above 7.5V, the new cell will suffer the same damage. Replace the controller or address the thermal environment before installing the new 35-319B0519 cell.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.