Ledlenser X21R.2 Replacement Battery 9.6V 5000mAh LiFePO4
Check that your old battery model number and device model to match our description. This makes sure they work together.
We ship your order same day if you buy it before 4 PM EST.
Ledlenser X21R.2 Replacement Battery 9.6V 5000mAh LiFePO4 - is backordered and will ship as soon as it is back in stock.
Let customers speak for us
Send Your Battery Photo
Expert Technician Help
Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.
POST YOUR BATTERY IMAGE
Product & Solutions Expert
✉ sales@batteryweb.com
Battery Care Tips
Battery Care Tips
🔹 Getting Started
Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.
🔹 Keep It Healthy
Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.
Delivery and Shipping
Delivery and Shipping
🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.
Disclaimer
Disclaimer
⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.
🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.
Ledlenser X21R.2 Replacement Battery 9.6V 5000mAh LiFePO4 - is backordered and will ship as soon as it is back in stock.
Voltage
9.6V
Amp
5000mAh
Ledlenser X21R.2 — 9.6V LiFePO4 Replacement Battery (SP7712)
This is a 9.6V LiFePO4 replacement battery rated at 5000mAh (48Wh) for the Ledlenser X21R.2 rechargeable flashlight. It replaces OEM part SP7712 and restores full output to the X21R.2's LED driver circuit. LiFePO4 chemistry holds a flatter discharge curve than standard lithium-ion, which keeps the driver operating in its target voltage window longer.
- X21R.2 platform fit: The X21R.2 uses a multi-cell LiFePO4 pack at 9.6V nominal — a voltage rail specific to this light's driver board. Substituting a different chemistry or voltage causes the driver to operate outside its regulation range, which trips brownout protection and steps down output prematurely.
- Bench tested on actual hardware: We cycled this pack through the X21R.2's charge circuit and confirmed the BMS accepted full charge termination correctly. The protection circuit tripped at the expected low-voltage cutoff under high-current draw in turbo mode, with no false shutdowns on standard output.
- Multi-cell replacement rule: The X21R.2 pack is a matched multi-cell assembly. If you source a replacement, do not mix it with any remaining original cells from a degraded pack. Mismatched cells under high-draw turbo mode cause the weaker cell to collapse first, creating an imbalance the BMS cannot correct mid-draw.
Why the X21R.2 steps down output before the battery indicator reads low
The X21R.2 driver uses brownout protection to reduce output when pack voltage sags under load — even when the indicator still shows charge remaining. LiFePO4 cells have a flat discharge curve, so the indicator reads full until voltage drops sharply near the end. Under turbo mode, the high current draw causes a momentary sag that triggers the driver to step down before the cell is truly depleted. Switching to a lower output mode lets the pack recover voltage and resume normal regulated output.
Turbo mode runtime significantly shorter than standard — what's happening
Turbo mode on the X21R.2 draws five to ten times the current of standard mode, pulling the 9.6V pack into voltage sag far faster. The driver's thermal and brownout protection will step down output once the pack can no longer sustain the required current delivery. A degraded original battery accelerates this effect because aged cells have higher internal resistance, which amplifies voltage sag under the same load. If turbo runtime dropped sharply over time, internal resistance on the original pack has likely risen — this replacement pack restores rated capacity and lower internal resistance.
Compatible Models
Replaces Part Numbers
Technical Specifications
Product Highlights
- Brand: Ledlenser
- Manufacturer: CS
- Series: Standard
- Color: Blue
- Product Type: LiFePO4
- Battery Type: LiFePO4
- Warranty: 12 Months
- Bulk Orders: sales@batteryweb.com
Frequently Asked Questions
My X21R.2 is dimming on turbo even though the battery indicator still shows full — is the battery failing?
This is brownout protection stepping in, not a faulty indicator. Under turbo mode's high current draw, the pack voltage sags enough to trigger the driver to reduce output — even when remaining capacity is still high. LiFePO4's flat discharge curve means the indicator won't drop noticeably until the very end of discharge. Switch to standard mode to let the pack voltage recover, or replace the battery if this happens early in a charge cycle.
One section of my X21R.2 battery pack is getting noticeably warmer than the rest during charging — what causes that?
Uneven heat during charging points to cell imbalance inside the pack — one or more cells have drifted out of matched capacity with the rest. This happens when cells age at different rates or when a partial replacement was made with a non-matched cell. The hotter cell is being pushed harder by the charger to reach the same voltage as the others. Replace the full pack with a single matched assembly like this one — do not mix the new pack with any remaining old cells.
My X21R.2 won't hold a charge after sitting unused for several months — is the battery recoverable?
LiFePO4 cells self-discharge slowly, but a pack left fully depleted for months can drop below the BMS's recovery threshold. Once cell voltage falls below roughly 2.5V per cell, the BMS may block charging entirely as a protection measure. Place the flashlight on charge for at least 30 minutes — some chargers apply a trickle current that can recover a borderline pack. If the charge indicator never activates and the pack remains cold, the cells have discharged past recovery and the pack needs replacing.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Related Products
Engineered for Performance. Built to Last.
Check out our top-rated selection of reliable products built to last. We offer high-quality options that deliver consistent performance for all your needs.