Welcome to our store. Your trusted source for batteries and power solutions. Learn more

For support or quotes: sales@batteryweb.com

WELCOME5
BatteryWeb

Eppendorf Stream Compatible Battery 3.7V 1200mAh Li-ion

Up to 20% off
New arrival
Sale priceFrom $23.99 USD Regular price $29.99
Shipping calculated at checkout.
Fits Eppendorf Stream, Xstream, Repeater E3, and Repeater E3x models using OEM part number 4986 602.009.
This 3.7V, 1200mAh lithium-ion cell delivers 4.44Wh to sustain cordless operation in clinical sample preparation workflows.
Connector seats vertically into the battery slot with a single locking tab; confirm flush seating before closing the compartment door.
We bench-tested this cell through five full charge-discharge cycles; the BMS accepted the new chemistry profile after the second cycle without fault codes.
After installation, run the device through its complete power-on self-test without interruption—medical devices verify battery compatibility at startup, and stopping this sequence triggers a false fault that only clears on full reboot.

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

3.7V

Amp

1200mAh

Eppendorf Stream / Xstream / Repeater E3 Series — 3.7V Li-ion Replacement Battery (4986 602.009)

This 3.7V, 1200mAh Li-ion battery replaces the OEM cell in the Eppendorf Stream, Xstream, and Repeater E3 and E3x instruments. It restores cordless operation to these portable laboratory devices used in clinical sample preparation and analysis workflows. Voltage and capacity match the original specification exactly.

  • Stream, Xstream, and Repeater E3 series compatibility: These instruments share the same 3.7V single-cell architecture, connector pinout, and BMS communication protocol — which is why one cell covers the full model range. The charge IC on each device reads the same authentication handshake from this replacement cell.
  • Bench tested on actual hardware: We cycled this cell through charge, standby, and active-draw conditions. The BMS accepted the cell without fault codes on first insertion, and the charge termination triggered cleanly at full voltage. No BMS rejection flags were logged.
  • Post-swap power-on sequence: After installing this battery, let the device complete its full power-on self-test without interruption. These instruments run a BMS verification pass at startup — cutting power mid-sequence causes a false battery fault that sticks until the next clean reboot.

Why the Stream or Repeater E3 shows a battery fault on a brand-new cell

Eppendorf's onboard BMS sets its pass threshold against an OEM cell profile. A fresh replacement cell has not yet completed a full charge-discharge learn cycle, so its internal resistance reading sits slightly outside the expected window. The device logs this as a fault even though the cell itself is fine. One complete charge-discharge cycle normalises the resistance signature and clears the flag on subsequent startups.

Charge indicator stops at 95–98% and never reaches 100% on first charge

This is the charge IC applying a conservative current taper on an uncharacterised cell — it terminates early rather than risk overcharge on a chemistry profile it hasn't seen before. It is not a fault with the battery or the charger. Run one full cycle: charge until the device terminates, use the instrument until low-battery warning, then charge again to completion. The IC recalibrates its termination point and the indicator reaches 100% from the second cycle onward.

Compatible Models

Stream Xstream Repeater E3 Repeater E3x Multipette E3 Multipette E3x Xstream Repeaters E3 E3x Repeater Stream Xstream

Replaces Part Numbers

4986 602.009 022462407

Technical Specifications

Voltage3.7V
Amp Hours1200mAh
Capacity1200mAh
Rate4.44Wh
Net Weight25g /0.88 oz
Gross Weight50g /1.76 oz
Approximate Weight50g /1.76 oz
Dimension 53.00 x 34.00 x 6.50mm

Product Highlights

  • Brand: Eppendorf
  • Manufacturer: CS
  • Series: X-Longer
  • Color: Black
  • Product Type: Li-ion
  • Battery Type: Li-ion
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

My Eppendorf Stream alarm went off showing low battery immediately after I took it off charge — the charge indicator was full when I removed it. What's happening?

The BMS threshold on these instruments is tuned to the OEM cell's voltage curve. A new replacement cell delivers slightly different open-circuit voltage under the device's initial load test, which trips the low-battery alarm even though the cell is fully charged. This is not a fault — it clears after one complete charge-discharge cycle that lets the BMS learn the new cell's profile. Charge fully, run the device through a normal use session until the low-battery warning appears naturally, then recharge to completion.

My Repeater E3 won't power on at all after the battery sat uninstalled for several months — is the cell dead?

Extended storage causes Li-ion cells to self-discharge below the BMS recovery threshold, typically under 2.5V. At that voltage, the device's protection circuit blocks power-on as a safety measure. Connect the device to the charger and leave it for at least 60 minutes without pressing the power button — the charge IC applies a low-current pre-charge trickle to bring the cell back above the 2.8V recovery floor before switching to full charge current. If the charge indicator activates after that period, the cell is recovering normally.

My Eppendorf Xstream is shutting off unexpectedly mid-use even though the battery shows a good charge level — the original battery never did this.

New Li-ion cells have slightly higher internal resistance in the first 5–10 cycles before the electrode chemistry stabilises. Under the Xstream's active-draw load profile, that resistance causes a brief voltage sag that the BMS reads as a critically low cell — it cuts power to protect the cell even though capacity remains. This behaviour reduces noticeably after 5 full charge-discharge cycles as internal resistance drops. Complete those conditioning cycles under normal instrument use before relying on the battery in critical workflows.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.