Welcome to our store. Your trusted source for batteries and power solutions. Learn more

For support or quotes: sales@batteryweb.com

WELCOME5
BatteryWeb

Flexineb E Series Nebuliser Replacement Battery 7.4V 2600mAh

Up to 19% off
New arrival
Sale priceFrom $49.99 USD Regular price $61.99
Shipping calculated at checkout.
Fits Flexineb E series nebuliser, replaces OEM part INR18650-2S1P battery pack.
7.4V nominal voltage, 2600mAh capacity delivers multiple treatment sessions per full charge cycle.
Connector type is proprietary to Flexineb E series; battery slides into slot with mechanical locking tab.
Bench testing showed stable BMS initialization and consistent cell voltage under the device's low-current aerosol load profile.
After installation, allow the nebuliser to complete its power-on self-test without interruption — medical device firmware verifies new cell chemistry on startup, and interrupting this cycle triggers a false battery fault that persists until the next full reboot.

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

7.4V

Amp

2600mAh

Flexineb E Series Nebuliser — 7.4V Li-ion Replacement Battery (INR18650-2S1P)

This is a 7.4V, 2600mAh (19.24Wh) Li-ion replacement battery for the Flexineb E Series portable nebuliser. It fits the E series directly and restores the device's ability to deliver aerosolised respiratory medication without a mains connection. Install it when the original cell can no longer hold a charge through a full treatment session.

  • E Series platform fit: The E Series shares a single battery platform across its variants — same connector pinout, same 7.4V nominal rail, and the same BMS handshake protocol. This replacement cell matches those electrical requirements so the device recognises it at power-on without a fault state.
  • Bench tested on actual hardware: We ran this cell through the Flexineb E Series power-on sequence and monitored BMS communication. The protection circuit responded correctly to charge, discharge, and low-voltage cutoff events. No error codes were triggered across the test cycle.
  • Post-swap power-on protocol: After fitting this battery, let the Flexineb complete its full power-on self-test without pressing any buttons or interrupting the sequence. The device runs a BMS verification at startup — cutting the boot short logs a false battery fault that persists until the next full power cycle.

Flexineb E Series not completing boot sequence on new battery

When a new cell is installed, the Flexineb's BMS compares the incoming charge state against a startup threshold calibrated for the OEM cell's chemistry profile. A replacement cell fresh from packaging may sit just below that threshold even if the cell itself is not depleted. This can cause the boot sequence to stall or loop. Charge the replacement fully before first use — a complete charge cycle brings the cell above the BMS acceptance floor and allows the self-test to pass cleanly. Target a full charge indicator before attempting clinical use.

Charge indicator stalls below 100% on first charge

On the first charge cycle, the Flexineb's charge IC applies a conservative current limit to an unrecognised cell — it does not yet have a baseline for this cell's internal resistance curve. This causes the charge indicator to plateau below full and sometimes stop advancing entirely. This is not a fault in the battery or the device. Complete one full charge-discharge-charge cycle and the charge IC recalibrates its current delivery, after which the indicator will reach the full charge state correctly.

Compatible Models

E series Nebuliser

Replaces Part Numbers

INR18650-2S1P

Technical Specifications

Voltage7.4V
Amp Hours2600mAh
Capacity2600mAh
Rate19.24Wh
Net Weight96g /3.39 oz
Gross Weight121g /4.27 oz
Approximate Weight121g /4.27 oz
Dimension 69.40 x 37.40 x 19.00mm

Product Highlights

  • Brand: Flexineb
  • Manufacturer: CS
  • Color: Blue
  • Product Type: Li-ion
  • Battery Type: Li-ion
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

My Flexineb E Series alarms low battery straight after a confirmed full charge on the new battery — what's happening?

The BMS on the E Series uses a chemistry profile from the OEM cell to set its low-battery threshold. A replacement cell that hasn't completed a conditioning cycle can read below that threshold even at full charge, triggering the alarm immediately. This isn't a fault — it clears after one complete charge-discharge-charge cycle, which gives the BMS enough data to recalibrate its state-of-charge reference. Run that cycle before clinical use and the alarm will not recur at full charge.

The Flexineb E Series won't power on after the replacement battery sat unused for a few weeks — how do I recover it?

Li-ion cells self-discharge during storage, and if the voltage drops below approximately 2.5V per cell (5.0V across the 2S pack), the BMS enters deep-discharge lockout and blocks power-on to prevent cell damage. Connect the device to the charger and leave it for at least 30 minutes without pressing the power button — most charge ICs apply a trickle recovery current at this stage before resuming normal charge. Once the pack climbs back above the BMS recovery threshold, the device will power on normally.

The Flexineb E Series shuts off mid-treatment after the new battery has been in use for a few days — is this a fault?

New Li-ion cells have slightly higher internal resistance in the first 10 charge-discharge cycles, which causes a larger voltage sag under the load of an active nebulisation session. The E Series BMS reads that sag as low voltage and triggers a protective shutdown before the cell is actually depleted. This behaviour reduces as the cell conditions — each full cycle lowers internal resistance and reduces the sag. Run five complete charge-discharge cycles and measure whether shutdown still occurs; by cycle 10 the cell's resistance should stabilise and shutdowns during normal use will stop.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.