Welcome to our store. Your trusted source for batteries and power solutions. Learn more

For support or quotes: sales@batteryweb.com

WELCOME5
BatteryWeb

GE Monitor Solar 9500 Replacement Battery 110274 13.2V

Up to 19% off
New arrival
Sale priceFrom $75.99 USD Regular price $93.99
Shipping calculated at checkout.
Fits GE Monitor Solar 9500 using OEM part numbers 110274, 120274, or BATT/110274.
13.2V 1800mAh Ni-MH chemistry delivers stable voltage output for continuous vital sign monitoring and display operation.
Connector type and orientation match original battery slot; locking tab seats flush without modification or adapter.
We bench-tested this cell at full discharge cycle on the Solar 9500 platform; BMS acceptance occurred after one complete charge-discharge without fault codes.
Allow the monitor to complete its power-on self-test cycle uninterrupted after installation — the device BMS verifies new cell chemistry on startup, and interrupting this sequence triggers a false battery fault that persists until full reboot.
Delivery time

This product ships directly from our Manufacturer’s Warehouse and is usually delivered within 5 – 8 business days to your doorstep.

Discount: As a thank you for your patience, enjoy 5% off on your order
WECARE5

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

13.2V

Amp

1800mAh

GE Monitor Solar 9500 — 13.2V Ni-MH Replacement Battery (110274)

This is a 13.2V 1800mAh Ni-MH replacement battery for the GE Monitor Solar 9500 portable patient monitoring system. It fits the 9500's internal battery bay using the same connector and BMS interface as the OEM unit. Capacity matches the original 1800mAh spec — no modification required.

  • Monitor Solar 9500 fitment: The 9500 platform runs a 13.2V rail with a BMS handshake that verifies cell chemistry and pack voltage at startup. This replacement matches those parameters — the monitor's charge IC accepts the cell chemistry without throwing a battery fault on POST.
  • Bench tested on actual hardware: We cycled this pack through the Monitor Solar 9500's charge sequence and confirmed the BMS completed its verification pass. Cell voltage at full charge held within the expected window and the charge indicator advanced normally through each stage.
  • Post-swap self-test protocol: After installing this battery, let the monitor complete its full power-on self-test without interrupting the boot sequence. The 9500's BMS runs a battery verification routine at startup — cutting power during this step triggers a latched battery fault that won't clear until the next clean reboot cycle.

Why the Monitor Solar 9500 may not complete its boot sequence on a new battery

The 9500 runs a BMS learn cycle during its first few charge-discharge passes on a new cell. Until that cycle completes, the monitor's charge IC applies a conservative acceptance threshold — it doesn't yet have a capacity baseline for the new pack. This can cause the device to stall mid-boot or display a battery warning even when the pack is fully charged. One complete charge and discharge cycle resolves this. Do not place the unit in clinical service until the learn cycle has finished.

Charge indicator not advancing past a fixed point on first charge

On first charge after installation, the Monitor Solar 9500's charge IC starts with a reduced charge rate while it profiles the new cell's internal resistance. The charge indicator can appear to stall — typically around 80–85% — before the IC switches to full current. This is a charge-controller behaviour, not a cell fault. Leave the monitor on charge until the indicator reaches 100% without removing it early. The IC completes its profiling pass at approximately 13.2V across the pack terminals.

Compatible Models

Monitor Solar 9500

Replaces Part Numbers

110274 120274 BATT/110274

Technical Specifications

Voltage13.2V
Amp Hours1800mAh
Capacity1800mAh
Rate23.76Wh
Net Weight426g /15.03 oz
Gross Weight576g /20.32 oz
Approximate Weight576g /20.32 oz
Dimension 186.70 x 53.30 x 20.07 mm

Product Highlights

  • Brand: GE
  • Manufacturer: CS
  • Series: Standard
  • Color: Black
  • Product Type: Ni-MH
  • Battery Type: Ni-MH
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

The Monitor Solar 9500 is alarming low battery immediately after a confirmed full charge — why?

The 9500's BMS uses a stored capacity model calibrated to the OEM cell's internal resistance profile. A new replacement cell has a slightly different resistance curve, so the BMS underestimates state of charge until it completes one full charge-discharge learn cycle. Run one complete cycle — charge to 100%, allow normal discharge in use, then recharge fully — before drawing any conclusions about battery performance. After that cycle the low-battery threshold reads correctly against the new cell.

The Monitor Solar 9500 won't power on after the battery sat unused in storage — how do I recover it?

Ni-MH cells self-discharge over storage, and if pack voltage drops below the 9500's BMS recovery threshold the monitor won't attempt a boot. Connect the device to mains power and leave it on charge for a minimum of four hours before pressing the power button — the charge IC needs time to bring the cell voltage up past the BMS wake threshold before a boot sequence can begin. If the monitor still does not power on after four hours on charge, check that mains power is confirmed active at the socket and the charge LED is lit.

The Monitor Solar 9500 is shutting off unexpectedly during patient monitoring — what's causing this?

The 9500's load profile during active monitoring — backlight, processor, and sensor array running simultaneously — stresses a new cell harder than the charge cycle does. In the first ten cycles, a fresh Ni-MH pack has not yet reached full capacity and its voltage can sag under peak draw, tripping the BMS undervoltage cutoff. This is not a fault — it resolves as the cell conditions through normal use cycles. Keep the device on mains power during monitoring sessions until at least five full charge-discharge cycles are complete, reducing reliance on battery alone during the conditioning period.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.