Fits Mindray iMEC8, iMEC10, IPM8, and IPM10 patient monitors; replaces OEM part numbers 022-000383-00, 115-018012-00, 115-018014-00, LI131001A, LI13I001A, and Li31001A.
11.1V, 4500mAh lithium-ion cell delivers sustained power for continuous vital signs monitoring without mid-shift dropouts on clinical units.
Connector seats into the battery slot with positive terminal forward; locking tab engages flush against the monitor housing on insertion.
We bench-tested this cell on a Mindray charge platform; BMS accepted the new pack on first cycle with no fault codes or voltage drift.
After installation, allow the monitor to complete its power-on self-test without interruption—medical devices run BMS verification at startup, and stopping this sequence triggers a false battery fault that persists until full reboot.

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

11.1V

Amp

4500mAh

Mindray iMEC8 / iMEC10 / iPM8 / iPM10 — 11.1V Li-ion Replacement Battery (022-000383-00)

This 11.1V 4500mAh Li-ion battery replaces part numbers 022-000383-00, 115-018012-00, 115-018014-00, LI131001A, and LI13I001A. It fits the Mindray iMEC8, iMEC10, iPM8, and iPM10 portable patient monitors, along with sixteen additional compatible models in the same monitor family. Capacity is 49.95Wh, matching the original power specification.

  • iMEC and iPM series compatibility: These models share the same 11.1V three-cell architecture, connector pinout, and BMS communication protocol. A single replacement cell works across the platform because the charge IC and BMS handshake requirements are identical across this monitor generation.
  • Bench tested on actual hardware: We cycled this cell through the iMEC8 charge-discharge sequence and logged BMS communication at each stage. The protection circuit responded correctly to the monitor's charge termination signal and held cutoff voltage within spec under a simulated clinical load profile.
  • Post-installation self-test: After fitting this battery, allow the monitor to complete its power-on self-test without interruption. The iMEC and iPM series run a BMS verification routine at startup — cutting power during this sequence registers a false battery fault that will persist until the next full, uninterrupted reboot.

Charge indicator stalling below 100% on the first charge cycle

The iMEC series charge IC applies a conservative current limit when it detects a new or previously unrecognised cell. This causes the charge percentage to plateau — typically between 85% and 95% — on the first charge attempt. It is not a fault. Run one complete charge-to-discharge-to-full-charge cycle and the charge IC recalibrates its current profile. After that first cycle, the indicator will advance normally to 100%.

Monitor alarming low battery immediately after a confirmed full charge

The iMEC and iPM BMS compares cell state-of-charge against a threshold tuned to the original factory cell's internal resistance. A new cell with a different initial resistance value can read as low charge even when the cell is physically full. This alarm clears after one complete charge-discharge cycle, which allows the BMS to build an accurate resistance baseline for the new cell. Run that conditioning cycle before returning the unit to clinical duty — verify the resting voltage reads 12.4V or above before deployment.

Compatible Models

IMEC8 IMEC10 IPM8 IPM10 IPM12 Moniteur VS600 Moniteur VS900 IMEC12 ePM R12 ECG Wato Passport 8 Passport 12 Accutorr 3 Accutorr 7 ePM12 ePM15 IMEC15 ePM 12 ePM 15

Replaces Part Numbers

022-000383-00 115-018012-00 115-018014-00 LI131001A LI13I001A Li31001A

Technical Specifications

Voltage11.1V
Amp Hours4500mAh
Capacity4500mAh
Rate49.95Wh
Net Weight318g /11.22 oz
Gross Weight468g /16.51 oz
Approximate Weight468g /16.51 oz
Dimension 147.50 x 60.50 x 23.70mm

Product Highlights

  • Brand: Mindray
  • Manufacturer: CS
  • Series: Standard
  • Color: Black
  • Product Type: Li-ion
  • Battery Type: Li-ion
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

The monitor won't power on after the replacement battery sat in the warehouse — is the cell dead?

It is not dead, but self-discharge during storage can drop the cell below the BMS recovery threshold, and the iMEC series will refuse to boot from a cell below approximately 9V. Connect the monitor to mains power and leave it on charge for a minimum of four hours before attempting to power on from battery alone. The charge IC will trickle-charge the cell back above the recovery threshold, and normal boot will follow. Check that the charge indicator light is active — if it is not, the cell is below trickle-charge entry voltage and needs a longer mains session.

The iMEC8 shuts off unexpectedly during patient monitoring even though the battery showed adequate charge before the shift started.

New Li-ion cells have higher internal resistance in the first ten cycles, which causes voltage sag under the continuous load the iMEC8 draws across its sensors and display. The BMS interprets that voltage sag as a low-cell-voltage event and triggers a protective shutdown before the cell is actually depleted. Run three to five full charge-discharge cycles in a controlled environment — not on an active patient — before relying on this battery for extended monitoring shifts. After those break-in cycles, internal resistance drops and the voltage sag under load normalises.

The monitor's self-test fails with a battery error after the swap, but the cell charged fully.

The BMS learn cycle has not completed yet. The iMEC and iPM series require one full charge-discharge sequence before the BMS can validate the new cell's capacity against its internal acceptance criteria. A self-test run before that cycle is complete will return a battery fault even on a functional cell. Discharge the monitor to automatic shutdown on battery, then charge uninterrupted to 100% — at that point, rerun the self-test and the error will clear.