ZTE U950 Li-Polymer Compatible Battery 3.7V 2000mAh
This product ships directly from our Manufacturer's Warehouse and is usually delivered within 7 – 10 business days to your doorstep.
WECARE5
Check that your old battery model number and device model to match our description. This makes sure they work together.
We ship your order same day if you buy it before 4 PM EST.
ZTE U950 Li-Polymer Compatible Battery 3.7V 2000mAh - is backordered and will ship as soon as it is back in stock.
Let customers speak for us
Send Your Battery Photo
Expert Technician Help
Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.
POST YOUR BATTERY IMAGE
Product & Solutions Expert
✉ sales@batteryweb.com
Battery Care Tips
Battery Care Tips
🔹 Getting Started
Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.
🔹 Keep It Healthy
Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.
Delivery and Shipping
Delivery and Shipping
🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.
Disclaimer
Disclaimer
⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.
🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.
ZTE U950 Li-Polymer Compatible Battery 3.7V 2000mAh - is backordered and will ship as soon as it is back in stock.
Voltage
3.7V
Amp
2000mAh
ZTE U950 / V955 / U960S3 — 3.7V Li-Polymer Replacement Battery (Li3720T42P3h585651)
This is a 3.7V, 2000mAh Li-Polymer cell built to the Li3720T42P3h585651 specification. It fits the ZTE U950, V955, U960S3, and N880G, among others in the same platform family. The cell measures 57 × 54 × 4mm — match your original before installation.
- U950 / V955 platform fit: These models share the same battery bay dimensions, connector pinout, and BMS handshake protocol. One cell covers the full group without modification.
- Bench tested on actual hardware: We cycled this cell through charge and discharge on the U950 platform. The BMS accepted the cell, charge termination triggered correctly at 4.2V, and the protection circuit held cutoff at the expected low-voltage threshold without tripping prematurely.
- Fuel gauge recalibration on first use: On first use after installation, disable fast charging for one full discharge-charge cycle. The fuel gauge IC is calibrated to the old cell's discharge curve. Running one slow cycle lets it recalibrate against the new cell before high-current charging pushes current into an uncalibrated state.
Sudden shutdown at 20–30% on the ZTE U950 after a cell swap
The U950's fuel gauge IC stores a learned discharge curve from the original cell. When a new cell goes in, that curve no longer matches the actual voltage drop under load. The modem and display draw a combined spike that causes the cell voltage to dip below the BMS cutoff threshold even while the OS still reports 20–30% remaining. The phone interprets this as a hard fault and shuts down. One full slow discharge-charge cycle forces the coulomb counter to relearn the new cell's actual capacity curve and corrects the shutdown behaviour.
Phone shows wrong battery percentage after replacement
The OS percentage display is driven by the fuel gauge IC, not a direct voltage reading. After a cell swap, the IC is still mapping charge state against the old cell's impedance and self-discharge profile. This causes percentage figures to jump, stall, or freeze at values like 99% or drop suddenly. Drain the phone until it shuts off, then charge uninterrupted to 100% on a standard 5V charger — this resets the coulomb counter and re-anchors the gauge to the new cell's actual endpoints.
Compatible Models
Replaces Part Numbers
Technical Specifications
Product Highlights
- Brand: ZTE
- Manufacturer: CS
- Series: X-Longer
- Color: Black
- Product Type: Li-Polymer
- Battery Type: Li-Polymer
- Warranty: 12 Months
- Bulk Orders: sales@batteryweb.com
Frequently Asked Questions
My ZTE U950 won't turn on at all after the replacement battery sat in a drawer for months — is the cell dead?
It's likely a BMS lockout. Li-Polymer cells that drop below roughly 2.5V per cell in storage trigger a protection circuit that blocks current flow entirely to prevent thermal runaway. The phone won't respond to the power button or show a charging indicator. Connect it to a 5V wall charger — not a PC USB port — and leave it for 20–30 minutes without pressing anything. The BMS needs a trickle current to recover voltage above the lockout threshold before normal charging can resume.
Fast charging stopped working on my ZTE U950 the first time I plugged in the new battery — was it working before?
Yes, this is a known first-cycle behaviour. The USB charging negotiation protocol on the U950 depends partly on the BMS recognising the cell as fully initialised. On the first connection, some replacement cells present a slightly higher internal impedance, and the charge IC defaults to standard 5V current rather than negotiating the higher rate. Run one full standard-rate charge cycle to completion. On the second cycle, fast charging typically resumes once the BMS and charge IC have exchanged a complete handshake at the new cell's impedance level.
My ZTE U950 feels warm near the battery area while charging the new cell — is that normal?
A new Li-Polymer cell has slightly higher internal impedance than a broken-in cell, which generates more heat during the initial charge cycles as the charge IC pushes current against that resistance. This typically reduces after two or three full cycles as the cell's impedance settles. If the device stays warm well into the constant-voltage phase — past roughly 4.1V — or gets uncomfortably hot to hold, stop charging and check that the connector is fully seated, as a partial connection increases resistance at the contact point.