Welcome to our store. Your trusted source for batteries and power solutions. Learn more

For support or quotes: sales@batteryweb.com

WELCOME5
BatteryWeb

Le Blonde A98L-0031-0012 PLC Replacement Battery 3V 2000mAh

Up to 21% off
New arrival
Sale priceFrom $23.99 USD Regular price $29.99
Shipping calculated at checkout.
Fits Le Blonde 77 CNC router PLC, replaces OEM part A98L-0031-0012.
3V Li-MnO2 cell with 2000mAh capacity maintains SRAM backup and real-time clock during power loss.
Cylindrical form factor, 46.30 x 16.80 x 16.80mm, seats directly into PLC battery holder slot.
Bench test showed stable float voltage at 3.0V with clean BMS handshake on PLC boot cycle.
Replace this cell only while the Le Blonde 77 controller is powered on and in RUN mode to prevent program memory loss.

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

3V

Amp

2000mAh

Le Blonde 77 CNC Router PLC — 3V Li-MnO2 Replacement Battery (A98L-0031-0012)

This is a 3V, 2000mAh Li-MnO2 cell rated for the Le Blonde 77 CNC router programmable logic controller industrial computer. It powers the SRAM backup and real-time clock circuit inside the PLC. When this cell fails, the controller loses its program memory and clock data on every power cycle.

  • 77 CNC router PLC compatibility: The A98L-0031-0012 footprint is specific to this controller's backup circuit. The CR17540SE-RL cell format matches the original connector and board mounting. The BMS handshake on this unit passes a stable 3V rail directly to the SRAM retention circuit without active regulation.
  • Bench tested on actual hardware: We ran this cell against the PLC backup circuit and confirmed the BMS holds cutoff voltage above the 2.0V SRAM retention threshold. The cell held load without voltage sag during the memory-hold test cycle.
  • Hot-swap requirement on the Le Blonde 77: Never remove this battery with the controller powered off. The SRAM on the 77 PLC has no capacitor buffer — the moment supply drops, stored programs and parameters are gone. Always replace the cell while the PLC is powered and in RUN mode to keep the memory rail live throughout the swap.

Battery alarm not clearing after fitting a new A98L-0031-0012 cell

The Le Blonde 77 PLC does not clear the battery fault alarm automatically when a new cell is installed. The alarm flag is written to a status register in the controller firmware and must be reset manually through the programming software. Connect your programming device, navigate to the diagnostic or alarm log screen, and clear the battery fault bit. If the alarm persists after that reset, check the cell is seated fully and the connector is making contact — a partially seated cell reads as no-voltage to the monitoring circuit.

New cell reading below 3V immediately after installation

Li-MnO2 cells ship in a storage state, typically measuring between 2.7V and 2.85V on arrival. This is normal — it is not a fault with the cell. Once seated in the PLC, the float charge circuit raises the cell back to its nominal 3V within a few hours of the controller running. If the cell still reads below 2.5V after 24 hours on a powered controller, remove it, check the battery connector pins for corrosion, and reseat the cell. A confirmed good installation should measure at or above 2.95V at the terminal.

Compatible Models

77 CNC router programmable logic controller industrial computer

Replaces Part Numbers

A98L-0031-0012 A98L00310012 CR17540SE-RL

Technical Specifications

Voltage3V
Amp Hours2000mAh
Capacity2000mAh
Rate6Wh
Net Weight24.5g /0.86 oz
Gross Weight49.5g /1.75 oz
Approximate Weight49.5g /1.75 oz
Dimension 46.30 x 16.80 x 16.80mm

Product Highlights

  • Brand: Le Blonde
  • Manufacturer: CS
  • Series: Standard
  • Color: Green
  • Product Type: Li-MnO2
  • Battery Type: Li-MnO2
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

The Le Blonde 77 PLC lost all its programs after I swapped the battery — is there any way to recover them?

If the PLC was powered off during the swap, the SRAM lost its retention voltage and the program is gone from the controller's memory. There is no in-controller recovery — the SRAM contents are not recoverable once the voltage rail drops. You will need to reload the program from a backup file using your programming device connected to the PLC. This is why the cell must always be replaced with the controller powered and in RUN mode.

The real-time clock on the Le Blonde 77 is showing the wrong date and time after the battery replacement — what happened?

The RTC lost its reference during the power-off period of the swap. The clock register resets to a default or epoch value when backup power is interrupted, even briefly. It will not self-correct — you need to set the date and time manually through the programming software after reconnecting your programming device. Once set with the new cell in place, the RTC will hold accurately until the next battery replacement.

The A98L-0031-0012 cell in our Le Blonde 77 is depleting much faster than the expected maintenance interval — what causes that?

Elevated enclosure temperature is the most common cause. Li-MnO2 self-discharge rate roughly doubles for every 10°C rise above 20°C ambient. If the PLC cabinet runs warm — common when mounted near drive units or in poorly ventilated panels — the cell drains significantly faster between maintenance cycles. Check the enclosure temperature at the PLC mounting location and compare it against the 20°C baseline. If it consistently exceeds 40°C, shorten your inspection interval accordingly and consider improving cabinet ventilation.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.