Fits Lexus IS200 and IS300 siren alarm systems; replaces OEM part 28AAAM6BML.
7.2V at 300mAh capacity supplies backup power to trigger alarm during electrical interruption.
Connector slides into the siren housing slot with a single locking tab engagement.
We bench-tested the pack on a simulated alarm panel load; BMS discharged cleanly without cutoff faults.
After installation, close the siren cover fully and confirm the tamper switch engages — unclosed covers trigger false tamper faults on some panels.
Delivery time

This product ships directly from our Manufacturer’s Warehouse and is usually delivered within 5 – 8 business days to your doorstep.

Discount: As a thank you for your patience, enjoy 5% off on your order
WECARE5

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

7.2V

Amp

300mAh

LEXUS IS200 / IS300 Siren — 7.2V Ni-MH Replacement Battery (28AAAM6BML)

This is a 7.2V, 300mAh Ni-MH rechargeable battery for the LEXUS IS200 and IS300 factory alarm siren unit. It fits OEM siren part numbers 89040-53011 and 89040-53012. The siren draws on this cell to sound the alarm when the vehicle's main battery is disconnected or interrupted.

  • IS200 and IS300 siren compatibility: Both models use the same siren housing and OEM part reference 28AAAM6BML. The connector, cell count, and voltage rail are identical across these two variants, so one replacement covers both.
  • Bench tested on actual hardware: We cycled this cell through charge and discharge on a matched siren unit. The BMS accepted the full charge cycle without cutoff errors, and the cell held voltage within spec across the test window.
  • Siren cover and tamper switch check: After fitting the battery, close the siren cover fully and confirm the tamper switch is physically engaged. If the cover is not fully latched, many alarm panels will flag a tamper fault — and some interpret that as a battery fault, not a housing issue.

Why the IS200 siren stops sounding mid-alarm after a battery swap

A freshly installed Ni-MH cell may not hold the current draw required to sustain the siren's output for a full alarm cycle. Ni-MH cells ship at a partial state of charge and need at least one full charge before they can deliver consistent current. If the alarm triggers before the battery has charged, the cell voltage sags under load and the siren cuts out early. Allow the vehicle's alarm system to charge the siren battery for 24 hours before testing — the siren should then sustain output to at least 6.5V under load.

Siren battery voltage reading low after six months without a triggered alarm

Ni-MH cells self-discharge at a higher rate than Li-ion, typically losing 1–3% capacity per day at room temperature. Outdoor siren enclosures accelerate this — thermal cycling between cold nights and warm days increases the discharge rate further. A siren battery that sits untested through a full winter can drop below the minimum activation threshold without any fault ever showing on the panel. If the battery reads below 6.0V on a multimeter with the cell removed, refit and allow 48 hours of trickle charge before the next alarm test.

Compatible Models

IS200 IS300 Siren 89040-53011 89040-53012 IS200 Siren

Replaces Part Numbers

28AAAM6BML

Technical Specifications

Voltage7.2V
Amp Hours300mAh
Capacity300mAh
Rate2.16Wh
Net Weight41g /1.45 oz
Gross Weight66g /2.33 oz
Approximate Weight66g /2.33 oz
Dimension 61.90 x 31.20 x 10.50mm

Product Highlights

  • Brand: LEXUS
  • Manufacturer: CS
  • Series: Standard
  • Color: Green
  • Product Type: Ni-MH
  • Battery Type: Ni-MH
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

The IS200 siren isn't making any sound during the alarm test — I just put the new battery in yesterday. What's wrong?

A new Ni-MH cell ships partially discharged and needs a full charge cycle before it can sustain the current draw the siren requires. The alarm panel may have triggered the siren before the battery reached minimum threshold, causing the cell to cut out under load. Leave the vehicle with the alarm system armed for 24 hours to allow the siren battery to charge via the vehicle's trickle feed. After that, retest — the siren should sound at full volume without cutting out.

My alarm panel is showing a tamper fault right after I replaced the siren battery — I didn't touch the tamper switch. What's causing it?

The tamper switch on the IS200 siren housing is triggered by the cover itself — if the lid isn't fully clicked into the locked position, the switch stays open and the panel logs it as a tamper event. Some panels then flag this as a battery fault rather than a housing fault, which makes the diagnosis confusing. Remove the siren cover, reseat the battery, and refit the cover until you hear or feel it latch. Check the panel again — the tamper fault should clear within one poll cycle.

The siren battery keeps going flat between annual tests, even though the car is used regularly. Why does this keep happening?

Ni-MH cells self-discharge continuously, even when the siren is not triggered. Outdoor siren enclosures experience temperature swings that accelerate this — cold nights followed by warm days push the discharge rate well above the lab spec. A cell that is never triggered can still fall below the activation threshold within a few months. To keep the battery above minimum voltage between annual tests, trigger a short manual alarm test every two to three months — this prompts the vehicle's alarm system to top up the siren battery via its trickle charge circuit.