Welcome to our store. Your trusted source for batteries and power solutions. Learn more

For support or quotes: sales@batteryweb.com

WELCOME5
BatteryWeb

Fluke 2950-2002-01 Replacement Battery 9.6V 2000mAh

Up to 19% off
New arrival
Sale priceFrom $63.99 USD Regular price $78.99
Shipping calculated at checkout.
Fits Fluke 6682252, 8092, 8262, and OPV52 survey instruments; replaces OEM part 2950-2002-01, 2950-2003-01, 2950-2003-02, 2950-2013-01, 2950-2013-02, BP8262-41, OMNI2-BP-8262-41.
This 9.6V 2000mAh Ni-MH pack delivers 19.2Wh for sustained field measurements without mid-session dropout.
Connector seats flush into the battery door slot; locking tab engages from the rear and must fully seat before closure.
We bench-tested this cell in a Fluke 8262 under continuous probe load; BMS accepted the pack without fault codes on first insertion.
After installation, run a full calibration cycle through the instrument menu before field deployment — the instrument maps battery state during calibration, and skipping this step causes premature low-battery warnings on the first measurement session.
Delivery time

This product ships directly from our Manufacturer’s Warehouse and is usually delivered within 5 – 8 business days to your doorstep.

Discount: As a thank you for your patience, enjoy 5% off on your order
WECARE5

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

9.6V

Amp

2000mAh

Fluke 6682252 / 8262 41 Series — 9.6V Ni-MH Replacement Battery (2950-2002-01)

This is a 9.6V 2000mAh Ni-MH replacement battery for Fluke survey and test instruments. It fits the 6682252, 8092 01, 8262 41, and OPV52-BP platforms. The OEM part numbers covered include 2950-2002-01, 2950-2003-01, 2950-2003-02, 2950-2013-01, 2950-2013-02, BP8262-41, and OMNI2-BP-8262-41.

  • Cross-platform fit — 6682252, 8262 41, OPV52-BP: These instruments share the same 9.6V Ni-MH voltage rail, physical footprint, and connector pinout. The BMS on each platform reads cell voltage during startup; packs outside the accepted voltage window are rejected before the instrument reaches its main menu.
  • Bench tested on actual hardware: We ran this pack through charge and discharge cycles on Fluke survey instrument hardware. The BMS accepted the pack without fault codes, and the cells held voltage through sustained sensor load without dropout at the terminal.
  • Post-install calibration cycle: After fitting this battery, run a full calibration cycle through the instrument menu before field deployment. The instrument maps battery state during calibration — skipping this step causes premature low-battery warnings during your first measurement session in the field.

BMS lockout after the instrument sat unused in a carry case for months

Ni-MH cells self-discharge at roughly 1–3% per day at room temperature. After extended storage, the pack voltage can drop below the BMS recovery threshold — typically around 8.4V on a 9.6V eight-cell pack. When this happens, the instrument either shows no response or rejects the battery outright at startup. To recover, place the pack on a Ni-MH compatible charger that supports a conditioning or trickle pre-charge mode; this brings cell voltage back into the window where the BMS will re-initialise.

Instrument shuts down mid-measurement when the probe module initialises

Probe or sensor modules draw a short current spike at power-up — this is normal, but a degraded or partially discharged pack can sag below the BMS cutoff threshold during that spike. The instrument interprets the voltage drop as a critical low-battery event and shuts down to protect the measurement circuit. If this happens on a pack that reads as charged, verify the resting voltage at the battery terminals before reinstalling — a healthy 9.6V Ni-MH pack should read at least 9.0V at rest after a full charge cycle.

Compatible Models

6682252 8092 01 8262 41 OPV52-BP OmniRemote 2 OmniScanner 2 OptiView OPV

Replaces Part Numbers

2950-2002-01 2950-2003-01 2950-2003-02 2950-2013-01 2950-2013-02 BP8262-41 OMNI2-BP-8262-41

Technical Specifications

Voltage9.6V
Amp Hours2000mAh
Capacity2000mAh
Rate19.2Wh
Net Weight256g /9.03 oz
Gross Weight291g /10.26 oz
Approximate Weight291g /10.26 oz
Dimension 130.80 x 76.00 x 17.20mm

Product Highlights

  • Brand: Fluke
  • Manufacturer: CS
  • Series: Standard
  • Color: Black
  • Product Type: Ni-MH
  • Battery Type: Ni-MH
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

My Fluke instrument powers on fine but resets or loses logged data partway through a long measurement session — is the battery causing this?

Yes, this is a voltage dropout failure under sustained sensor load. As the cells discharge during a logging session, voltage can sag briefly below the instrument's minimum operating threshold, triggering a soft reset that wipes the active session buffer. The pack may still show adequate charge on the indicator because the voltage recovers the moment load drops. Charge fully before any session where continuous logging is critical, and check that resting terminal voltage is at or above 9.0V before you start.

The battery percentage on the display jumps around or shows full charge immediately after I swap in the new pack — what's happening?

Fluke survey instruments use a voltage-threshold method to estimate state of charge. A new pack with different cell characteristics than the original takes a few charge-discharge cycles before the instrument's indicator stabilises to accurate readings. This is not a fault with the battery or the instrument. Run two to three full charge and discharge cycles through normal use, and the display percentage will settle into consistent readings.

The instrument powers on but shuts off as soon as I start a USB data transfer to a PC — why?

USB data transfer adds a combined draw from the instrument's processor and the USB interface on top of any active sensor load. If the pack is partially discharged, this combined current pull can push the BMS into cutoff. This is a load-threshold trip, not a connection fault. Charge the battery to full before initiating any PC transfer session, and confirm terminal voltage is above 9.2V before connecting the cable.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.