Fits JDSU OLP-82P optical power meter and replaces OEM part FITP-RBP2.
3.7V, 5400mAh cell delivers 19.98Wh for sustained field measurements without mid-session shutdowns.
Connector seats straight into the handheld battery compartment with side-locking tab — confirm click before field deployment.
Bench testing showed stable voltage delivery under continuous probe load; BMS accepted first charge without cutoff delay.
After installation, run a full calibration cycle through the instrument menu before field deployment — the OLP-82P maps battery state during calibration, and skipping this step causes premature low-battery warnings on the first measurement session.
Delivery time

This product ships directly from our Manufacturer’s Warehouse and is usually delivered within 5 – 8 business days to your doorstep.

Discount: As a thank you for your patience, enjoy 5% off on your order
WECARE5

Visa Mastercard American Express PayPal Apple Pay Google Pay Shop Pay Discover Klarna Afterpay Stripe

Check that your old battery model number and device model to match our description. This makes sure they work together.


We ship your order same day if you buy it before 4 PM EST.

Warranty

Send Your Battery Photo

Expert Technician Help

Snap a photo or video of your battery and send it to us. We'll identify the exact replacement—fast and hassle-free. Our team has helped thousands of customers find the right battery quickly and easily.

POST YOUR BATTERY IMAGE
Product & Solutions Expert

Product & Solutions Expert

✉ sales@batteryweb.com

🔹 10+ Years Battery Experience 🔹 Fast & Accurate Identification

Battery Care Tips

🔹 Getting Started

Charge your new battery fully before you use it for the first time. Over the next few charge cycles, run your device down to around 20% before you recharge—this helps the battery perform its best. After that, charge whenever you need to.

🔹 Keep It Healthy

Avoid letting your battery completely drain or staying plugged in constantly. Both extremes wear it out faster. Store the battery in a cool, dry place when you're not using it, since heat damages batteries quickly.

Delivery and Shipping

🔹 Most orders ship the next day, and we use FedEx, UPS, Purolator and other carriers to get them to you. Lithium batteries have to ship by ground only, not air or USPS. Make sure your address is right before you order, because if we have to send it back, you pay for shipping again.

Disclaimer

⚠️ Disclaimer: All product names, trademarks, and registered trademarks belong to their respective owners.

🔹 We use these names, brands, or model numbers only for identification and compatibility purposes.


Voltage

3.7V

Amp

5400mAh

VIAVI JDSU OLP-82P — 3.7V Li-ion Replacement Battery (FITP-RBP2)

This is a 3.7V Li-ion battery rated at 5400mAh (19.98Wh), built to the FITP-RBP2 specification. It fits the JDSU OLP-82P optical power meter — a handheld instrument used by fiber optic technicians to measure signal loss and optical levels in the field. Connector orientation and BMS handshake match the original pack.

  • OLP-82P platform fit: The OLP-82P draws steady low current during measurements but spikes briefly when the optical detector module initialises at power-on. This pack's BMS is rated to absorb that inrush without triggering an overcurrent cutoff — a fault that can look like a dead battery even with a full charge.
  • Bench tested on actual hardware: We ran this pack through repeated power cycles on the OLP-82P, including back-to-back detector initialisations and sustained logging sessions. The BMS held stable across all cycles with no false cutoff events.
  • Post-install calibration on the OLP-82P: After fitting this pack, run a full calibration cycle through the instrument menu before field deployment. The OLP-82P maps battery state during calibration — skipping this step causes premature low-battery warnings to fire during your first measurement session even when the pack has significant capacity remaining.

OLP-82P shutting down mid-measurement despite showing adequate charge

The OLP-82P's optical detector draws a short current spike each time it re-initialises — this happens automatically during continuous logging sessions when the instrument re-syncs to a reference wavelength. If the cell voltage has sagged slightly under sustained load, that spike can push the BMS past its cutoff threshold even though the display shows remaining charge. The instrument cuts power as a protection response, not because the battery is empty. A pack with higher internal resistance — typical in aged cells — hits this threshold faster. This FITP-RBP2 replacement carries a fresh cell with lower internal resistance, which keeps voltage sag within tolerance during those re-initialisation events.

New pack won't charge after the OLP-82P sat unused for several months

Li-ion cells that sit below approximately 2.5V enter a deep-discharge state where the BMS locks out standard charge current as a safety measure. The OLP-82P charger sees the locked BMS and does nothing — the charge LED may not even light. Most chargers for this instrument do not apply a recovery pre-charge pulse automatically. To recover the pack, connect it to the charger and leave it undisturbed for 20–30 minutes; some chargers trickle a small recovery current that gradually brings cell voltage above the 2.5V re-enable threshold. If the LED remains off after 30 minutes, check that the charger output is delivering at least 4.2V at the connector before assuming the pack is faulty.

Compatible Models

JDSU OLP-82P

Replaces Part Numbers

FITP-RBP2

Technical Specifications

Voltage3.7V
Amp Hours5400mAh
Capacity5400mAh
Rate19.98Wh
Gross Weight250g /8.82 oz
Approximate Weight250g /8.82 oz

Product Highlights

  • Brand: VIAVI
  • Manufacturer: CS
  • Color: Black
  • Product Type: Li-ion
  • Battery Type: Li-ion
  • Warranty: 12 Months
  • Bulk Orders: sales@batteryweb.com

Frequently Asked Questions

The OLP-82P powers on fine but shuts itself off the moment I start a USB data transfer to my laptop — is this a battery issue or a port issue?

This is a battery issue. USB data transfer adds a combined draw — the instrument's processor, display, and USB controller all run simultaneously — and if the cell voltage sags under that load, the BMS trips and cuts power before the transfer completes. The OLP-82P does not have a separate USB power rail; everything runs off the battery. Fit a fresh pack and confirm the cell voltage holds above 3.6V under load before attempting another transfer.

My OLP-82P shows a full battery on the display but the reading resets and the screen flickers partway through a logging session — what's causing that?

That flicker and reset is a voltage dropout event, not a display fault. During a sustained logging session, continuous detector sampling draws enough current to dip the cell voltage momentarily — if the cell has any capacity fade, that dip crosses the instrument's reset threshold. The display percentage is calculated from a stored voltage map, so it can show "full" right up until the dropout. Replace the pack and run the OLP-82P's calibration cycle from the instrument menu so it re-maps the battery state curve to the new cell's characteristics.

After installing the new battery, the OLP-82P's charge indicator jumps around between percentages every time I reboot — is the pack defective?

The pack is not defective. The OLP-82P calculates state-of-charge by comparing measured cell voltage against a reference table that was calibrated to the previous pack's discharge curve. A new cell with a different internal resistance profile reads slightly differently at each voltage step, so the percentage indicator appears inconsistent until the instrument recalibrates. Run at least one full discharge-to-charge cycle through the instrument and then perform the calibration routine in the settings menu — after that cycle the displayed percentage will stabilise against the new cell's actual curve.